131U6867
Danfoss 131U6867 - VLT AutomationDrive FC 302 (45 kW / 60 HP, IP20, 525-600V)
- Frequency converter
- VLT® AutomationDrive FC-302
- (P45K) 45 KW / 60 HP,
- Three phase, 525 - 600 VAC,(E20) IP20 / Chassis
- No RFI Filter
- No brake chopper
- Graphical Loc. Cont. Panel
- Not coated PCB, No Mains Option
- Latest release std. SW.
- Frame: C3
- PROFIBUS DP MCA 101, No B Option
- MCB-113 Ext. Relay Card, MCB-107 24V DC backup
Model code:
FC-302P45KT6E20HXXGXXXXSXXXXA0BXCXRXXD0
FC-302P45KT6E20HXXGXXXXSXXXXA0BXCXRXXD0
Similar products
- Genuine Danfoss products
- Danfoss manufacturer warranty
- Reply within one business day
Product details
| Product Group | FC- | VLT® AutomationDrive FC- |
| Series | 302 | |
| Power Rating | P45K | (P45K) 45 KW / 60 HP |
| Phase | T | Three phase |
| Mains Voltage | 6 | 525 - 600 VAC |
| Enclosure | E20 | (E20) IP20 / Chassis |
| RFI Filter | HX | No RFI Filter |
| Brake - Safe Stop | X | No brake chopper |
| LCP | G | Graphical Loc. Cont. Panel |
| Coating PCB | X | Not coated PCB |
| Mains Option | X | No Mains Option |
| Adaptation A | X | Standard Cable Entries |
| Adaptation B | X | No adaptation |
| Software Release | SXXX | Latest release std. SW. |
| Software Language Pack | X | Standard Language Pack |
| A Option | A0 | PROFIBUS DP MCA 101 |
| B Option | BX | No B Option |
| C0 Option MCO | CX | No C0 option |
| C1 Option | R | MCB-113 Ext. Relay Card |
| C Option Software | XX | No software option |
| D Option | D0 | MCB-107 24V DC backup |
| Frame Size | C3 | |
| Power 150% (HO) [KW] | 45 | |
| Power 110% (NO) [KW] | 55 | |
| Height [mm] | 550,0 | |
| Width w/ no C options [mm] | 308,0 | |
| Depth [mm] | 333,0 | |
| Depth with Option A/B [mm] | 333,0 | |
| kVA | 61.7 | |
| Power Loss NO [W] | 1100 | |
| Power Loss HO [W] | 900 | |
| Continuous Current (NO) [A] | 87 | |
| Intermittent Current (NO) [A] | 95.7 | |
| Continuous Current (NO) [A] | 83 | |
| Intermittent Current (NO) [A] | 91.3 | |
| Continuous Current (HO) [A] | 65 | |
| Intermittent Current (HO) [A] | 97.5 | |
| Continuous Current (HO) [A] | 62 | |
| Intermittent Current (HO) [A] | 93 |
Technical data
| Motor power | 45 kW / 60 HP | |
| Mains voltage | 525 - 600 VAC | |
| Phase | Three-phase | |
| Protection rating | IP20 / Chassis | |
| Frame size | C3 | |
| RFI filter | None | |
| Brake chopper | No | |
| Safe Torque Off | Yes | |
| Control panel | Graphical LCP | |
| PCB coating | Uncoated | |
| Mains option | None | |
| Fieldbus | PROFIBUS DP MCA 101 | |
| Product type | Frequency converter | |
| Continuous output current | 87 A | |
| Continuous current (high line) | 83 A | |
| Intermittent output current | 95.7 A | |
| Continuous current (high overload) | 65 A | |
| Apparent power | 61.7 kVA | |
| Power loss | 1100 W | |
| Power, normal overload | 55 kW | |
| Power, high overload | 45 kW | |
| Height | 550 mm | |
| Width | 308 mm | |
| Depth | 333 mm | |
| Depth with A/B options | 333 mm | |
| Net weight | 34.47 kg | |
| Gross weight | 37.32 kg | |
| Packed volume | 178.3 L | |
| EAN | 5702427983274 | |
| ECCN (EU) | Y901 | |
| ECCN (US) | 3A999.a | |
Documents
Operating guides, design guides, certificates and CAD drawings for 131U6867 are available on request. Ask for documents →
Other 45 kW / 60 HP variants in VLT AutomationDrive FC 302
- 131U4883 IP20 · None · C3
- 131U2968 IP20 · None · C3
- 134G1357 IP20 · None · C3
- 131U8435 IP20 · None · C3
- 134F2407 IP20 · None · C3
- 167H1251 IP20 · None · C3
- 131N4636 IP20 · None · C3
- 131U1849 IP20 · None · C3
- 136G5728 IP20 · None · C3
- 136N8693 IP20 · None · C3
- 131F0213 IP20 · None · C3
- 131F0633 IP20 · None · C3
- 134X7199 IP20 · None · C3
- 131N3045 IP20 · None · C3
- 131N2914 IP20 · None · C3
- 136N7275 IP20 · None · C3
- 131U9716 IP20 · None · C3
- 134U8782 IP20 · None · C3
- 135X1252 IP20 · None · C3
- 131G5881 IP20 · None · C3
- 131G5880 IP20 · None · C3
- 137L6283 IP20 · None · C3
- 137L6203 IP20 · None · C3
- 131G3432 IP20 · None · C3