132L1069
Danfoss 132L1069 - VACON 100 INDUSTRIAL Enclosed Drive (400 kW / 450 HP, IP21, 525-690V)
- Frequency converter
- VACON 100 Industrial
- 525-690 Vac 416 AmpIP21/NEMA1
- Graphical Keypad MK01
- C3 Commercial&Industry Environ
- B Slot: F3,3 Relay board
- C Slot: No board
- D Slot: E5,PROFIBUS DP with Sub-D9
- E Slot: BJ,STO, ATEX therm
- Fieldbus: Std protocol,Modbus,N2,BacNet
- Manual: English
- Frame 10
- ATEX: II (2) GD
Model code:
VACON0100-3L-0416-7-ED+SDE5+SEBJ+GNUL
VACON0100-3L-0416-7-ED+SDE5+SEBJ+GNUL
Product details
| Segment | NONE | VACON 100 Industrial |
| Mains voltage | -7 | 525-690 Vac |
| Current rating | -0416 | 416 Amp |
| Installation options | -ED | ED Enclosed Drive |
| Enclosure | +IP21 | IP21/NEMA1 |
| Control panel | +HMGR | Graphical Keypad MK01 |
| EMC emission limit category | +EMC3 | C3 Commercial&Industry Environ |
| Common mode filter (for DM) | +P000 | No Option |
| DUT filter (for DM) | +P000 | No Option |
| Brake chopper | +DBNO | No dynamic braking device |
| Real time clock option | +SRNO | No Battery for real time clock |
| Configurable power range | NONE | None |
| Power connections | +P000 | No Power options (+P000) |
| Cable entry | +Q000 | No option |
| Additional Equipment B | +Q000 | No option for Qxxx_B (+Q000) |
| Additonal Equipment C | +Q000 | No additonal option for Qxxx_C |
| Shipping package | +GSWP | Wooden box as shipping pack |
| Marine construction | +E000 | no option |
| B-Slot Option Board | +SBF3 | F3,3 Relay board |
| C- Slot Option Board | +SC00 | No board |
| D-Slot Option Board | +SDE5 | E5,PROFIBUS DP with Sub-D9 |
| E-Slot Option Board | +SEBJ | BJ,STO, ATEX therm |
| Internal FB selection | +FBM1 | Std protocol,Modbus,N2,BacNet |
| Documentation level | +DPAP | Paper Manuals |
| Document language preference | +DLUK | English |
| Firmware Language Pack | +FL01 | UK, DE, FI, SE, IT, FR lang |
| Application | +A0000 | No Application |
| Parameter Set | +L0000 | No application parameter set |
| Motor parameter default freq | +LS50 | 50 Hz def motor freq settings |
| Unit for measure for display | +LSSI | Metric Units of Measure |
| Labeling options | +LPC1 | no additional labels |
| UL approval | +GNUL | No Ul Approval (+GNUL) |
| Marine approval | NONE | None |
| RCM Approval | +GACT | RCM Approval N16307 |
| KC approval | +GAKC | KC Approval |
| Ukrainian approval | +GAUA | Ukrainian Approval |
| EAC Approval | +GAEA | EAC Approval |
| Auxilary power supply | +C000 | no option |
| DC power supply for aux device | +C000 | no option |
| AC socket for aux devices | +C000 | no option |
| Input Devices | +CIFU | (+CIFU) AC fuses |
| Common mode filter (for ED) | +P000 | no option |
| DU/DT, Sine filter (for ED) | +P000 | no option |
| Terminal Options | +CTIO | I/O Terminals |
| Door Equipments | +C000 | no option |
| Cabinet heater | +C000 | no option |
| Cabinet light | +C000 | no option |
| Motor heater control | +C000 | no option |
| Emergency stop options | +C000 | no option |
| Insulation fault sensor | +C000 | no option |
| Cabling from top | +C000 | no option |
| Back channel cooling | +C000 | no option |
| Cabinet Plinth | +CHPL | Base plint 100 mm |
| Empty extension segment | NONE | None |
| Standardized cabinet solution | NONE | None |
| Engineered cabinet solution | NONE | None |
| Product Group | VACON | |
| Product Series | 0100 | Vacon 100 series |
| Phase | -3L | 3 Phase AC Input |
| Customized | +BM26 | Vacon 100 |
| Main Circuit | +M000 | NONE |
| Firmware | +F0072 | Vacon0100 Software package |
| Max output frequency | NONE | None |
| Terminal Box | +T000 | NONE |
| Bypass Control Operation Mode | NONE | none_ |
| Bypass Input Type | NONE | none_ |
| Bypass power connection type | NONE | none_ |
| CE approval | +GACE | CE Approval (+GACE) |
| ATEX Approval | NONE | None |
| County Specific Approval | NONE | None |
| Warrenty time | +WT01 | Warranty 12/18 months (+WT01) |
| Frame Size | MR10 | Frame 10 |
| Motor Power Low Overload [kW] | 400 | |
| Motor Power High Overload [kW] | 355 | |
| Dimensions WxHxD [mm] net | 606 X 2155 X 639 | |
| Dimensions WxHxD [mm] Gross | 775 X 2435 X 880 | |
| Continuous Current (NO) [A] | 416 | |
| Continuous Current (HO) [A] | 385 | |
| Motor Power HP Low Overload | 450 | |
| Motor Power HP High Overload | 300 | |
| ATEX Marking 1 | ATEX: II (2) GD | |
| STAT NO | 04395 | |
| Method | HORIZONTAL |
Technical data
| Motor power | 400 kW / 450 HP | |
| Mains voltage | 525-690 Vac | |
| Phase | Three-phase | |
| Protection rating | IP21/NEMA1 | |
| Frame size | MR10 | |
| RFI filter | Class A2 (EMC C3) | |
| Brake chopper | No | |
| Control panel | Graphical Keypad | |
| Mains option | Integrated Fuse | |
| Fieldbus | Std protocol,Modbus,N2,BacNet | |
| Product type | Enclosed drive | |
| Continuous output current | 416 A | |
| Continuous current (high overload) | 385 A | |
| Rated current | 416 A | |
| Power, high overload | 355 kW | |
| Power, low overload | 400 kW | |
| Height | 2155 mm | |
| Width | 606 mm | |
| Depth | 639 mm | |
| Net weight | 420 kg | |
| Gross weight | 421 kg | |
| EAN | 5714853403721 | |
| ECCN (EU) | Y901 | |
| ECCN (US) | 3A999.a | |
Documents
Operating guides, design guides, certificates and CAD drawings for 132L1069 are available on request. Ask for documents →
Other 400 kW / 450 HP variants in VACON® 100 INDUSTRIAL Enclosed Drive
- 137U4235 IP21 · None · MR10
- 132H1308 IP21 · None · MR10
- 136L4103 IP21 · None · MR10
- 137N3702 IP21 · Class A2 · MR10
- 137N3698 IP21 · Class A2 · MR10
- 137N3707 IP21 · Class A2 · MR10
- 137N3716 IP21 · Class A2 · MR10
- 137N3710 IP21 · Class A2 · MR10
- 132N0995 IP21 · Class A2 · MR10
- 137H8947 IP21 · Class A2 · MR10
- 137N3653 IP21 · None · MR10
- 137U7882 IP21 · None · MR10
- 132N2069 IP21 · None · MR10
- 132N7944 IP21 · None · MR10
- 132X8089 IP54 · Class A2 · MR10
- 137U8427 IP54 · Class A2 · MR10
- 137U7153 IP54 · Class A2 · MR10
- 132N5778 IP54 · None · MR10
- 136G5692 IP54 · Class A2 · MR10