Danfoss 137U6450 - VACON NXP Liquid Cooled (90 kW, IP00, 380-500V)
- Vacon NXP Frequency Converter
- 380 – 500 Vac (465-800 Vdc), 168 Amp,IP00
- Alpha-numeric display
- IEC61800-3 for IT networks
- No Brake
- A Slot: OPTA1 w.galv.isol 2AI&1AO
- B Slot: 2RO(NO/NC)
- C Slot: Line voltage meas.
- D Slot: 6 programmableDI/DO
- E Slot: 2-port ethernet
- Manual: English
- Frame 05 liquid cooled
Model code:
NXP01685-A0T0IWG-A8A2D7B1E9+MASG+ARFIFF03+GABV
NXP01685-A0T0IWG-A8A2D7B1E9+MASG+ARFIFF03+GABV
Product details
| Product Group | NXP | NXP Frequency Converter |
| Customized Drive | +BM26 | Vacon Dark Grey NXP |
| Mechanical Modification | W | Liquid cooling |
| Mains voltage | 5- | 380 – 500 Vac (465-800 Vdc) |
| Current | 0168 | 168 Amp |
| Control Keypad | A | Alpha-numeric display |
| Enclosure | 0 | IP00 |
| EMC emission levels | T | IEC61800-3 for IT networks |
| Brake Chopper | 0 | No Brake |
| Electrical Modification | I | INU, no charging circuit |
| Card Modifications | G- | FiberConnection+Varnished PCB |
| Shipping Package | +GSCB | Cardboard box as Shipping pack |
| Warranty | +WT01 | Warranty 12/18 months |
| Gland Plate Option | +QGNO | No conduit plate |
| Option Slot A | A8 | OPTA1 w.galv.isol 2AI&1AO |
| Option Slot B | A2 | 2RO(NO/NC) |
| Option Slot C | D7 | Line voltage meas. |
| Option Slot D | B1 | 6 programmableDI/DO |
| Option Slot E | E9 | 2-port ethernet |
| Firmware language package | +FL22 | UK,FR,IT,ES,PT;WestEur |
| Documentation Level | +DPAP | Paper manuals |
| Documentation Lang. Preference | +DLUK | English |
| System Firmware | +FNP02 | System software NXP |
| Software license | +MASG | Grid Converter license |
| Application | +ARFIFF03 | Grid Converter NXA,NXI,NXP |
| Parameter Set | NONE | none |
| Motor Parameter Default | +LS50 | Default Motor frequency 50HZ |
| Labeling options | +LPC1 | no additional labels |
| CE Approval | +GACE | CE Approval |
| UL Approval | +GAUL | UL approval |
| RCM Approval | +GACT | RCM Approval N16307 |
| Marine approval | +GABV | Bureau Veritas |
| KC Approval | +GAKC | Korean Approval |
| Ukrainian Approval | +GAUA | Ukrainian Approval |
| EAC Approval | +GAEA | EAC Approval |
| Frame Size | CH05 | Frame 05 liquid cooled |
| Motor Power Low Overload [kW] | 90 | |
| Motor Power High Overload [kW] | 75 | |
| Dimensions WxHxD [mm] | 246X553X264 | |
| Continuous Current (NO) [A] | 153 | |
| Continuous Current (HO) [A] | 112 |
Technical data
| Motor power | 90 kW | |
| Mains voltage | 380 – 500 Vac (465-800 Vdc) | |
| Phase | Three-phase | |
| Protection rating | IP00 | |
| Frame size | CH05 | |
| RFI filter | None (EMC C4) | |
| Brake chopper | No | |
| Control panel | Alphanumeric Keypad | |
| Product type | NXP Frequency Converter | |
| Continuous output current | 153 A | |
| Continuous current (high overload) | 112 A | |
| Rated current | 168 A | |
| Power, high overload | 75 kW | |
| Power, low overload | 90 kW | |
| Standard I/O | OPTA1 w.galv.isol 2AI&1AO | |
| Height | 553 mm | |
| Width | 246 mm | |
| Depth | 264 mm | |
| Net weight | 40 kg | |
| Gross weight | 41 kg | |
| EAN | 5715253749464 | |
| ECCN (EU) | Y901 | |
| ECCN (US) | 3A999.a | |
Documents
Operating guides, design guides, certificates and CAD drawings for 137U6450 are available on request. Ask for documents →
Other 90 kW variants in VACON® NXP Liquid Cooled
- 132H1970 IP00 · None · CH05
- 136L6829 IP00 · None · CH05
- 136L6830 IP00 · None · CH05
- 136Z6051 IP00 · None · CH05
- 136H4649 IP00 · None · CH05
- 136L6831 IP00 · None · CH05
- 137L2849 IP00 · None · CH05
- 132H3811 IP00 · None · CH05
- 132X7364 IP00 · None · CH05
- 137G2808 IP00 · None · CH05
- 137L4395 IP00 · None · CH05
- 137G3612 IP00 · None · CH05
- 137G5515 IP00 · None · CH05
- 136X8230 IP00 · None · CH05
- 132X3645 IP00 · None · CH05
- 132X1067 IP00 · None · CH05
- 132N4908 IP00 · None · CH05
- 132X1417 IP00 · None · CH05
- 137H0518 IP00 · None · CH05
- 137G1245 IP00 · None · CH05
- 132X9983 IP00 · None · CH05
- 137H0569 IP00 · None · CH05
- 136U4067 IP00 · None · CH05
- 137U0778 IP00 · None · CH05