Danfoss VLT AutomationDrive FC 302 FC-302P7K5T2E20H2XGXXXXSXXXXA0BZCXXXXD0
131H8545

Danfoss 131H8545 - VLT AutomationDrive FC 302 (7.5 kW / 10 HP, IP20, 200-240V)

  • Frequency converter
  • VLT® AutomationDrive FC-302
  • (P7K5) 7.5 KW / 10 HP,
  • Three phase, 200 - 240 VAC,(E20) IP20 / Chassis
  • RFI Filter
  • No brake chopper
  • Graphical Loc. Cont. Panel
  • Not coated PCB, No Mains Option
  • Latest release std. SW.
  • Frame: B3
  • PROFIBUS DP MCA 101, Safety PLC Interface
  • No C1 option, MCB-107 24V DC backup
Model code:
FC-302P7K5T2E20H2XGXXXXSXXXXA0BZCXXXXD0
Similar products
  • Genuine Danfoss products
  • Danfoss manufacturer warranty
  • Reply within one business day

Product details

Product GroupFC-VLT® AutomationDrive FC-
Series302
Power RatingP7K5(P7K5) 7.5 KW / 10 HP
PhaseTThree phase
Mains Voltage2200 - 240 VAC
EnclosureE20(E20) IP20 / Chassis
RFI FilterH2RFI Filter
Brake - Safe StopXNo brake chopper
LCPGGraphical Loc. Cont. Panel
Coating PCBXNot coated PCB
Mains OptionXNo Mains Option
Adaptation AXStandard Cable Entries
Adaptation BXNo adaptation
Software ReleaseSXXXLatest release std. SW.
Software Language PackXStandard Language Pack
A OptionA0PROFIBUS DP MCA 101
B OptionBZSafety PLC Interface
C0 Option MCOCXNo C0 option
C1 OptionXNo C1 option
C Option SoftwareXXNo software option
D OptionD0MCB-107 24V DC backup
Frame SizeB3
Power 160% (HO) [KW]7.5
Power 110% (NO) [KW]11
Height [mm]399,0
Width w/ no C options [mm]165,0
Width w/ two C options [mm]225,0
Depth [mm]249,0
Depth with Option A/B [mm]262,0
kVA11.1
Power Loss NO [W]514
Power Loss HO [W]371
Continuous Current (NO) [A]46.2
Intermittent Current (NO) [A]50.8
Continuous Current (HO) [A]30.8
Intermittent Current (HO) [A]49.3

Technical data

Motor power7.5 kW / 10 HP
Mains voltage200 - 240 VAC
PhaseThree-phase
Protection ratingIP20 / Chassis
Frame sizeB3
RFI filterClass A2 (EMC C3)
Brake chopperNo
Safe Torque OffYes
Control panelGraphical LCP
PCB coatingUncoated
Mains optionNone
FieldbusPROFIBUS DP MCA 101
Product typeFrequency converter
Continuous output current46.2 A
Intermittent output current50.8 A
Continuous current (high overload)30.8 A
Apparent power11.1 kVA
Power loss514 W
Power, normal overload11 kW
Power, high overload7.5 kW
Height399 mm
Width165 mm
Width with C options225 mm
Depth249 mm
Depth with A/B options262 mm
Net weight10.64 kg
Gross weight11.66 kg
EAN5702427590335
ECCN (EU)Y901
ECCN (US)3A999.a

Documents

Operating guides, design guides, certificates and CAD drawings for 131H8545 are available on request. Ask for documents →

Other 7.5 kW / 10 HP variants in VLT AutomationDrive FC 302

Request a quote

Price and delivery time, usually within one business day.

Genuine Danfoss · Manufacturer warranty · Worldwide delivery

We only use your details to answer this request. See our privacy policy.