Danfoss VLT HVAC Drive FC 102 FC-102N450T4C54H4TGC7XXLX1XXA0BKCXXXXDX
132H6574

Danfoss 132H6574 - VLT HVAC Drive FC 102 (450 kW / 600 HP, IP54, 380-480V)

  • Frequency Converter
  • VLT® HVAC Drive FC-102
  • (N450) 450 KW / 600 HP,
  • Three phase, 380 - 480 VAC,SS BackChnl IP54/Tipo 12
  • RFI class A1 (C2)
  • Safe Stop
  • Graphical Loc. Cont. Panel
  • Coated PCB, Fuse
  • Condition Based Monitoring CBM
  • Frame: E1H
  • PROFIBUS DP MCA 101, MCB-101 General purp. I/O
  • No C1 option, No D option
Model code:
FC-102N450T4C54H4TGC7XXLX1XXA0BKCXXXXDX
Similar products
  • Genuine Danfoss products
  • Danfoss manufacturer warranty
  • Reply within one business day

Product details

Product GroupFC-VLT® HVAC Drive FC-
Series102
Power RatingN450(N450) 450 KW / 600 HP
PhaseTThree phase
Mains Voltage4380 - 480 VAC
EnclosureC54SS BackChnl IP54/Tipo 12
RFI FilterH4RFI class A1 (C2)
Brake - Safe StopTSafe Stop
LCPGGraphical Loc. Cont. Panel
Coating PCBCCoated PCB
Mains Option7Fuse
Adaptation AXStandard Cable Entries
Adaptation BXNo adaptation
Software ReleaseLX1XCondition Based Monitoring CBM
Software Language PackXStandard Language Pack
A OptionA0PROFIBUS DP MCA 101
B OptionBKMCB-101 General purp. I/O
C0 Option MCOCXNo C0 option
C1 OptionXNo C1 option
C Option SoftwareXXNo software option
D OptionDXNo D option
Frame SizeE1H
Power 110% (NO) [KW]450
Height [mm]2000,0
Width w/ no C options [mm]600,0
Depth [mm]510,0
Depth with Option A/B [mm]510,0
kVA554
Power Loss NO [W]8783
Power Loss NO [W]7969
Continuous Current (NO) [A]800
Intermittent Current (NO) [A]880
Continuous Current (NO) [A]730
Intermittent Current (NO) [A]803

Technical data

Motor power450 kW / 600 HP
Mains voltage380 - 480 VAC
PhaseThree-phase
Protection ratingSS BackChnl IP54/Tipo 12
Frame sizeE1H
RFI filterClass A1 (EMC C2)
Brake chopperNo
Safe Torque OffYes
Control panelGraphical LCP
PCB coatingCoated PCB
Mains optionIntegrated Fuse
FieldbusPROFIBUS DP MCA 101
Product typeFrequency converter
Continuous output current800 A
Continuous current (high line)730 A
Intermittent output current880 A
Apparent power554 kVA
Power loss8783 W
Power, normal overload450 kW
Height2000 mm
Width600 mm
Depth510 mm
Depth with A/B options510 mm
Net weight295 kg
Gross weight295.3 kg
EAN5714853356829
ECCN (EU)Y901
ECCN (US)3A999.a

Documents

Operating guides, design guides, certificates and CAD drawings for 132H6574 are available on request. Ask for documents →

Other 450 kW / 600 HP variants in VLT HVAC Drive FC 102

Request a quote

Price and delivery time, usually within one business day.

Genuine Danfoss · Manufacturer warranty