Danfoss VLT HVAC Drive FC 102 FC-102N200T4E5MH2TLC3XQLX1XXAQBXCXXXXDX
132H8364

Danfoss 132H8364 - VLT HVAC Drive FC 102 (200 kW / 300 HP, IP54, 380-480V)

  • Frequency Converter
  • VLT® HVAC Drive FC-102
  • (N200) 200 KW / 300 HP,
  • Three phase, 380 - 480 VAC,IP54/Type 12+main shield
  • RFI Filter
  • Safe Stop
  • Graphical LCP + USB
  • Coated PCB, Mains Disconnect + Fuse
  • Condition Based Monitoring CBM
  • Frame: D7H
  • Modbus TCP MCA 122, No B Option
  • No C1 option, No D option
Model code:
FC-102N200T4E5MH2TLC3XQLX1XXAQBXCXXXXDX
Similar products
  • Genuine Danfoss products
  • Danfoss manufacturer warranty
  • Reply within one business day

Product details

Product GroupFC-VLT® HVAC Drive FC-
Series102
Power RatingN200(N200) 200 KW / 300 HP
PhaseTThree phase
Mains Voltage4380 - 480 VAC
EnclosureE5MIP54/Type 12+main shield
RFI FilterH2RFI Filter
Brake - Safe StopTSafe Stop
LCPLGraphical LCP + USB
Coating PCBCCoated PCB
Mains Option3Mains Disconnect + Fuse
Adaptation AXStandard Cable Entries
Adaptation BQHeat-sink access
Software ReleaseLX1XCondition Based Monitoring CBM
Software Language PackXStandard Language Pack
A OptionAQModbus TCP MCA 122
B OptionBXNo B Option
C0 Option MCOCXNo C0 option
C1 OptionXNo C1 option
C Option SoftwareXXNo software option
D OptionDXNo D option
Frame SizeD7H
Power 110% (NO) [KW]200
Height [mm]1978,0
Width w/ no C options [mm]420,0
Depth [mm]386,0
Depth with Option A/B [mm]386,0
kVA274
Power Loss NO [W]4109
Power Loss NO [W]3561
Continuous Current (NO) [A]395
Intermittent Current (NO) [A]435
Continuous Current (NO) [A]361
Intermittent Current (NO) [A]397

Technical data

Motor power200 kW / 300 HP
Mains voltage380 - 480 VAC
PhaseThree-phase
Protection ratingIP54/Type 12+main shield
Frame sizeD7H
RFI filterClass A2 (EMC C3)
Brake chopperNo
Safe Torque OffYes
Control panelGraphical LCP + USB
PCB coatingCoated PCB
Mains optionMains Disconnect + Fuse
FieldbusModbus TCP MCA 122
Product typeFrequency converter
Continuous output current395 A
Continuous current (high line)361 A
Intermittent output current435 A
Apparent power274 kVA
Power loss4109 W
Power, normal overload200 kW
Height1978 mm
Width420 mm
Depth386 mm
Depth with A/B options386 mm
Net weight156 kg
Gross weight206 kg
EAN5714853375189
ECCN (EU)Y901
ECCN (US)3A999.a

Documents

Operating guides, design guides, certificates and CAD drawings for 132H8364 are available on request. Ask for documents →

Other 200 kW / 300 HP variants in VLT HVAC Drive FC 102

Request a quote

Price and delivery time, usually within one business day.

Genuine Danfoss · Manufacturer warranty · Worldwide delivery

We only use your details to answer this request. See our privacy policy.