132L9717
Danfoss 132L9717 - VACON 100 INDUSTRIAL (37 kW / 50 HP, IP21, 380-500V)
- Frequency converter
- VACON 100 Industrial
- 380-500 Vac 72 AmpIP21/NEMA1
- Graphical Keypad MK01
- C2 Commercial&Industry Environ
- B Slot: F4,2 Relay board with therm
- C Slot: No board
- D Slot: No board
- E Slot: No board
- Fieldbus: Std protocol,Modbus,N2,BacNet
- Manual: Italian
- Frame 07
Model code:
VACON0100-3L-0072-5+SBF4+DBIN+DPAP+DLIT
VACON0100-3L-0072-5+SBF4+DBIN+DPAP+DLIT
Product details
| Segment | NONE | VACON 100 Industrial |
| Mains voltage | -5 | 380-500 Vac |
| Current rating | -0072 | 72 Amp |
| Installation options | -DM | DM Drive Module |
| Enclosure | +IP21 | IP21/NEMA1 |
| Control panel | +HMGR | Graphical Keypad MK01 |
| EMC emission limit category | +EMC2 | C2 Commercial&Industry Environ |
| Common mode filter (for DM) | +P000 | No Option |
| DUT filter (for DM) | +P000 | No Option |
| Brake chopper | +DBIN | Integrated Brake Chopper |
| Real time clock option | +SRNO | No Battery for real time clock |
| Configurable power range | NONE | None |
| Power connections | +P000 | No Power options (+P000) |
| Cable entry | +QGLM | Metric conduit plate |
| Additional Equipment B | +Q000 | No option for Qxxx_B (+Q000) |
| Additonal Equipment C | +Q000 | No additonal option for Qxxx_C |
| Shipping package | +GSCB | Cardboard Box as Shipping pack |
| Marine construction | +E000 | no option |
| B-Slot Option Board | +SBF4 | F4,2 Relay board with therm |
| C- Slot Option Board | +SC00 | No board |
| D-Slot Option Board | +SD00 | No board |
| E-Slot Option Board | +SE00 | No board |
| Internal FB selection | +FBM1 | Std protocol,Modbus,N2,BacNet |
| Documentation level | +DPAP | Paper Manuals |
| Document language preference | +DLIT | Italian |
| Firmware Language Pack | +FL01 | UK, DE, FI, SE, IT, FR lang |
| Application | +A0000 | No Application |
| Parameter Set | +L0000 | No application parameter set |
| Motor parameter default freq | +LS50 | 50 Hz def motor freq settings |
| Unit for measure for display | +LSSI | Metric Units of Measure |
| Labeling options | +LPC1 | no additional labels |
| UL approval | +GAUL | UL Approval (+GAUL) |
| Marine approval | NONE | None |
| RCM Approval | +GACT | RCM Approval N16307 |
| KC approval | +GAKC | KC Approval |
| Ukrainian approval | +GAUA | Ukrainian Approval |
| EAC Approval | +GAEA | EAC Approval |
| Auxilary power supply | +C000 | no option |
| DC power supply for aux device | +C000 | no option |
| AC socket for aux devices | +C000 | no option |
| Input Devices | NONE | none_ |
| Common mode filter (for ED) | +P000 | no option |
| DU/DT, Sine filter (for ED) | +P000 | no option |
| Terminal Options | NONE | none_ |
| Door Equipments | +C000 | no option |
| Cabinet heater | +C000 | no option |
| Cabinet light | +C000 | no option |
| Motor heater control | +C000 | no option |
| Emergency stop options | +C000 | no option |
| Insulation fault sensor | +C000 | no option |
| Cabling from top | +C000 | no option |
| Back channel cooling | +C000 | no option |
| Cabinet Plinth | +C000 | no option |
| Empty extension segment | NONE | None |
| Standardized cabinet solution | NONE | None |
| Engineered cabinet solution | NONE | None |
| Product Group | VACON | |
| Product Series | 0100 | Vacon 100 series |
| Phase | -3L | 3 Phase AC Input |
| Customized | +BM26 | Vacon 100 |
| Main Circuit | +M000 | NONE |
| Firmware | +F0072 | Vacon0100 Software package |
| Max output frequency | NONE | None |
| Terminal Box | +T000 | NONE |
| Bypass Control Operation Mode | NONE | none_ |
| Bypass Input Type | NONE | none_ |
| Bypass power connection type | NONE | none_ |
| CE approval | +GACE | CE Approval (+GACE) |
| ATEX Approval | NONE | None |
| County Specific Approval | NONE | None |
| Warrenty time | +WT01 | Warranty 12/18 months (+WT01) |
| Frame Size | MR07 | Frame 07 |
| Motor Power Low Overload [kW] | 37 | |
| Motor Power High Overload [kW] | 30 | |
| Dimensions WxHxD [mm] net | 237 X 660 X 259 | |
| Dimensions WxHxD [mm] Gross | 310 X 740 X 310 | |
| Continuous Current (NO) [A] | 72 | |
| Continuous Current (HO) [A] | 61 | |
| Motor Power HP Low Overload | 50 | |
| Motor Power HP High Overload | 40 |
Technical data
| Motor power | 37 kW / 50 HP | |
| Mains voltage | 380-500 Vac | |
| Phase | Three-phase | |
| Protection rating | IP21/NEMA1 | |
| Frame size | MR07 | |
| RFI filter | Class A1 (EMC C2) | |
| Brake chopper | Yes | |
| Control panel | Graphical Keypad | |
| Mains option | None | |
| Fieldbus | Std protocol,Modbus,N2,BacNet | |
| Product type | Frequency converter | |
| Continuous output current | 72 A | |
| Continuous current (high overload) | 61 A | |
| Rated current | 72 A | |
| Power, high overload | 30 kW | |
| Power, low overload | 37 kW | |
| Height | 660 mm | |
| Width | 237 mm | |
| Depth | 259 mm | |
| Net weight | 37.5 kg | |
| Gross weight | 38.5 kg | |
| EAN | 5715253004136 | |
| ECCN (EU) | Y901 | |
| ECCN (US) | 3A999.a | |
Documents
Operating guides, design guides, certificates and CAD drawings for 132L9717 are available on request. Ask for documents →
Other 37 kW / 50 HP variants in VACON® 100 INDUSTRIAL
- 135N2258 IP21 · Class A1 · MR07
- 136Z6467 IP21 · Class A1 · MR07
- 137G6471 IP21 · Class A1 · MR07
- 135X4742 IP21 · Class A1 · MR07
- 136U2577 IP21 · Class A1 · MR07
- 132L9445 IP21 · Class A1 · MR07
- 137G3580 IP21 · Class A1 · MR07
- 136Z0677 IP21 · Class A1 · MR07
- 136Z6990 IP21 · Class A1 · MR07
- 136N1490 IP21 · Class A1 · MR07
- 132N4140 IP21 · Class A1 · MR07
- 132L9425 IP21 · Class A1 · MR07
- 136U0570 IP21 · Class A1 · MR07
- 137L6423 IP21 · Class A1 · MR07
- 136H9636 IP21 · Class A1 · MR07
- 132N7834 IP21 · Class A1 · MR07
- 136U7187 IP21 · Class A1 · MR07
- 136H5968 IP21 · Class A1 · MR07
- 136G6375 IP21 · Class A1 · MR07
- 136F9949 IP21 · Class A1 · MR07
- 135N0151 IP21 · Class A1 · MR07
- 136F3876 IP21 · Class A1 · MR07
- 136L7508 IP21 · Class A1 · MR07
- 137L1919 IP21 · Class A1 · MR07