136H0804
Danfoss 136H0804 - VACON 100 FLOW Enclosed Drive (500 kW / 800 HP, IP21, 380-500V)
- Frequency converter
- VACON 100 FLOW
- 380-500 Vac 920 AmpIP21/NEMA1
- Graphical Keypad MK01
- C3 Commercial&Industry Environ
- B Slot: F3,3 Relay board
- C Slot: No board
- D Slot: No board
- E Slot: No board
- Fieldbus: Std protocol,Modbus,N2,BacNet
- Manual: English
- 2xFrame 10
Model code:
VACON0100-3L-0920-5-ED-FLOW+GNUL
VACON0100-3L-0920-5-ED-FLOW+GNUL
Product details
| Segment | -FLOW | VACON 100 FLOW |
| Mains voltage | -5 | 380-500 Vac |
| Current rating | -0920 | 920 Amp |
| Installation options | -ED | ED Enclosed Drive |
| Enclosure | +IP21 | IP21/NEMA1 |
| Control panel | +HMGR | Graphical Keypad MK01 |
| EMC emission limit category | +EMC3 | C3 Commercial&Industry Environ |
| Common mode filter (for DM) | +P000 | No Option |
| DUT filter (for DM) | +P000 | No Option |
| Brake chopper | +DBNO | No dynamic braking device |
| Real time clock option | +SRNO | No Battery for real time clock |
| Configurable power range | NONE | None |
| Power connections | +P000 | No Power options (+P000) |
| Cable entry | +Q000 | No option |
| Additional Equipment B | +Q000 | No option for Qxxx_B (+Q000) |
| Additonal Equipment C | +Q000 | No additonal option for Qxxx_C |
| Shipping package | +GSWP | Wooden box as shipping pack |
| Marine construction | +E000 | no option |
| B-Slot Option Board | +SBF3 | F3,3 Relay board |
| C- Slot Option Board | +SC00 | No board |
| D-Slot Option Board | +SD00 | No board |
| E-Slot Option Board | +SE00 | No board |
| Internal FB selection | +FBM1 | Std protocol,Modbus,N2,BacNet |
| Documentation level | +DPAP | Paper Manuals |
| Document language preference | +DLUK | English |
| Firmware Language Pack | +FL01 | UK, DE, FI, SE, IT, FR lang |
| Application | +A0000 | No Application |
| Parameter Set | +L0000 | No application parameter set |
| Motor parameter default freq | +LS50 | 50 Hz def motor freq settings |
| Unit for measure for display | +LSSI | Metric Units of Measure |
| Labeling options | +LPC1 | no additional labels |
| UL approval | +GNUL | No Ul Approval (+GNUL) |
| Marine approval | NONE | None |
| RCM Approval | +GACT | RCM Approval N16307 |
| KC approval | +GAKC | KC Approval |
| Ukrainian approval | +GAUA | Ukrainian Approval |
| EAC Approval | +GAEA | EAC Approval |
| Auxilary power supply | +C000 | no option |
| DC power supply for aux device | +C000 | no option |
| AC socket for aux devices | +C000 | no option |
| Input Devices | +CIFU | (+CIFU) AC fuses |
| Common mode filter (for ED) | +P000 | no option |
| DU/DT, Sine filter (for ED) | +P000 | no option |
| Terminal Options | +CTIO | I/O Terminals |
| Door Equipments | +C000 | no option |
| Cabinet heater | +C000 | no option |
| Cabinet light | +C000 | no option |
| Motor heater control | +C000 | no option |
| Emergency stop options | +C000 | no option |
| Insulation fault sensor | +C000 | no option |
| Cabling from top | +C000 | no option |
| Back channel cooling | +C000 | no option |
| Cabinet Plinth | +CHPL | Base plint 100 mm |
| Empty extension segment | NONE | None |
| Standardized cabinet solution | NONE | None |
| Engineered cabinet solution | NONE | None |
| Product Group | VACON | |
| Product Series | 0100 | Vacon 100 series |
| Phase | -3L | 3 Phase AC Input |
| Customized | +BM2H | Vacon 100-FLOW |
| Main Circuit | +M000 | NONE |
| Firmware | +F0159 | Vacon0100-Flow Software pack |
| Max output frequency | NONE | None |
| Terminal Box | +T000 | NONE |
| Bypass Control Operation Mode | NONE | none_ |
| Bypass Input Type | NONE | none_ |
| Bypass power connection type | NONE | none_ |
| CE approval | +GACE | CE Approval (+GACE) |
| ATEX Approval | NONE | None |
| County Specific Approval | NONE | None |
| Warrenty time | +WT01 | Warranty 12/18 months (+WT01) |
| Frame Size | MR12 | 2xFrame 10 |
| Motor Power Low Overload [kW] | 500 | |
| Dimensions WxHxD [mm] net | 1206 X 2155 X 639 | |
| Dimensions WxHxD [mm] Gross | 1355 X 2440 X 800 | |
| Dimensions WxHxD [mm] | 1212X2100X600 | |
| Continuous Current (NO) [A] | 920 | |
| Motor Power HP Low Overload | 800 | |
| Method | HORIZONTAL |
Technical data
| Motor power | 500 kW / 800 HP | |
| Mains voltage | 380-500 Vac | |
| Phase | Three-phase | |
| Protection rating | IP21/NEMA1 | |
| Frame size | MR12 | |
| RFI filter | Class A2 (EMC C3) | |
| Brake chopper | No | |
| Control panel | Graphical Keypad | |
| Mains option | Integrated Fuse | |
| Fieldbus | Std protocol,Modbus,N2,BacNet | |
| Product type | Enclosed drive | |
| Continuous output current | 920 A | |
| Rated current | 920 A | |
| Power, low overload | 500 kW | |
| Height | 2155 mm | |
| Width | 1206 mm | |
| Depth | 639 mm | |
| Net weight | 620.6 kg | |
| Gross weight | 621.6 kg | |
| EAN | 5710108673017 | |
| ECCN (EU) | Y901 | |
| ECCN (US) | 3A999.a | |
Documents
Operating guides, design guides, certificates and CAD drawings for 136H0804 are available on request. Ask for documents →
Other 500 kW / 800 HP variants in VACON® 100 FLOW Enclosed Drive
- 136N6975 IP21 · Class A2 · MR12
- 135X0937 IP21 · Class A2 · MR12
- 135U9033 IP21 · Class A2 · MR12
- 132X7763 IP21 · None · MR12
- 132X7380 IP21 · None · MR12
- 137N2936 IP21 · Class A2 · MR12
- 136Z5210 IP21 · Class A2 · MR12
- 132X4150 IP21 · Class A2 · MR12
- 136G5905 IP21 · Class A2 · MR12
- 132H4069 IP21 · Class A2 · MR12
- 137G1663 IP21 · Class A2 · MR12
- 136F8614 IP21 · None · MR12
- 136X0418 IP54 · Class A2 · MR12
- 136N7402 IP54 · Class A2 · MR12
- 136H3130 IP54 · Class A2 · MR12
- 136H0840 IP54 · Class A2 · MR12
- 136H3195 IP54 · Class A2 · MR12
- 136H3419 IP54 · Class A2 · MR12
- 137U1968 IP54 · Class A2 · MR12
- 132X1832 IP54 · Class A2 · MR12
- 132N5738 IP54 · Class A2 · MR12
- 137U9362 IP54 · None · MR12
- 132L9942 IP54 · Class A2 · MR12
- 136L4105 IP54 · Class A2 · MR12