136F8090
Danfoss 136F8090 - VLT Refrigeration Drive FC 103 (1.1 kW / 1.5 HP, IP21, 525-600V)
- Frequency converter
- VLT® Refrigeration Drive FC-103
- 1.1 KW / 1.5 HP, Three phase
- 525 - 600 VAC, IP21 / Type 1
- No RFI filter
- No brake chopper
- Graphical Loc. Cont. Panel
- Not coated PCB, No Mains Option
- Latest release std. SW.
- AK-LonWorks MCA 107, No B Option
- No C1 option, No D option
- Frame: A3
Model code:
FC-103P1K1T6E21HXXGXXXXSXXXXAZBXCXXXXDX
FC-103P1K1T6E21HXXGXXXXSXXXXAZBXCXXXXDX
Product details
| Product Group | FC- | VLT® Refrigeration Drive |
| Series | 103 | |
| Power Rating | P1K1 | 1.1 KW / 1.5 HP |
| Phase | T | Three phase |
| Mains Voltage | 6 | 525 - 600 VAC |
| Enclosure | E21 | IP21 / Type 1 |
| RFI Filter | HX | No RFI filter |
| Brake - Safe Stop | X | No brake chopper |
| LCP | G | Graphical Loc. Cont. Panel |
| Coating PCB | X | Not coated PCB |
| Mains Option | X | No Mains Option |
| Adaptation A | X | Standard Cable Entries |
| Adaptation B | X | No adaptation |
| Software Release | SXXX | Latest release std. SW. |
| Software Language Pack | X | Standard Language Pack |
| A Option | AZ | AK-LonWorks MCA 107 |
| B Option | BX | No B Option |
| C0 Option MCO | CX | No C0 option |
| C1 Option | X | No C1 option |
| C Option Software | XX | No software option |
| D Option | DX | No D option |
| Frame Size | A3 | |
| Power 110% (NO) [KW] | 1.1 | |
| Height [mm] | 375,0 | |
| Width w/ no C options [mm] | 130,0 | |
| Width w/ two C options [mm] | 190,0 | |
| Depth [mm] | 207,0 | |
| Depth with Option A/B [mm] | 222,0 | |
| kVA | 2.39 | |
| Power Loss NO [W] | 50 | |
| Power Loss NO [W] | 50 | |
| Continuous Current (NO) [A] | 2.6 | |
| Intermittent Current (NO) [A] | 2.86 | |
| Continuous Current (NO) [A] | 2.4 | |
| Intermittent Current (NO) [A] | 2.64 |
Technical data
| Motor power | 1.1 kW / 1.5 HP | |
| Mains voltage | 525 - 600 VAC | |
| Phase | Three-phase | |
| Protection rating | IP21 / Type 1 | |
| Frame size | A3 | |
| RFI filter | None | |
| Brake chopper | No | |
| Control panel | Graphical LCP | |
| PCB coating | Uncoated | |
| Mains option | None | |
| Fieldbus | AK-LonWorks MCA 107 | |
| Product type | Frequency converter | |
| Continuous output current | 2.6 A | |
| Continuous current (high line) | 2.4 A | |
| Intermittent output current | 2.86 A | |
| Apparent power | 2.39 kVA | |
| Power loss | 50 W | |
| Power, normal overload | 1.1 kW | |
| Height | 375 mm | |
| Width | 130 mm | |
| Width with C options | 190 mm | |
| Depth | 207 mm | |
| Depth with A/B options | 222 mm | |
| Net weight | 6.5 kg | |
| Gross weight | 6.8 kg | |
| Packed volume | 0 L | |
| EAN | 5710108545246 | |
| ECCN (EU) | X.A.I.003 | |
| ECCN (US) | 3A999 | |
Documents
Operating guides, design guides, certificates and CAD drawings for 136F8090 are available on request. Ask for documents →
Other 1.1 kW / 1.5 HP variants in VLT® Refrigeration Drive FC 103
- 136F9053 IP20 · Class A1/B · A2
- 136N8085 IP20 · Class A1/B · A2
- 134F7350 IP20 · Class A1/B · A2
- 134F7345 IP20 · Class A1/B · A2
- 134H4859 IP20 · Class A1/B · A2
- 134G9202 IP20 · Class A1/B · A2
- 134H1650 IP20 · Class A1/B · A2
- 134F8447 IP20 · Class A1/B · A2
- 134U7083 IP20 · Class A1/B · A2
- 134H6475 IP20 · Class A1/B · A2
- 136H4580 IP20 · Class A1/B · A2
- 134G2331 IP20 · Class A1/B · A2
- 134N1423 IP20 · Class A2 · A2
- 135N1306 IP20 · Class A2 · A2
- 134G2967 IP20 · Class A2 · A2
- 134N0874 IP20 · Class A2 · A2
- 134F7346 IP20 · Class A2 · A2
- 134H5125 IP20 · Class A2 · A2
- 134G4611 IP20 · Class A2 · A2
- 134G5179 IP20 · Class A2 · A2
- 134G9783 IP20 · Class A2 · A2
- 136L0233 IP20 · Class A2 · A2
- 134F7997 IP20 · Class A2 · A2
- 135X5610 IP20 · Class A2 · A2