Danfoss VLT HVAC Drive FC 102 FC-102N450T4E54H2TGR7XXSXXXXANB2CXXXXDX
132H8470

Danfoss 132H8470 - VLT HVAC Drive FC 102 (450 kW / 600 HP, IP54, 380-480V)

  • Frequency Converter
  • VLT® HVAC Drive FC-102
  • (N450) 450 KW / 600 HP,
  • Three phase, 380 - 480 VAC,(E54) IP54 / Type 12
  • RFI Filter
  • Safe Stop
  • Graphical Loc. Cont. Panel
  • Coated PCB 3C3 + Ruggedised, Fuse
  • Latest release std. SW.
  • Frame: E1H
  • EtherNet/IP MCA 121, MCB-112 PTC Therm. Card
  • No C1 option, No D option
  • ATEX: II (2) G [Ex eb Gb] [Ex db Gb] / II (2) D [Ex tb Db]
Model code:
FC-102N450T4E54H2TGR7XXSXXXXANB2CXXXXDX
Similar products
  • Genuine Danfoss products
  • Danfoss manufacturer warranty
  • Reply within one business day

Product details

Product GroupFC-VLT® HVAC Drive FC-
Series102
Power RatingN450(N450) 450 KW / 600 HP
PhaseTThree phase
Mains Voltage4380 - 480 VAC
EnclosureE54(E54) IP54 / Type 12
RFI FilterH2RFI Filter
Brake - Safe StopTSafe Stop
LCPGGraphical Loc. Cont. Panel
Coating PCBRCoated PCB 3C3 + Ruggedised
Mains Option7Fuse
Adaptation AXStandard Cable Entries
Adaptation BXNo adaptation
Software ReleaseSXXXLatest release std. SW.
Software Language PackXStandard Language Pack
A OptionANEtherNet/IP MCA 121
B OptionB2MCB-112 PTC Therm. Card
C0 Option MCOCXNo C0 option
C1 OptionXNo C1 option
C Option SoftwareXXNo software option
D OptionDXNo D option
Frame SizeE1H
Power 110% (NO) [KW]450
Height [mm]2000,0
Width w/ no C options [mm]600,0
Depth [mm]510,0
Depth with Option A/B [mm]510,0
kVA554
Power Loss NO [W]8783
Power Loss NO [W]7969
Continuous Current (NO) [A]800
Intermittent Current (NO) [A]880
Continuous Current (NO) [A]730
Intermittent Current (NO) [A]803
ATEX Marking 1ATEX: II (2) G [Ex eb Gb] [Ex
ATEX Marking 2db Gb] / II (2) D [Ex tb Db]

Technical data

Motor power450 kW / 600 HP
Mains voltage380 - 480 VAC
PhaseThree-phase
Protection ratingIP54 / Type 12
Frame sizeE1H
RFI filterClass A2 (EMC C3)
Brake chopperNo
Safe Torque OffYes
Control panelGraphical LCP
PCB coatingCoated PCB 3C3 + Ruggedised
Mains optionIntegrated Fuse
FieldbusEtherNet/IP MCA 121
Product typeFrequency converter
Continuous output current800 A
Continuous current (high line)730 A
Intermittent output current880 A
Apparent power554 kVA
Power loss8783 W
Power, normal overload450 kW
Height2000 mm
Width600 mm
Depth510 mm
Depth with A/B options510 mm
Net weight240 kg
Gross weight280 kg
EAN5714853376520
ECCN (EU)Y901
ECCN (US)3A999.a

Documents

Operating guides, design guides, certificates and CAD drawings for 132H8470 are available on request. Ask for documents →

Other 450 kW / 600 HP variants in VLT HVAC Drive FC 102

Request a quote

Price and delivery time, usually within one business day.

Genuine Danfoss · Manufacturer warranty · Worldwide delivery

We only use your details to answer this request. See our privacy policy.