131U0556
Danfoss 131U0556 - VLT HVAC Drive FC 102 (45 kW / 60 HP, IP55, 380-480V)
- Frequency Converter
- VLT® HVAC Drive FC-102
- (P45K) 45 KW / 60 HP,
- Three phase, 380 - 480 VAC,IP55 / Type 12
- (H1) RFI Class A1/B (C1)
- No brake chopper
- Graphical Loc. Cont. Panel
- Not coated PCB, No Mains Option
- Latest release std. SW.
- Frame: C1
- No A Option, MCB-101 General purp. I/O
- No C1 option, MCB-107 24V DC backup
Model code:
FC-102P45KT4E55H1XGXXXXSXXXXAXBKCXXXXD0
FC-102P45KT4E55H1XGXXXXSXXXXAXBKCXXXXD0
Similar products
- Genuine Danfoss products
- Danfoss manufacturer warranty
- Reply within one business day
Product details
| Product Group | FC- | VLT® HVAC Drive FC- |
| Series | 102 | |
| Power Rating | P45K | (P45K) 45 KW / 60 HP |
| Phase | T | Three phase |
| Mains Voltage | 4 | 380 - 480 VAC |
| Enclosure | E55 | IP55 / Type 12 |
| RFI Filter | H1 | (H1) RFI Class A1/B (C1) |
| Brake - Safe Stop | X | No brake chopper |
| LCP | G | Graphical Loc. Cont. Panel |
| Coating PCB | X | Not coated PCB |
| Mains Option | X | No Mains Option |
| Adaptation A | X | Standard Cable Entries |
| Adaptation B | X | No adaptation |
| Software Release | SXXX | Latest release std. SW. |
| Software Language Pack | X | Standard Language Pack |
| A Option | AX | No A Option |
| B Option | BK | MCB-101 General purp. I/O |
| C0 Option MCO | CX | No C0 option |
| C1 Option | X | No C1 option |
| C Option Software | XX | No software option |
| D Option | D0 | MCB-107 24V DC backup |
| Frame Size | C1 | |
| Power 110% (NO) [KW] | 45 | |
| Height [mm] | 685,0 | |
| Width w/ no C options [mm] | 308,0 | |
| Depth [mm] | 311,0 | |
| Depth with Option A/B [mm] | 311,0 | |
| kVA | 62.4 | |
| Power Loss NO [W] | 843 | |
| Continuous Current (NO) [A] | 90 | |
| Intermittent Current (NO) [A] | 99 | |
| Continuous Current (NO) [A] | 80 | |
| Intermittent Current (NO) [A] | 88 |
Technical data
| Motor power | 45 kW / 60 HP | |
| Mains voltage | 380 - 480 VAC | |
| Phase | Three-phase | |
| Protection rating | IP55 / Type 12 | |
| Frame size | C1 | |
| RFI filter | Class A1/B (EMC C1) | |
| Brake chopper | No | |
| Control panel | Graphical LCP | |
| PCB coating | Uncoated | |
| Mains option | None | |
| Fieldbus | None | |
| Product type | Frequency converter | |
| Continuous output current | 90 A | |
| Continuous current (high line) | 80 A | |
| Intermittent output current | 99 A | |
| Apparent power | 62.4 kVA | |
| Power loss | 843 W | |
| Power, normal overload | 45 kW | |
| Height | 685 mm | |
| Width | 308 mm | |
| Depth | 311 mm | |
| Depth with A/B options | 311 mm | |
| Net weight | 41.11 kg | |
| Gross weight | 44.11 kg | |
| Packed volume | 228.1 L | |
| EAN | 5702427915978 | |
| ECCN (EU) | Y901 | |
| ECCN (US) | 3A999.a | |
Documents
Operating guides, design guides, certificates and CAD drawings for 131U0556 are available on request. Ask for documents →
Other 45 kW / 60 HP variants in VLT HVAC Drive FC 102
- 167G4701 IP20 · Class A1/B · C3
- 131H5027 IP20 · Class A1/B · C3
- 131H6787 IP20 · Class A1/B · C3
- 131H2213 IP20 · Class A1/B · C3
- 131F0603 IP20 · Class A1/B · C3
- 131G0955 IP20 · Class A1/B · C3
- 134H4628 IP20 · Class A1/B · C3
- 136X5706 IP20 · Class A1/B · C3
- 131N9207 IP20 · Class A1/B · C3
- 131F0179 IP20 · Class A1/B · C3
- 167F2671 IP20 · Class A1/B · C3
- 131G0951 IP20 · Class A1/B · C3
- 131G0947 IP20 · Class A1/B · C3
- 131H3673 IP20 · Class A1/B · C3
- 131G3822 IP20 · Class A1/B · C3
- 134F6584 IP20 · Class A1/B · C3
- 131N7883 IP20 · Class A1/B · C3
- 136Z1297 IP20 · Class A1/B · C3
- 136X0472 IP20 · Class A1/B · C3
- 134L6402 IP20 · Class A1/B · C3
- 131L0371 IP20 · Class A1/B · C3
- 132X1522 IP20 · Class A1/B · C3
- 132N2436 IP20 · Class A1/B · C3
- 132L5775 IP20 · Class A1/B · C3