135U3791
Danfoss 135U3791 - VACON 100 FLOW (3 kW / 4 HP, IP21, 208-240V)
- Frequency converter
- VACON 100 FLOW
- 208–240 Vac 12 AmpIP21/NEMA1
- Graphical Keypad MK01
- C2 Commercial&Industry Environ
- B Slot: F3,3 Relay board
- C Slot: No board
- D Slot: No board
- E Slot: No board
- Fieldbus: Std protocol,Modbus,N2,BacNet
- Manual: French
- Frame 04
Model code:
VACON0100-3L-0012-2-FLOW+DPAP+DLFR
VACON0100-3L-0012-2-FLOW+DPAP+DLFR
Product details
| Segment | -FLOW | VACON 100 FLOW |
| Mains voltage | -2 | 208–240 Vac |
| Current rating | -0012 | 12 Amp |
| Installation options | -DM | DM Drive Module |
| Enclosure | +IP21 | IP21/NEMA1 |
| Control panel | +HMGR | Graphical Keypad MK01 |
| EMC emission limit category | +EMC2 | C2 Commercial&Industry Environ |
| Common mode filter (for DM) | +P000 | No Option |
| DUT filter (for DM) | +P000 | No Option |
| Brake chopper | +DBNO | No dynamic braking device |
| Real time clock option | +SRNO | No Battery for real time clock |
| Configurable power range | NONE | None |
| Power connections | +P000 | No Power options (+P000) |
| Cable entry | +QGLM | Metric conduit plate |
| Additional Equipment B | +Q000 | No option for Qxxx_B (+Q000) |
| Additonal Equipment C | +Q000 | No additonal option for Qxxx_C |
| Shipping package | +GSCB | Cardboard Box as Shipping pack |
| Marine construction | +E000 | no option |
| B-Slot Option Board | +SBF3 | F3,3 Relay board |
| C- Slot Option Board | +SC00 | No board |
| D-Slot Option Board | +SD00 | No board |
| E-Slot Option Board | +SE00 | No board |
| Internal FB selection | +FBM1 | Std protocol,Modbus,N2,BacNet |
| Documentation level | +DPAP | Paper Manuals |
| Document language preference | +DLFR | French |
| Firmware Language Pack | +FL01 | UK, DE, FI, SE, IT, FR lang |
| Application | +A0000 | No Application |
| Parameter Set | +L0000 | No application parameter set |
| Motor parameter default freq | +LS50 | 50 Hz def motor freq settings |
| Unit for measure for display | +LSSI | Metric Units of Measure |
| Labeling options | +LPC1 | no additional labels |
| UL approval | +GAUL | UL Approval (+GAUL) |
| Marine approval | NONE | None |
| RCM Approval | +GACT | RCM Approval N16307 |
| KC approval | +GAKC | KC Approval |
| Ukrainian approval | +GAUA | Ukrainian Approval |
| EAC Approval | +GAEA | EAC Approval |
| Auxilary power supply | +C000 | no option |
| DC power supply for aux device | +C000 | no option |
| AC socket for aux devices | +C000 | no option |
| Input Devices | NONE | none_ |
| Common mode filter (for ED) | +P000 | no option |
| DU/DT, Sine filter (for ED) | +P000 | no option |
| Terminal Options | NONE | none_ |
| Door Equipments | +C000 | no option |
| Cabinet heater | +C000 | no option |
| Cabinet light | +C000 | no option |
| Motor heater control | +C000 | no option |
| Emergency stop options | +C000 | no option |
| Insulation fault sensor | +C000 | no option |
| Cabling from top | +C000 | no option |
| Back channel cooling | +C000 | no option |
| Cabinet Plinth | +C000 | no option |
| Empty extension segment | NONE | None |
| Standardized cabinet solution | NONE | None |
| Engineered cabinet solution | NONE | None |
| Product Group | VACON | |
| Product Series | 0100 | Vacon 100 series |
| Phase | -3L | 3 Phase AC Input |
| Customized | +BM2H | Vacon 100-FLOW |
| Main Circuit | +M000 | NONE |
| Firmware | +F0159 | Vacon0100-Flow Software pack |
| Max output frequency | NONE | None |
| Terminal Box | +T000 | NONE |
| Bypass Control Operation Mode | NONE | none_ |
| Bypass Input Type | NONE | none_ |
| Bypass power connection type | NONE | none_ |
| CE approval | +GACE | CE Approval (+GACE) |
| ATEX Approval | NONE | None |
| County Specific Approval | NONE | None |
| Warrenty time | +WT01 | Warranty 12/18 months (+WT01) |
| Frame Size | MR04 | Frame 04 |
| Motor Power Low Overload [kW] | 3 | |
| Dimensions WxHxD [mm] net | 128 X 328 X 190 | |
| Dimensions WxHxD [mm] Gross | 175 X 384 X 232 | |
| Dimensions WxHxD [mm] | 128X328X190 | |
| Continuous Current (NO) [A] | 12,5 | |
| Motor Power HP Low Overload | 4 |
Technical data
| Motor power | 3 kW / 4 HP | |
| Mains voltage | 208–240 Vac | |
| Phase | Three-phase | |
| Protection rating | IP21/NEMA1 | |
| Frame size | MR04 | |
| RFI filter | Class A1 (EMC C2) | |
| Brake chopper | No | |
| Control panel | Graphical Keypad | |
| Mains option | None | |
| Fieldbus | Std protocol,Modbus,N2,BacNet | |
| Product type | Frequency converter | |
| Continuous output current | 12.5 A | |
| Rated current | 12 A | |
| Power, low overload | 3 kW | |
| Height | 328 mm | |
| Width | 128 mm | |
| Depth | 190 mm | |
| Net weight | 6 kg | |
| Gross weight | 7 kg | |
| EAN | 5710108300470 | |
| ECCN (EU) | Y901 | |
| ECCN (US) | 3A999.a | |
Documents
Operating guides, design guides, certificates and CAD drawings for 135U3791 are available on request. Ask for documents →
Other 3 kW / 4 HP variants in VACON® 100 FLOW
- 135N4201 IP21 · Class A1 · MR04
- 132X2657 IP21 · Class A1 · MR04
- 137G0026 IP21 · Class A1 · MR04
- 136L7593 IP21 · None · MR04
- 136L2549 IP21 · Class A1 · MR04
- 135X0777 IP21 · Class A1 · MR04
- 132N0639 IP21 · Class A1 · MR04
- 136X2305 IP21 · Class A1 · MR04
- 137G9974 IP21 · Class A1 · MR04
- 136G5110 IP21 · Class A1 · MR04
- 136H4628 IP21 · Class A1 · MR04
- 135U4071 IP21 · Class A1 · MR04
- 136L7989 IP21 · Class A1 · MR04
- 137G1692 IP21 · Class A1 · MR04
- 136U3626 IP21 · Class A1 · MR04
- 135U1458 IP21 · None · MR04
- 135N4729 IP21 · None · MR04
- 136L1775 IP21 · None · MR04
- 132L0450 IP21 · Class A1 · MR04
- 136Z3519 IP21 · None · MR04
- 136G1405 IP54 · Class A1 · MR04
- 135U3808 IP54 · Class A1 · MR04
- 136N6271 IP54 · Class A1 · MR04
- 136L2718 IP54 · Class A1 · MR04