131U9050
Danfoss 131U9050 - VLT HVAC Drive FC 102 (710 kW / 1000 HP, IP21, 380-480V)
- Frequency Converter
- NB: F-frame platform available until December 31, 2025
- VLT® HVAC Drive FC-102
- (P710) 710 KW / 1000 HP,
- Three phase, 380 - 480 VAC,IP21 / Type 1
- RFI Filter
- Safe Stop
- Graphical Loc. Cont. Panel
- Coated PCB, Fuse
- Latest release std. SW.
- Frame: F1
- No A Option, MCB-101 General purp. I/O
- No C1 option, No D option
Model code:
FC-102P710T4E21H2TGC7XKSXXXXAXBKCXXXXDX
FC-102P710T4E21H2TGC7XKSXXXXAXBKCXXXXDX
Similar products
- Genuine Danfoss products
- Danfoss manufacturer warranty
- Reply within one business day
Product details
| Product Group | FC- | VLT® HVAC Drive FC- |
| Series | 102 | |
| Power Rating | P710 | (P710) 710 KW / 1000 HP |
| Phase | T | Three phase |
| Mains Voltage | 4 | 380 - 480 VAC |
| Enclosure | E21 | IP21 / Type 1 |
| RFI Filter | H2 | RFI Filter |
| Brake - Safe Stop | T | Safe Stop |
| LCP | G | Graphical Loc. Cont. Panel |
| Coating PCB | C | Coated PCB |
| Mains Option | 7 | Fuse |
| Adaptation A | X | Standard Cable Entries |
| Adaptation B | K | F Frame Common Motor Term |
| Software Release | SXXX | Latest release std. SW. |
| Software Language Pack | X | Standard Language Pack |
| A Option | AX | No A Option |
| B Option | BK | MCB-101 General purp. I/O |
| C0 Option MCO | CX | No C0 option |
| C1 Option | X | No C1 option |
| C Option Software | XX | No software option |
| D Option | DX | No D option |
| Frame Size | F1 | |
| Power 110% (NO) [KW] | 710 | |
| Height [mm] | 2204,0 | |
| Width w/ no C options [mm] | 1400,0 | |
| Depth [mm] | 606,0 | |
| Depth with Option A/B [mm] | 606,0 | |
| kVA | 873 | |
| Power Loss NO [W] | 14674 | |
| Power Loss NO [W] | 13213 | |
| Continuous Current (NO) [A] | 1260 | |
| Intermittent Current (NO) [A] | 1386 | |
| Continuous Current (NO) [A] | 1160 | |
| Intermittent Current (NO) [A] | 1276 |
Technical data
| Motor power | 710 kW / 1000 HP | |
| Mains voltage | 380 - 480 VAC | |
| Phase | Three-phase | |
| Protection rating | IP21 / Type 1 | |
| Frame size | F1 | |
| RFI filter | Class A2 (EMC C3) | |
| Brake chopper | No | |
| Safe Torque Off | Yes | |
| Control panel | Graphical LCP | |
| PCB coating | Coated PCB | |
| Mains option | Integrated Fuse | |
| Fieldbus | None | |
| Product type | Frequency converter | |
| Continuous output current | 1260 A | |
| Continuous current (high line) | 1160 A | |
| Intermittent output current | 1386 A | |
| Apparent power | 873 kVA | |
| Power loss | 14674 W | |
| Power, normal overload | 710 kW | |
| Height | 2204 mm | |
| Width | 1400 mm | |
| Depth | 606 mm | |
| Depth with A/B options | 606 mm | |
| Net weight | 1899 kg | |
| Gross weight | 1899.3 kg | |
| EAN | 5710107005970 | |
| ECCN (EU) | Y901 | |
| ECCN (US) | 3A999.a | |
Documents
Operating guides, design guides, certificates and CAD drawings for 131U9050 are available on request. Ask for documents →
Other 710 kW / 1000 HP variants in VLT HVAC Drive FC 102
- 135U2830 IP00 · Class A2 · DA4
- 136F9632 IP00 · Class A2 · DA4
- 135U2831 IP00 · Class A1 · DA4
- 134X7058 IP00 · Class A1 · DA4
- 131U9980 IP21 · Class A2
- 131Z1656 IP21 · Class A2
- 131U9960 IP21 · Class A1 · F11
- 134L1958 IP21 · Class A1 · F11
- 131G9510 IP21 · Class A2 · F1
- 131U7864 IP21 · Class A2 · F3
- 131U9052 IP21 · Class A2 · F1
- 131X8683 IP21 · Class A2 · F1
- 131U9028 IP21 · Class A2 · F1
- 131X6557 IP21 · Class A2 · F3
- 134N9710 IP21 · Class A2 · F3
- 131X2547 IP21 · Class A2 · F3
- 134G4528 IP21 · Class A2 · F3
- 134N2882 IP21 · Class A2 · F3
- 134U0583 IP21 · Class A2 · F1
- 134N5063 IP21 · Class A2 · F1
- 134G4527 IP21 · Class A2 · F1
- 137H7931 IP21 · Class A2 · F1
- 134X8293 IP21 · Class A2 · F1
- 131G7080 IP21 · Class A2 · F1