136Z2981
Danfoss 136Z2981 - VACON 100 FLOW (200 kW / 300 HP, IP21, 380-500V)
- Frequency converter
- VACON 100 FLOW
- 380-500 Vac 386 AmpIP21/NEMA1
- Graphical Keypad MK01
- C3 Commercial&Industry Environ
- B Slot: F3,3 Relay board
- C Slot: No board
- D Slot: No board
- E Slot: No board
- Fieldbus: Std protocol,Modbus,N2,BacNet
- Manual: English
- Frame 09b
Model code:
VACON0100-3L-0386-5-FLOW
VACON0100-3L-0386-5-FLOW
Product details
| Segment | -FLOW | VACON 100 FLOW |
| Mains voltage | -5 | 380-500 Vac |
| Current rating | -0386 | 386 Amp |
| Installation options | -DM | DM Drive Module |
| Enclosure | +IP21 | IP21/NEMA1 |
| Control panel | +HMGR | Graphical Keypad MK01 |
| EMC emission limit category | +EMC3 | C3 Commercial&Industry Environ |
| Common mode filter (for DM) | +P000 | No Option |
| DUT filter (for DM) | +P000 | No Option |
| Brake chopper | +DBNO | No dynamic braking device |
| Real time clock option | +SRNO | No Battery for real time clock |
| Configurable power range | NONE | None |
| Power connections | +PA00 | OBS-No power options |
| Cable entry | +QGLM | Metric conduit plate |
| Additional Equipment B | +Q000 | No option for Qxxx_B (+Q000) |
| Additonal Equipment C | +Q000 | No additonal option for Qxxx_C |
| Shipping package | +GSCB | Cardboard Box as Shipping pack |
| Marine construction | +E000 | no option |
| B-Slot Option Board | +SBF3 | F3,3 Relay board |
| C- Slot Option Board | +SC00 | No board |
| D-Slot Option Board | +SD00 | No board |
| E-Slot Option Board | +SE00 | No board |
| Internal FB selection | +FBM1 | Std protocol,Modbus,N2,BacNet |
| Documentation level | +DQCK | Quick Guide |
| Document language preference | +DLUK | English |
| Firmware Language Pack | +FL01 | UK, DE, FI, SE, IT, FR lang |
| Application | +A0000 | No Application |
| Parameter Set | +L0000 | No application parameter set |
| Motor parameter default freq | +LS50 | 50 Hz def motor freq settings |
| Unit for measure for display | +LSSI | Metric Units of Measure |
| Labeling options | +LPC1 | no additional labels |
| UL approval | +GAUL | UL Approval (+GAUL) |
| Marine approval | NONE | None |
| RCM Approval | +GACT | RCM Approval N16307 |
| KC approval | +GAKC | KC Approval |
| Ukrainian approval | +GAUA | Ukrainian Approval |
| EAC Approval | +GAEA | EAC Approval |
| Auxilary power supply | +C000 | no option |
| DC power supply for aux device | +C000 | no option |
| AC socket for aux devices | +C000 | no option |
| Input Devices | NONE | none_ |
| Common mode filter (for ED) | +P000 | no option |
| DU/DT, Sine filter (for ED) | +P000 | no option |
| Terminal Options | NONE | none_ |
| Door Equipments | +C000 | no option |
| Cabinet heater | +C000 | no option |
| Cabinet light | +C000 | no option |
| Motor heater control | +C000 | no option |
| Emergency stop options | +C000 | no option |
| Insulation fault sensor | +C000 | no option |
| Cabling from top | +C000 | no option |
| Back channel cooling | +C000 | no option |
| Cabinet Plinth | +C000 | no option |
| Empty extension segment | NONE | None |
| Standardized cabinet solution | NONE | None |
| Engineered cabinet solution | NONE | None |
| Product Group | VACON | |
| Product Series | 0100 | Vacon 100 series |
| Phase | -3L | 3 Phase AC Input |
| Customized | +BM2H | Vacon 100-FLOW |
| Main Circuit | +M000 | NONE |
| Firmware | +F0159 | Vacon0100-Flow Software pack |
| Max output frequency | NONE | None |
| Terminal Box | +T000 | NONE |
| Bypass Control Operation Mode | NONE | none_ |
| Bypass Input Type | NONE | none_ |
| Bypass power connection type | NONE | none_ |
| CE approval | +GACE | CE Approval (+GACE) |
| ATEX Approval | NONE | None |
| County Specific Approval | NONE | None |
| Warrenty time | +WT01 | Warranty 12/18 months (+WT01) |
| Frame Size | MR09B | Frame 09b |
| Motor Power Low Overload [kW] | 200 | |
| Dimensions WxHxD [mm] net | 480 X 1150 X 365 | |
| Dimensions WxHxD [mm] Gross | 730 X 1310 X 570 | |
| Dimensions WxHxD [mm] | 480X1150X365 | |
| Continuous Current (NO) [A] | 385 | |
| Motor Power HP Low Overload | 300 |
Technical data
| Motor power | 200 kW / 300 HP | |
| Mains voltage | 380-500 Vac | |
| Phase | Three-phase | |
| Protection rating | IP21/NEMA1 | |
| Frame size | MR09B | |
| RFI filter | Class A2 (EMC C3) | |
| Brake chopper | No | |
| Control panel | Graphical Keypad | |
| Mains option | None | |
| Fieldbus | Std protocol,Modbus,N2,BacNet | |
| Product type | Frequency converter | |
| Continuous output current | 385 A | |
| Rated current | 386 A | |
| Power, low overload | 200 kW | |
| Height | 1150 mm | |
| Width | 480 mm | |
| Depth | 365 mm | |
| Net weight | 108 kg | |
| Gross weight | 109 kg | |
| EAN | 5714853218844 | |
| ECCN (EU) | Y901 | |
| ECCN (US) | 3A999.a | |
Documents
Operating guides, design guides, certificates and CAD drawings for 136Z2981 are available on request. Ask for documents →
Other 200 kW / 300 HP variants in VACON® 100 FLOW
- 135N1626 IP00 · Class A2 · MR10
- 136F6363 IP00 · Class A2 · MR10
- 137N6336 IP00 · None · MR10
- 135X0605 IP00 · Class A2 · MR10
- 135X7633 IP00 · Class A2 · MR10
- 136L3026 IP00 · Class A2 · MR10
- 135N0548 IP00 · Class A2 · MR10
- 136G8302 IP00 · Class A2 · MR10
- 136L9253 IP00 · Class A2 · MR10
- 135X0474 IP00 · Class A2 · MR10
- 136G0118 IP00 · Class A2 · MR10
- 136N2688 IP00 · Class A2 · MR10
- 135N8874 IP00 · Class A2 · MR10
- 136N5930 IP00 · Class A2 · MR10
- 132X0646 IP00 · Class A2 · MR10
- 136H4559 IP00 · Class A2 · MR10
- 136X0560 IP00 · Class A2 · MR10
- 135U9972 IP00 · Class A2 · MR10
- 135X3601 IP00 · Class A2 · MR10
- 136G7535 IP00 · Class A2 · MR10
- 136H9527 IP00 · Class A2 · MR10
- 132N7422 IP00 · Class A2 · MR10
- 136L6987 IP00 · Class A2 · MR10
- 136G9064 IP00 · Class A2 · MR10