131N4883
Danfoss 131N4883 - VLT HVAC Drive FC 102 (800 kW / 1200 HP, IP21, 380-480V)
- Frequency Converter
- NB: F-frame platform available until December 31, 2025
- VLT® HVAC Drive FC-102
- (P800) 800 KW / 1200 HP,
- Three phase, 380 - 480 VAC,IP21 / Type 1
- RFI Filter
- No brake chopper
- Graphical Loc. Cont. Panel
- Coated PCB, Mains Disconnect + Fuse
- Latest release std. SW.
- Frame: F4
- No A Option, MCB-101 General purp. I/O
- No C1 option, No D option
Model code:
FC-102P800T4E21H2XGC3XXSXXXXAXBKCXXXXDX
FC-102P800T4E21H2XGC3XXSXXXXAXBKCXXXXDX
Similar products
- Genuine Danfoss products
- Danfoss manufacturer warranty
- Reply within one business day
Product details
| Product Group | FC- | VLT® HVAC Drive FC- |
| Series | 102 | |
| Power Rating | P800 | (P800) 800 KW / 1200 HP |
| Phase | T | Three phase |
| Mains Voltage | 4 | 380 - 480 VAC |
| Enclosure | E21 | IP21 / Type 1 |
| RFI Filter | H2 | RFI Filter |
| Brake - Safe Stop | X | No brake chopper |
| LCP | G | Graphical Loc. Cont. Panel |
| Coating PCB | C | Coated PCB |
| Mains Option | 3 | Mains Disconnect + Fuse |
| Adaptation A | X | Standard Cable Entries |
| Adaptation B | X | No adaptation |
| Software Release | SXXX | Latest release std. SW. |
| Software Language Pack | X | Standard Language Pack |
| A Option | AX | No A Option |
| B Option | BK | MCB-101 General purp. I/O |
| C0 Option MCO | CX | No C0 option |
| C1 Option | X | No C1 option |
| C Option Software | XX | No software option |
| D Option | DX | No D option |
| Frame Size | F4 | |
| Power 110% (NO) [KW] | 800 | |
| Height [mm] | 2204,0 | |
| Width w/ no C options [mm] | 2400,0 | |
| Depth [mm] | 606,0 | |
| Depth with Option A/B [mm] | 606,0 | |
| kVA | 1012 | |
| Power Loss NO [W] | 17293 | |
| Power Loss NO [W] | 16229 | |
| Continuous Current (NO) [A] | 1460 | |
| Intermittent Current (NO) [A] | 1606 | |
| Continuous Current (NO) [A] | 1380 | |
| Intermittent Current (NO) [A] | 1518 |
Technical data
| Motor power | 800 kW / 1200 HP | |
| Mains voltage | 380 - 480 VAC | |
| Phase | Three-phase | |
| Protection rating | IP21 / Type 1 | |
| Frame size | F4 | |
| RFI filter | Class A2 (EMC C3) | |
| Brake chopper | No | |
| Control panel | Graphical LCP | |
| PCB coating | Coated PCB | |
| Mains option | Mains Disconnect + Fuse | |
| Fieldbus | None | |
| Product type | Frequency converter | |
| Continuous output current | 1460 A | |
| Continuous current (high line) | 1380 A | |
| Intermittent output current | 1606 A | |
| Apparent power | 1012 kVA | |
| Power loss | 17293 W | |
| Power, normal overload | 800 kW | |
| Height | 2204 mm | |
| Width | 2400 mm | |
| Depth | 606 mm | |
| Depth with A/B options | 606 mm | |
| Net weight | 1260 kg | |
| Gross weight | 1260.3 kg | |
| EAN | 5702427858282 | |
| ECCN (EU) | Y901 | |
| ECCN (US) | 3A999.a | |
Documents
Operating guides, design guides, certificates and CAD drawings for 131N4883 are available on request. Ask for documents →
Other 800 kW / 1200 HP variants in VLT HVAC Drive FC 102
- 137G4345 IP00 · Class A2 · DA4
- 135U2833 IP00 · Class A2 · DA4
- 135U2834 IP00 · Class A1 · DA4
- 136H4962 IP00 · Class A2 · DB4
- 134H5553 IP21 · Class A2 · F13
- 131U9981 IP21 · Class A2
- 136F4688 IP21 · Class A2 · F12
- 131Z4349 IP21 · Class A2
- 131U9961 IP21 · Class A1 · F13
- 134L1959 IP21 · Class A1 · F13
- 134L8912 IP21 · Class A2 · F4
- 132H1334 IP21 · Class A2 · F4
- 134L8911 IP21 · Class A2 · F4
- 136G7196 IP21 · Class A2 · F4
- 134N3506 IP21 · Class A2 · F2
- 134G8734 IP21 · Class A2 · F4
- 134H6668 IP21 · Class A2 · F4
- 134H6667 IP21 · Class A2 · F4
- 137H2346 IP21 · Class A2 · F2
- 134H1913 IP21 · Class A2 · F4
- 134H1912 IP21 · Class A2 · F2
- 131G4544 IP21 · Class A2 · F4
- 131N5303 IP21 · Class A2 · F4
- 136L0309 IP21 · Class A2 · F2