Home/Climate Solutions for cooling/Valves/Expansion valves/Electric expansion valves/Electric expansion valves for HVAC-R/ETS Colibri®/ 034G7711
034G7711
Danfoss 034G7711 - Electric expansion valve, ETS 50C
- Refrigerant temperature [°C] [max]: 95
- Refrigerant temperature [°F] [max]: 203
- Inlet size [mm]: 22
- Outlet size [mm]: 28
- Inlet size [in]: 7/8 in
- Outlet size [in]: 1 1/8 in
Similar products
- Genuine Danfoss products
- Danfoss manufacturer warranty
- Reply within one business day
- Worldwide delivery
Product details
| Type | ETS 50C | |
| Product group | Expansion valves | |
| Product Name Description | Electric expansion valve | |
| Ambient temperature range [°C] [max] | 70 °C | |
| Ambient temperature range [°C] [min] | -40 °C | |
| Ambient temperature range [°F] [max] | 158 °F | |
| Ambient temperature range [°F] [min] | -40 °F | |
| Approval | ATEX; CCC; CE; CMIM; EAC; UKCA; UR; UA | |
| Balanced port [Yes/No] | Yes | |
| Body material | Stainless steel | |
| Brand | Colibri | |
| CE mark | Yes | |
| China RoHS compliance | Yes with exemptions | |
| China RoHS exemption clause | 7.3 | |
| Compatible Danfoss controllers | EKE 1A; EKE 1B; EKE 1C; MCX 061V; MCX 152V | |
| Connection Code | (3002:X:22; 3002:X:29) | |
| Connection material | Bi-metal: Steel/copper | |
| Contains batteries | No | |
| Direction | Straightway | |
| Electrical conn. Male/Female | Male | |
| Electrical connection | M12 | |
| Electrical connection size | 4 pin | |
| Enclosure rating IP | IP67 | |
| EU RoHS compliance | Yes with exemptions | |
| EU RoHS exemption clause | 6(c) | |
| EX Sales text | II 3G Ex ec IIB T4 Gc | |
| Flow direction | Bi-flow | |
| Flow direction indicator | Laser engraved 2-way arrow | |
| Fluid Group | 1 | |
| Full travel time speed [s] [max] | 6 s | |
| Full travel time speed [s] [min] | 3 s | |
| Identical product | 034G7701 | |
| Inlet connection type | Solder ODF | |
| Inlet size [in] | 7/8 in | |
| Inlet size [mm] | 22 | |
| Kv value [m³/h] | 2.4 m³/h | |
| Lubricants compatibility | MO; POE; AB; Oilfree applications; PAG; PAO; PVE | |
| Manual operation option | AST-G service driver | |
| Max allowed duty cycle [%] | 100 % | |
| Max tot PowerCons CurrDrive[W] | 7.2 W | |
| Max tot PowerCons VoltDrive[W] | 7.2 W | |
| Max. Working Pressure [bar] | 50 bar | |
| Max. Working Pressure [psig] | 725 psig | |
| MaxOPD [bar] | 40 bar | |
| MaxOPD [psi] | 580 psi | |
| MaxOPD reverse [bar] | 40 bar | |
| MaxOPD reverse [psi] | 580 psi | |
| Motor type | Bi-polar | |
| Oil free refrigerants | R1234ze(E); R134a; R513A; R515A; R515B; R516A | |
| Operating current max. [A] | 0.8 A | |
| Outlet connection type | Solder ODF | |
| Outlet size [in] | 1 1/8 in | |
| Outlet size [mm] | 28 | |
| Packing format | Industrial pack | |
| PED category | Art. 4, par. 3 | |
| Phase current (peak) [mA] | 800 mA | |
| Phase current (RMS) [mA] | 600 mA | |
| Phase inductance [µH] | 14000 μH | |
| Product accessories | Stepper valve accessories | |
| Quantity per packing format | 12 pc | |
| Rated cap. cond. note | Full stroke open, normal flow | |
| Rated cap. conditions [IMP] | tcond=90 °F; tevap=40 °F; tliq=82 °F | |
| Rated cap. conditions [SI] | tcond=32 °C; tevap=5 °C; tliq=28 °C | |
| Rated cap. R404A/R507A [kW] | 200 kW | |
| Rated cap. R404A/R507A [TR] | 93.3 TR | |
| Rated capacity R134a [kW] | 210 kW | |
| Rated capacity R134a [TR] | 60.5 TR | |
| Rated capacity R22 [kW] | 267.7 kW | |
| Rated capacity R22 [TR] | 76.1 TR | |
| Rated capacity R407C [kW] | 294 kW | |
| Rated capacity R407C [TR] | 84.5 TR | |
| Rated capacity R410A [kW] | 323 kW | |
| Rated capacity R410A [TR] | 93.3 TR | |
| REACH Candidate List substances | Lead (CAS no. 7439-92-1); Cobalt dichloride (CAS no. 7646-79-9) | |
| Refrigerant temperature [°C] [max] | 95 | |
| Refrigerant temperature [°C] [min] | -40 °C | |
| Refrigerant temperature [°F] [max] | 203 | |
| Refrigerant temperature [°F] [min] | -40 °F | |
| Refrigerants | R1233zd(E); R1234yf; R1234ze(E); R1270; R134a; R22; R227ea; R23; R245fa; R290; R32; R404A; R407A; R407B; R407C; R407F; R407H; R410A; R412A; R413A; R417A; R422A; R422B; R422D; R427A; R438A; R442A; R444B; R447A; R448A; R449A; R449B; R450A; R452A; R452B; R454A; R454B; R454C; R455A; R463A; R502; R507A; R512A; R513A; R513B; R515A; R515B; R516A; R600; R600a; R152a; R500 | |
| Resistance [kOhm] | 0 kOhm | |
| SCIP dossier product name | ETS 12C-100C with sight glass | |
| Serviceable | No | |
| Sightglass | Type SG (N indicator) | |
| Step mode | 2-phase full step; Half step; Microstep (recommended) | |
| Total steps | 600 (full steps) | |
| UL approved refrigerants | R134a; R227ea; R23; R404A; R407A; R407C; R407F; R410A; R417A; R422A; R422D; R427A; R438A; R448A; R449A; R450A; R452A; R507A; R513A |
Technical data
| Product type | Expansion valves | |
| Net weight | 0.317 kg | |
| Gross weight | 0.417 kg | |
| Packed volume | 1.9 L | |
| EAN | 5702428539272 | |
Documents
Operating guides, design guides, certificates and CAD drawings for 034G7711 are available on request. Ask for documents →