137U6035
Danfoss 137U6035 - VACON NXP Liquid Cooled Common DC Bus (838 kW, IP00, 525-690V)
- Vacon Brake Chopper Unit
- 525 – 690 Vac (640-1100 Vdc), 502 Amp,IP00
- Graphical panel
- IEC61800-3 for IT networks
- No Brake
- A Slot: OPTA1 w.galv.isol 2AI&1AO
- B Slot: 2RO(NO/NC)
- C Slot: No board
- D Slot: No board
- E Slot: PROFIBUS DP
- Manual: English
- Frame 62 liquid cooled
Model code:
NXB05026-G0T08WG-A8A20000E3+GACS
NXB05026-G0T08WG-A8A20000E3+GACS
Similar products
- Genuine Danfoss products
- Danfoss manufacturer warranty
- Reply within one business day
- Worldwide delivery
Product details
| Product Group | NXB | Brake Chopper Unit |
| Customized Drive | +BM26 | Vacon Dark Grey NXP |
| Mechanical Modification | W | Liquid cooling |
| Mains voltage | 6- | 525 – 690 Vac (640-1100 Vdc) |
| Current | 0502 | 502 Amp |
| Control Keypad | G | Graphical panel |
| Enclosure | 0 | IP00 |
| EMC emission levels | T | IEC61800-3 for IT networks |
| Brake Chopper | 0 | No Brake |
| Electrical Modification | 8 | BCU Brake chopper unit |
| Card Modifications | G- | FiberConnection+Varnished PCB |
| Shipping Package | +GSCB | Cardboard box as Shipping pack |
| Warranty | +WT01 | Warranty 12/18 months |
| Gland Plate Option | +QGNO | No conduit plate |
| Option Slot A | A8 | OPTA1 w.galv.isol 2AI&1AO |
| Option Slot B | A2 | 2RO(NO/NC) |
| Option Slot C | 00 | No board |
| Option Slot D | 00 | No board |
| Option Slot E | E3 | PROFIBUS DP |
| Firmware language package | +FL22 | UK,FR,IT,ES,PT;WestEur |
| Documentation Level | +DPAP | Paper manuals |
| Documentation Lang. Preference | +DLUK | English |
| System Firmware | +FNP02 | System software NXP |
| Software license | NONE | no software license |
| Application | +ABFIFF01 | Brake Chopper Unit NXB |
| Parameter Set | NONE | none |
| Motor Parameter Default | +LS50 | Default Motor frequency 50HZ |
| Labeling options | +LPC1 | no additional labels |
| CE Approval | +GACE | CE Approval |
| UL Approval | +GAUL | UL approval |
| RCM Approval | +GACT | RCM Approval N16307 |
| Marine approval | +GACS | China Classification Society |
| KC Approval | +GAKC | Korean Approval |
| Ukrainian Approval | +GAUA | Ukrainian Approval |
| EAC Approval | +GAEA | EAC Approval |
| Frame Size | CH62 | Frame 62 liquid cooled |
| Motor Power Low Overload [kW] | 838 | |
| Motor Power High Overload [kW] | - | |
| Dimensions WxHxD [mm] | 246X658X374 | |
| Continuous Current (NO) [A] | 2X502 | |
| Continuous Current (HO) [A] | - |
Technical data
| Motor power | 838 kW | |
| Mains voltage | 525 – 690 Vac (640-1100 Vdc) | |
| Protection rating | IP00 | |
| Frame size | CH62 | |
| RFI filter | None (EMC C4) | |
| Brake chopper | No | |
| Control panel | Graphical Keypad | |
| Product type | Brake Chopper Unit | |
| Continuous output current | 2 A | |
| Rated current | 502 A | |
| Power, low overload | 838 kW | |
| Standard I/O | OPTA1 w.galv.isol 2AI&1AO | |
| Height | 658 mm | |
| Width | 246 mm | |
| Depth | 374 mm | |
| Net weight | 55 kg | |
| Gross weight | 56 kg | |
| EAN | 5715253744971 | |
| ECCN (EU) | Y901 | |
| ECCN (US) | 3A999.a | |
Documents
Operating guides, design guides, certificates and CAD drawings for 137U6035 are available on request. Ask for documents →
Other 838 kW variants in VACON® NXP Liquid Cooled Common DC Bus
- 137L5807 IP00 · None · CH62
- 137X0352 IP00 · None · CH62
- 137U1412 IP00 · None · CH62
- 137U0511 IP00 · None · CH62
- 137U1413 IP00 · None · CH62
- 137U0512 IP00 · None · CH62
- 137X2232 IP00 · None · CH62
- 137U9468 IP00 · None · CH62
- 137U7626 IP00 · None · CH62
- 132L0926 IP00 · None · CH62
- 137U8082 IP00 · None · CH62
- 132N8632 IP00 · None · CH62
- 132N2199 IP00 · None · CH62
- 137U0367 IP00 · None · CH62
- 137H1222 IP00 · None · CH62
- 132N2202 IP00 · None · CH62
- 132N6328 IP00 · None · CH62
- 132L2263 IP00 · None · CH62
- 132L7557 IP00 · None · CH62
- 132N8166 IP00 · None · CH62
- 132L7725 IP00 · None · CH62
- 137L9390 IP00 · None · CH62
- 137X1371 IP00 · None · CH62
- 137N4224 IP00 · None · CH62