137U4387
Danfoss 137U4387 - iC7-Marine System Modules (250 kW / 350 HP, IP00, 380-500V)
- iC7-Marine
- System module, liquid-cooled
- IP00/Open Type, Frame:IR10L
- Inverter module, INU, 380-500 V AC / 465-800 V DC,416 A
- EMC category: C4 category
- Control Panel 2.8 OPX20
- Standard I/O: I/O and Relay Option OC7C1
- Modbus TCP OS7MT
- Functional Safety: None, not upgradable
Model code:
IC7-60SLINB5-416AE00F4+AE10+AKFX+ANN1+AO20+BAMT+BDC1+BEXX+BF20+BGK1+BH25+BK15+CAM0+CBT0+CCC1+CDX0+CEX0+CFX0+DAMA+EGIN+EHEN+VBDN
IC7-60SLINB5-416AE00F4+AE10+AKFX+ANN1+AO20+BAMT+BDC1+BEXX+BF20+BGK1+BH25+BK15+CAM0+CBT0+CCC1+CDX0+CEX0+CFX0+DAMA+EGIN+EHEN+VBDN
Product details
| Product series | +DAMA | iC7-Marine |
| Product group | IC7-60 | iC7-60 |
| Product category | SL | System module, liquid-cooled |
| Product type | IN | Inverter module, INU |
| Mains voltage | B5 | 380-500 V AC / 465-800 V DC |
| Current rating | -416A | 416 A |
| Power rating | 250 | 250 kW/350 HP |
| Protection rating | E00 | IP00/Open Type |
| EMC category | F4 | C4 category |
| Integration unit | +AE10 | Standard, no filter |
| Mains input device | +AJXX | None |
| DC fuses and devices | +AKFX | DC bus fuses |
| Cooling circuit connector type | +ANN1 | Push-in connection |
| Cooling circuit hose length | +AO20 | 2.0 m (6 ft) |
| Marine construction | +AFXX | None |
| Extra environmental protection | +AGCX | Coated boards |
| Communication interface, X1/X2 | +BAMT | Modbus TCP OS7MT |
| Communication interface, X0 | +BBEL | Ethernet port, no protocol |
| Standard I/O | +BDC1 | I/O and Relay Option OC7C1 |
| Functional safety | +BEXX | None, not upgradable |
| Control panel | +BF20 | Control Panel 2.8 OPX20 |
| Control panel mounting type | +BGK1 | Flush mount |
| Control panel cable length | +BH25 | 2.5 m (8 ft) |
| Control unit cable length | +BK15 | 1.5 m (5 ft), Fiber |
| StarCoupler board cable length | +BLXX | None |
| Option slot A | +CAM0 | Encoder/Resolver Option OC7M0 |
| Option slot B | +CBT0 | Temperature Measurement OC7T0 |
| Option slot C | +CCC1 | I/O and Relay Option OC7C1 |
| Option slot D | +CDX0 | None |
| Option slot E | +CEX0 | None |
| Option slot F | +CFX0 | None |
| Option slot G | +CGXX | None, without mounting plate |
| Option slot H | +CHXX | None, without mounting plate |
| Option slot I | +CIXX | None, without mounting plate |
| Option slot J | +CJXX | None, without mounting plate |
| Language package | +EL01 | Global |
| Customer specific application | +DBXX | None |
| Additional drive features 1 | +DD1X | None |
| Additional drive features 2 | +DE2X | None |
| Additional drive features 3 | +DF3X | None |
| Additional drive features 4 | +DG4X | None |
| Additional drive features 5 | +DH5X | None |
| High speed enabled | +DI6X | No |
| Customization file package ID | +EAXXXXXX | No customization |
| Product software ID | +ECXXX | Latest released version |
| Technical documentation | +EGIN | Installation guide |
| Documentation language | +EHEN | English |
| Customer-specific label | +EJXX | None |
| Shipping package | +TACB | Cardboard box package |
| Product specific marine cert. | +VBDN | DNV |
| Frame designation | IR10L | |
| Main unit Width | 140MM/5.5IN | |
| Main unit Height | 1295MM/51IN | |
| Main unit Depth | 566MM/22.3IN | |
| AC voltage | 3X0-400/460/500VAC | |
| Continous current IH (1/5min) | 312A(500VAC) | |
| Continous current IL (1/5min) | 416A(500VAC) | |
| Cooling type | Liquid Cooled | |
| DC Bus current | 440A(675VDC) | |
| DC Bus voltage | 465-800VDC | |
| DC power | 297KW(675VDC) | |
| Enclosure rating | IP00 / OPEN TYPE | |
| Liquid temp. High Overload | 45°C/113°F | |
| Liquid temp. Low Overload | 45°C/113°F | |
| Liquid temp. Nominal load | 45°C/113°F | |
| Nominal AC current | 425A(500VAC) | |
| Output frequency | 0-599Hz | |
| Overload current IH (1/5min) | 360A(500VAC) | |
| Overload current IL (1/5min) | 458A(500V) | |
| Short circuit current rating | 100kA | |
| Start current Imax (3sec) | 624A | |
| Storage temperature | -40...70°C/-40...158°F | |
| Typical motor power PH2 (150%) | 200KW(500VAC) | |
| Typical motor power PL (110%) | 270KW(500VAC) |
Technical data
| Motor power | 250 kW / 350 HP | |
| Mains voltage | 380-500 V AC / 465-800 V DC | |
| Protection rating | IP00/Open Type | |
| Frame size | IR10L | |
| RFI filter | None (EMC C4) | |
| Control panel | Control Panel 2.8 (OPX20) | |
| PCB coating | Coated PCB | |
| Mains option | None | |
| Fieldbus | Modbus TCP OS7MT | |
| Product type | System module, liquid-cooled (Inverter module, INU) | |
| Continuous output current | 416 A | |
| Intermittent output current | 458 A | |
| Continuous current (high overload) | 312 A | |
| Rated current | 416 A | |
| Output frequency | 0-599Hz | |
| Short-circuit rating | 100kA | |
| Standard I/O | I/O and Relay Option OC7C1 | |
| Height | 1295 mm | |
| Width | 140 mm | |
| Depth | 566 mm | |
| Net weight | 73 kg | |
| Gross weight | 107 kg | |
| EAN | 5715253728070 | |
| ECCN (EU) | Y901 | |
| ECCN (US) | 3A999.a | |
Documents