Danfoss VLT HVAC Drive FC 102 FC-102N450T4E5MH2XLC3XQSXXXXAQBXCXXXXDX
132H5562

Danfoss 132H5562 - VLT HVAC Drive FC 102 (450 kW / 600 HP, IP54, 380-480V)

  • Frequency Converter
  • VLT® HVAC Drive FC-102
  • (N450) 450 KW / 600 HP,
  • Three phase, 380 - 480 VAC,IP54/Type 12+main shield
  • RFI Filter
  • No brake chopper
  • Graphical LCP + USB
  • Coated PCB, Mains Disconnect + Fuse
  • Latest release std. SW.
  • Frame: E1H
  • Modbus TCP MCA 122, No B Option
  • No C1 option, No D option
Model code:
FC-102N450T4E5MH2XLC3XQSXXXXAQBXCXXXXDX
Similar products
  • Genuine Danfoss products
  • Danfoss manufacturer warranty
  • Reply within one business day

Product details

Product GroupFC-VLT® HVAC Drive FC-
Series102
Power RatingN450(N450) 450 KW / 600 HP
PhaseTThree phase
Mains Voltage4380 - 480 VAC
EnclosureE5MIP54/Type 12+main shield
RFI FilterH2RFI Filter
Brake - Safe StopXNo brake chopper
LCPLGraphical LCP + USB
Coating PCBCCoated PCB
Mains Option3Mains Disconnect + Fuse
Adaptation AXStandard Cable Entries
Adaptation BQHeat-sink access
Software ReleaseSXXXLatest release std. SW.
Software Language PackXStandard Language Pack
A OptionAQModbus TCP MCA 122
B OptionBXNo B Option
C0 Option MCOCXNo C0 option
C1 OptionXNo C1 option
C Option SoftwareXXNo software option
D OptionDXNo D option
Frame SizeE1H
Power 110% (NO) [KW]450
Height [mm]2000,0
Width w/ no C options [mm]600,0
Depth [mm]510,0
Depth with Option A/B [mm]510,0
kVA554
Power Loss NO [W]8783
Power Loss NO [W]7969
Continuous Current (NO) [A]800
Intermittent Current (NO) [A]880
Continuous Current (NO) [A]730
Intermittent Current (NO) [A]803

Technical data

Motor power450 kW / 600 HP
Mains voltage380 - 480 VAC
PhaseThree-phase
Protection ratingIP54/Type 12+main shield
Frame sizeE1H
RFI filterClass A2 (EMC C3)
Brake chopperNo
Control panelGraphical LCP + USB
PCB coatingCoated PCB
Mains optionMains Disconnect + Fuse
FieldbusModbus TCP MCA 122
Product typeFrequency converter
Continuous output current800 A
Continuous current (high line)730 A
Intermittent output current880 A
Apparent power554 kVA
Power loss8783 W
Power, normal overload450 kW
Height2000 mm
Width600 mm
Depth510 mm
Depth with A/B options510 mm
Net weight258 kg
Gross weight298 kg
EAN5714853346059
ECCN (EU)Y901
ECCN (US)3A999.a

Documents

Operating guides, design guides, certificates and CAD drawings for 132H5562 are available on request. Ask for documents →

Other 450 kW / 600 HP variants in VLT HVAC Drive FC 102

Request a quote

Price and delivery time, usually within one business day.

Genuine Danfoss · Manufacturer warranty · Worldwide delivery