131B6382
Danfoss 131B6382 - VLT AutomationDrive FC 302 (30 kW / 40 HP, IP21, 380-500V)
- Frequency converter
- VLT® AutomationDrive FC-302
- (P30K) 30 KW / 40 HP,
- Three phase, 380 - 500 VAC,IP21 / Type 1
- RFI Filter
- No brake chopper
- No Loc. Cont. Panel
- Coated PCB, Loadsharing
- Latest release std. SW.
- Frame: C1
- No A Option, No B Option
- No C1 option, No D option
Model code:
FC-302P30KT5E21H2XXCDXXSXXXXAXBXCXXXXDX
FC-302P30KT5E21H2XXCDXXSXXXXAXBXCXXXXDX
Similar products
- Genuine Danfoss products
- Danfoss manufacturer warranty
- Reply within one business day
Product details
| Product Group | FC- | VLT® AutomationDrive FC- |
| Series | 302 | |
| Power Rating | P30K | (P30K) 30 KW / 40 HP |
| Phase | T | Three phase |
| Mains Voltage | 5 | 380 - 500 VAC |
| Enclosure | E21 | IP21 / Type 1 |
| RFI Filter | H2 | RFI Filter |
| Brake - Safe Stop | X | No brake chopper |
| LCP | X | No Loc. Cont. Panel |
| Coating PCB | C | Coated PCB |
| Mains Option | D | Loadsharing |
| Adaptation A | X | Standard Cable Entries |
| Adaptation B | X | No adaptation |
| Software Release | SXXX | Latest release std. SW. |
| Software Language Pack | X | Standard Language Pack |
| A Option | AX | No A Option |
| B Option | BX | No B Option |
| C0 Option MCO | CX | No C0 option |
| C1 Option | X | No C1 option |
| C Option Software | XX | No software option |
| D Option | DX | No D option |
| Frame Size | C1 | |
| Power 150% (HO) [KW] | 30 | |
| Power 110% (NO) [KW] | 37 | |
| Height [mm] | 685,0 | |
| Width w/ no C options [mm] | 308,0 | |
| Depth [mm] | 311,0 | |
| Depth with Option A/B [mm] | 311,0 | |
| kVA | 42.3 | |
| Power Loss NO [W] | 698 | |
| Power Loss HO [W] | 570 | |
| Continuous Current (NO) [A] | 73 | |
| Intermittent Current (NO) [A] | 80.3 | |
| Continuous Current (NO) [A] | 65 | |
| Intermittent Current (NO) [A] | 71.5 | |
| Continuous Current (HO) [A] | 61 | |
| Intermittent Current (HO) [A] | 91.5 | |
| Continuous Current (HO) [A] | 52 | |
| Intermittent Current (HO) [A] | 78 |
Technical data
| Motor power | 30 kW / 40 HP | |
| Mains voltage | 380 - 500 VAC | |
| Phase | Three-phase | |
| Protection rating | IP21 / Type 1 | |
| Frame size | C1 | |
| RFI filter | Class A2 (EMC C3) | |
| Brake chopper | No | |
| Safe Torque Off | Yes | |
| Control panel | None | |
| PCB coating | Coated PCB | |
| Mains option | Loadsharing | |
| Fieldbus | None | |
| Product type | Frequency converter | |
| Continuous output current | 73 A | |
| Continuous current (high line) | 65 A | |
| Intermittent output current | 80.3 A | |
| Continuous current (high overload) | 61 A | |
| Apparent power | 42.3 kVA | |
| Power loss | 698 W | |
| Power, normal overload | 37 kW | |
| Power, high overload | 30 kW | |
| Height | 685 mm | |
| Width | 308 mm | |
| Depth | 311 mm | |
| Depth with A/B options | 311 mm | |
| Net weight | 37.05 kg | |
| Gross weight | 38.55 kg | |
| Packed volume | 188.2 L | |
| EAN | 5710107196241 | |
| ECCN (EU) | Y901 | |
| ECCN (US) | 3A999.a | |
Documents
Operating guides, design guides, certificates and CAD drawings for 131B6382 are available on request. Ask for documents →
Other 30 kW / 40 HP variants in VLT AutomationDrive FC 302
- 136N1703 IP20 · Class A1/B · B4
- 131G2717 IP20 · Class A1/B · B4
- 131Z3794 IP20 · Class A1/B · B4
- 131F5455 IP20 · Class A1/B · B4
- 131L7491 IP20 · Class A1/B · B4
- 134N7491 IP20 · Class A1/B · B4
- 136F8008 IP20 · Class A1/B · B4
- 132X0037 IP20 · Class A1/B · B4
- 132L3470 IP20 · Class A1/B · B4
- 136G9204 IP20 · Class A1/B · B4
- 136Z3987 IP20 · Class A1/B · B4
- 134N3258 IP20 · Class A1/B · B4
- 136X4344 IP20 · Class A1/B · B4
- 132N9593 IP20 · Class A1/B · B4
- 134F3307 IP20 · Class A1/B · B4
- 131H8056 IP20 · Class A1/B · B4
- 131Z6803 IP20 · Class A1/B · B4
- 131X3826 IP20 · Class A1/B · B4
- 131H3620 IP20 · Class A1/B · B4
- 132H9109 IP20 · Class A1/B · B4
- 137U8455 IP20 · Class A1/B · B4
- 167G5847 IP20 · Class A1/B · B4
- 135X2177 IP20 · Class A1/B · B4
- 131L9099 IP20 · Class A1/B · B4