131X1369
Danfoss 131X1369 - VLT HVAC Drive FC 102 (1200 kW / 1600 HP, IP54, 525-690V)
- Frequency Converter
- NB: F-frame platform available until December 31, 2025
- VLT® HVAC Drive FC-102
- (P1M2) 1.2 MW / 1600 HP, Specific Ratings: 1000kW@525-550V, 1350HP@575V, 1200kW@690V
- Three phase, 525 - 690 VAC *,(E54) IP54 / Type 12
- RFI Filter
- Safe Stop
- Graphical Loc. Cont. Panel
- Coated PCB, Mains Disconnect + Fuse
- Latest release std. SW.
- Frame: F4
- No A Option, MCB-114 VLT Sensor Input
- No C1 option, MCB-107 24V DC backup
Model code:
FC-102P1M2T7E54H2TGC3XXSXXXXAXB4CXXXXD0
FC-102P1M2T7E54H2TGC3XXSXXXXAXB4CXXXXD0
Similar products
- Genuine Danfoss products
- Danfoss manufacturer warranty
- Reply within one business day
Product details
| Product Group | FC- | VLT® HVAC Drive FC- |
| Series | 102 | |
| Power Rating | P1M2 | (P1M2) 1.2 MW / 1600 HP |
| Phase | T | Three phase |
| Mains Voltage | 7 | 525 - 690 VAC * |
| Enclosure | E54 | (E54) IP54 / Type 12 |
| RFI Filter | H2 | RFI Filter |
| Brake - Safe Stop | T | Safe Stop |
| LCP | G | Graphical Loc. Cont. Panel |
| Coating PCB | C | Coated PCB |
| Mains Option | 3 | Mains Disconnect + Fuse |
| Adaptation A | X | Standard Cable Entries |
| Adaptation B | X | No adaptation |
| Software Release | SXXX | Latest release std. SW. |
| Software Language Pack | X | Standard Language Pack |
| A Option | AX | No A Option |
| B Option | B4 | MCB-114 VLT Sensor Input |
| C0 Option MCO | CX | No C0 option |
| C1 Option | X | No C1 option |
| C Option Software | XX | No software option |
| D Option | D0 | MCB-107 24V DC backup |
| Frame Size | F4 | |
| Power 110% (NO) [KW] | 1200 | |
| Height [mm] | 2204,0 | |
| Width w/ no C options [mm] | 2400,0 | |
| Depth [mm] | 606,0 | |
| Depth with Option A/B [mm] | 606,0 | |
| kVA | 1506 | |
| Power Loss NO [W] | 16190 | |
| Power Loss NO [W] | 16821 | |
| Continuous Current (NO) [A] | 1317 | |
| Intermittent Current (NO) [A] | 1449 | |
| Continuous Current (NO) [A] | 1260 | |
| Intermittent Current (NO) [A] | 1386 | |
| Power Rating at 525-550V | 1000kW | |
| Power Rating at 575V | 1350HP | |
| Power Rating at 690V | 1200kW |
Technical data
| Motor power | 1200 kW / 1600 HP | |
| Mains voltage | 525 - 690 VAC * | |
| Phase | Three-phase | |
| Protection rating | IP54 / Type 12 | |
| Frame size | F4 | |
| RFI filter | Class A2 (EMC C3) | |
| Brake chopper | No | |
| Safe Torque Off | Yes | |
| Control panel | Graphical LCP | |
| PCB coating | Coated PCB | |
| Mains option | Mains Disconnect + Fuse | |
| Fieldbus | None | |
| Product type | Frequency converter | |
| Continuous output current | 1317 A | |
| Continuous current (high line) | 1260 A | |
| Intermittent output current | 1449 A | |
| Apparent power | 1506 kVA | |
| Power loss | 16190 W | |
| Power, normal overload | 1200 kW | |
| Height | 2204 mm | |
| Width | 2400 mm | |
| Depth | 606 mm | |
| Depth with A/B options | 606 mm | |
| Net weight | 1037 kg | |
| Gross weight | 1037.3 kg | |
| EAN | 5710107031047 | |
| ECCN (EU) | Y901 | |
| ECCN (US) | 3A999.a | |
Documents
Operating guides, design guides, certificates and CAD drawings for 131X1369 are available on request. Ask for documents →
Other 1200 kW / 1600 HP variants in VLT HVAC Drive FC 102
- 134F6177 IP21 · Class A2 · F13
- 134H0226 IP21 · Class A2 · F13
- 134H2067 IP21 · Class A2
- 134N0025 IP21 · Class A2 · F13
- 131N6917 IP21 · Class A2 · F4
- 131N4864 IP21 · Class A2 · F2
- 131X0507 IP21 · Class A2 · F4
- 134H1916 IP21 · Class A2 · F4
- 136Z2694 IP21 · Class A2 · F4
- 131G6723 IP21 · Class A2 · F4
- 137G4352 IP21 · Class A2 · F2
- 131G6718 IP21 · Class A2 · F2
- 136Z2693 IP21 · Class A2 · F2
- 135U5594 IP21 · Class A2 · F4
- 131X3962 IP21 · Class A2 · F4
- 132L6913 IP21 · Class A2 · F4
- 131X1725 IP21 · Class A2 · F4
- 131U9492 IP21 · Class A2 · F4
- 131L9394 IP21 · Class A2 · F4
- 131X3961 IP21 · Class A2 · F2
- 131N1462 IP21 · Class A2 · F2
- 134N6503 IP21 · Class A2 · F2
- 131N0780 IP21 · Class A2 · F4
- 131X5990 IP21 · Class A2 · F4