131U0278
Danfoss 131U0278 - VLT AQUA Drive FC 202 (0.75 kW / 1 HP, IP55, 380-480V)
- Frequency converter
- VLT® AQUA Drive FC-202
- (PK75) 0.75 KW / 1.0 HP,
- Three phase, 380 - 480 VAC,IP55 / Type 12
- (H3) RFI Class A1/B (C1)
- No brake chopper
- Graphical Loc. Cont. Panel
- Not coated PCB, Mains Disconnect
- Latest release std. SW.
- Frame: A5
- No A Option, No B Option
- No C1 option, No D option
Model code:
FC-202PK75T4E55H3XGX1OXSXXXXAXBXCXXXXDX
FC-202PK75T4E55H3XGX1OXSXXXXAXBXCXXXXDX
Similar products
- Genuine Danfoss products
- Danfoss manufacturer warranty
- Reply within one business day
Product details
| Product Group | FC- | VLT® AQUA Drive FC- |
| Series | 202 | |
| Power Rating | PK75 | (PK75) 0.75 KW / 1.0 HP |
| Phase | T | Three phase |
| Mains Voltage | 4 | 380 - 480 VAC |
| Enclosure | E55 | IP55 / Type 12 |
| RFI Filter | H3 | (H3) RFI Class A1/B (C1) |
| Brake - Safe Stop | X | No brake chopper |
| LCP | G | Graphical Loc. Cont. Panel |
| Coating PCB | X | Not coated PCB |
| Mains Option | 1 | Mains Disconnect |
| Adaptation A | O | Metric thread cable entry |
| Adaptation B | X | No adaptation |
| Software Release | SXXX | Latest release std. SW. |
| Software Language Pack | X | Standard Language Pack |
| A Option | AX | No A Option |
| B Option | BX | No B Option |
| C0 Option MCO | CX | No C0 option |
| C1 Option | X | No C1 option |
| C Option Software | XX | No software option |
| D Option | DX | No D option |
| Frame Size | A5 | |
| Power 150% (HO) [KW] | 0.75 | |
| Power 110% (NO) [KW] | 0.75 | |
| Height [mm] | 420,0 | |
| Width w/ no C options [mm] | 242,0 | |
| Depth [mm] | 200,0 | |
| Depth with Option A/B [mm] | 200,0 | |
| kVA | 1.66 | |
| Power Loss NO [W] | 46 | |
| Power Loss HO [W] | 46 | |
| Continuous Current (NO) [A] | 2.4 | |
| Intermittent Current (NO) [A] | 2.64 | |
| Continuous Current (NO) [A] | 2.1 | |
| Intermittent Current (NO) [A] | 2.31 | |
| Continuous Current (HO) [A] | 2.4 | |
| Intermittent Current (HO) [A] | 3.6 | |
| Continuous Current (HO) [A] | 2.1 | |
| Intermittent Current (HO) [A] | 3.15 |
Technical data
| Motor power | 0.75 kW / 1 HP | |
| Mains voltage | 380 - 480 VAC | |
| Phase | Three-phase | |
| Protection rating | IP55 / Type 12 | |
| Frame size | A5 | |
| RFI filter | Class A1/B (EMC C1) | |
| Brake chopper | No | |
| Control panel | Graphical LCP | |
| PCB coating | Uncoated | |
| Mains option | Mains Disconnect | |
| Fieldbus | None | |
| Product type | Frequency converter | |
| Continuous output current | 2.4 A | |
| Continuous current (high line) | 2.1 A | |
| Intermittent output current | 2.64 A | |
| Continuous current (high overload) | 2.4 A | |
| Apparent power | 1.66 kVA | |
| Power loss | 46 W | |
| Power, normal overload | 0.75 kW | |
| Power, high overload | 0.75 kW | |
| Height | 420 mm | |
| Width | 242 mm | |
| Depth | 200 mm | |
| Depth with A/B options | 200 mm | |
| Net weight | 11.31 kg | |
| Gross weight | 11.93 kg | |
| Packed volume | 52.4 L | |
| EAN | 5702427913073 | |
| ECCN (EU) | Y901 | |
| ECCN (US) | 3A999.a | |
Documents
Operating guides, design guides, certificates and CAD drawings for 131U0278 are available on request. Ask for documents →
Other 0.75 kW / 1 HP variants in VLT AQUA Drive FC 202
- 137H3762 IP20 · Class A1/B · A2
- 136X4867 IP20 · Class A1/B · A2
- 132N8056 IP20 · Class A1/B · A2
- 167G7182 IP20 · Class A1/B · A2
- 132X0808 IP20 · Class A1/B · A2
- 137H9843 IP20 · Class A1/B · A2
- 131U1157 IP20 · Class A1/B · A2
- 137G1504 IP20 · Class A1/B · A2
- 134U8652 IP20 · Class A1/B · A2
- 134U4473 IP20 · Class A1/B · A2
- 132X0387 IP20 · Class A1/B · A2
- 134U9201 IP20 · Class A1/B · A2
- 132N9628 IP20 · Class A1/B · A2
- 137G5008 IP20 · Class A1/B · A2
- 167F9584 IP20 · Class A1/B · A2
- 132N8635 IP20 · Class A1/B · A2
- 134H5926 IP20 · Class A1/B · A2
- 132N4709 IP20 · Class A1/B · A2
- 131F9809 IP20 · Class A1/B · A2
- 167G2649 IP20 · Class A1/B · A2
- 137H3908 IP20 · Class A1/B · A2
- 135X6600 IP20 · Class A1/B · A2
- 137H1247 IP20 · Class A1/B · A2
- 131H2084 IP20 · Class A1/B · A2