137L0960
Danfoss 137L0960 - VLT AQUA Drive FC 202 (800 kW / 1200 HP, IP54, 525-690V)
- Convertidor de frecuencia
- VLT® AQUA Drive FC-202
- (N800) 800 KW / 1200 HP, Specific Ratings: 670kW@525-550V, 950HP@575V, 800kW@690V
- Three phase, 525 - 690 VAC *,IP54/Type 12+main shield
- Filtro RFI
- Parada segura
- Panel de control gráfico (LCP)
- Coated PCB, Mains Disconnect + Fuse
- Última versión de software estándar
- Frame: E2H
- PROFIBUS DP MCA 101, MCB-112 PTC Therm. Card
- No C1 option, MCB-107 24V DC backup
- ATEX: II (2) G [Ex eb Gb] [Ex db Gb] / II (2) D [Ex tb Db]
Código de modelo:
FC-202N800T7E5MH2TGC3XXSXXXXA0B2CXXXXD0
FC-202N800T7E5MH2TGC3XXSXXXXA0B2CXXXXD0
Productos similares
- Productos Danfoss originales
- Garantía del fabricante Danfoss
- Respuesta en un día laborable
Detalles del producto
| Grupo de producto | FC- | VLT® AQUA Drive FC- |
| Serie | 202 | |
| Potencia nominal | N800 | (N800) 800 KW / 1200 HP |
| Fases | T | Trifásico |
| Tensión de red | 7 | 525 - 690 VAC * |
| Envolvente | E5M | IP54/Type 12+main shield |
| Filtro RFI | H2 | Filtro RFI |
| Freno - Parada segura | T | Parada segura |
| Panel de control (LCP) | G | Panel de control gráfico (LCP) |
| Barnizado de PCB | C | PCB barnizado |
| Opción de red | 3 | Seccionador de red + fusible |
| Adaptación A | X | Entradas de cable estándar |
| Adaptación B | X | Sin adaptación |
| Versión de software | SXXX | Última versión de software estándar |
| Paquete de idiomas | X | Paquete de idiomas estándar |
| Opción A | A0 | PROFIBUS DP MCA 101 |
| Opción B | B2 | MCB-112 PTC Therm. Card |
| Opción C0 MCO | CX | Sin opción C0 |
| Opción C1 | X | Sin opción C1 |
| Software opción C | XX | Sin opción de software |
| Opción D | D0 | MCB-107 24V DC backup |
| Tamaño de bastidor | E2H | |
| Potencia 150 % (HO) [kW] | 710 | |
| Potencia 110 % (NO) [kW] | 800 | |
| Altura [mm] | 2000,0 | |
| Anchura sin opciones C [mm] | 700,0 | |
| Profundidad [mm] | 510,0 | |
| Profundidad con opción A/B [mm] | 510,0 | |
| kVA | 1016 | |
| Pérdidas NO [W] | 12723 | |
| Pérdidas NO [W] | 12321 | |
| Pérdidas HO [W] | 10319 | |
| Pérdidas HO [W] | 10060 | |
| Corriente continua (NO) [A] | 889 | |
| Corriente intermitente (NO) [A] | 978 | |
| Corriente continua (NO) [A] | 850 | |
| Corriente intermitente (NO) [A] | 935 | |
| Corriente continua (HO) [A] | 763 | |
| Corriente intermitente (HO) [A] | 1144 | |
| Corriente continua (HO) [A] | 730 | |
| Corriente intermitente (HO) [A] | 1095 | |
| ATEX Marking 1 | ATEX: II (2) G [Ex eb Gb] [Ex | |
| ATEX Marking 2 | db Gb] / II (2) D [Ex tb Db] | |
| Power Rating at 525-550V | 670kW | |
| Power Rating at 575V | 950HP | |
| Power Rating at 690V | 800kW |
Datos técnicos
| Potencia del motor | 800 kW / 1200 HP | |
| Tensión de red | 525 - 690 VAC * | |
| Fases | Trifásico | |
| Grado de protección | IP54/Type 12+main shield | |
| Tamaño de bastidor | E2H | |
| Filtro RFI | Class A2 (EMC C3) | |
| Chopper de frenado | No | |
| Safe Torque Off (STO) | Sí | |
| Panel de control | Graphical LCP | |
| Barnizado de PCB | PCB barnizado | |
| Opción de red | Seccionador de red + fusible | |
| Bus de campo | PROFIBUS DP MCA 101 | |
| Tipo de producto | Convertidor de frecuencia | |
| Corriente de salida continua | 889 A | |
| Corriente continua (tensión alta) | 850 A | |
| Corriente de salida intermitente | 978 A | |
| Corriente continua (sobrecarga alta) | 763 A | |
| Potencia aparente | 1016 kVA | |
| Pérdidas de potencia | 12723 W | |
| Potencia, sobrecarga normal | 800 kW | |
| Potencia, sobrecarga alta | 710 kW | |
| Altura | 2000 mm | |
| Anchura | 700 mm | |
| Profundidad | 510 mm | |
| Profundidad con opciones A/B | 510 mm | |
| Peso neto | 318 kg | |
| Peso bruto | 318.3 kg | |
| EAN | 5715253479866 | |
| ECCN (EU) | Y901 | |
| ECCN (US) | 3A999.a | |
Documentos
Operating guides, design guides, certificates and CAD drawings for 137L0960 are available on request. Solicitar documentos →