Danfoss VLT HVAC Drive FC 102 FC-102P15KT4P21H2XXX3XXSXXXXAXBKCXXXXDX
131N2992

Danfoss 131N2992 - VLT HVAC Drive FC 102 (15 kW / 20 HP, IP21, 380-480V)

  • Frequency Converter
  • VLT® HVAC Drive FC-102
  • (P15K) 15 KW / 20 HP,
  • Three phase, 380 - 480 VAC,IP21 / Type 1 Backplate
  • RFI Filter
  • No brake chopper
  • No Loc. Cont. Panel
  • Not coated PCB, Mains Disconnect + Fuse
  • Latest release std. SW.
  • Frame: B1
  • No A Option, MCB-101 General purp. I/O
  • No C1 option, No D option
Model code:
FC-102P15KT4P21H2XXX3XXSXXXXAXBKCXXXXDX
Similar products
  • Genuine Danfoss products
  • Danfoss manufacturer warranty
  • Reply within one business day

Product details

Product GroupFC-VLT® HVAC Drive FC-
Series102
Power RatingP15K(P15K) 15 KW / 20 HP
PhaseTThree phase
Mains Voltage4380 - 480 VAC
EnclosureP21IP21 / Type 1 Backplate
RFI FilterH2RFI Filter
Brake - Safe StopXNo brake chopper
LCPXNo Loc. Cont. Panel
Coating PCBXNot coated PCB
Mains Option3Mains Disconnect + Fuse
Adaptation AXStandard Cable Entries
Adaptation BXNo adaptation
Software ReleaseSXXXLatest release std. SW.
Software Language PackXStandard Language Pack
A OptionAXNo A Option
B OptionBKMCB-101 General purp. I/O
C0 Option MCOCXNo C0 option
C1 OptionXNo C1 option
C Option SoftwareXXNo software option
D OptionDXNo D option
Frame SizeB1
Power 110% (NO) [KW]15
Height [mm]494,0
Width w/ no C options [mm]243,0
Depth [mm]261,0
Depth with Option A/B [mm]261,0
kVA22.2
Power Loss NO [W]392
Continuous Current (NO) [A]32
Intermittent Current (NO) [A]35.2
Continuous Current (NO) [A]27
Intermittent Current (NO) [A]29.7

Technical data

Motor power15 kW / 20 HP
Mains voltage380 - 480 VAC
PhaseThree-phase
Protection ratingIP21 / Type 1 Backplate
Frame sizeB1
RFI filterClass A2 (EMC C3)
Brake chopperNo
Control panelNone
PCB coatingUncoated
Mains optionMains Disconnect + Fuse
FieldbusNone
Product typeFrequency converter
Continuous output current32 A
Continuous current (high line)27 A
Intermittent output current35.2 A
Apparent power22.2 kVA
Power loss392 W
Power, normal overload15 kW
Height494 mm
Width243 mm
Depth261 mm
Depth with A/B options261 mm
Net weight21.59 kg
Gross weight25.21 kg
EAN5702427839229
ECCN (EU)Y901
ECCN (US)3A999.a

Documents

Operating guides, design guides, certificates and CAD drawings for 131N2992 are available on request. Ask for documents →

Other 15 kW / 20 HP variants in VLT HVAC Drive FC 102

Request a quote

Price and delivery time, usually within one business day.

Genuine Danfoss · Manufacturer warranty

We only use your details to answer this request. See our privacy policy.