Danfoss VLT Refrigeration Drive FC 103 FC-103N315T4E5MH2TLC3XQSXXXXAQBXCXXXXDX
132H8652

Danfoss 132H8652 - VLT Refrigeration Drive FC 103 (315 kW / 450 HP, IP54, 380-480V)

  • Frequency converter
  • VLT® Refrigeration Drive FC-103
  • (N315) 315 KW / 450 HP,
  • Three phase, 380 - 480 VAC,IP54/Type 12+main shield
  • RFI filter Class A2
  • Safe Stop
  • Graphical LCP + USB
  • Coated PCB, Mains Disconnect + Fuse
  • Latest release std. SW.
  • Modbus TCP MCA 122, No B Option
  • No C1 option, No D option
  • Frame: D7H
Model code:
FC-103N315T4E5MH2TLC3XQSXXXXAQBXCXXXXDX
Similar products
  • Genuine Danfoss products
  • Danfoss manufacturer warranty
  • Reply within one business day

Product details

Product GroupFC-VLT® Refrigeration Drive
Series103
Power RatingN315(N315) 315 KW / 450 HP
PhaseTThree phase
Mains Voltage4380 - 480 VAC
EnclosureE5MIP54/Type 12+main shield
RFI FilterH2RFI filter Class A2
Brake - Safe StopTSafe Stop
LCPLGraphical LCP + USB
Coating PCBCCoated PCB
Mains Option3Mains Disconnect + Fuse
Adaptation AXStandard Cable Entries
Adaptation BQHeat-sink access
Software ReleaseSXXXLatest release std. SW.
Software Language PackXStandard Language Pack
A OptionAQModbus TCP MCA 122
B OptionBXNo B Option
C0 Option MCOCXNo C0 option
C1 OptionXNo C1 option
C Option SoftwareXXNo software option
D OptionDXNo D option
Frame SizeD7H
Power 110% (NO) [KW]315
Height [mm]1978,0
Width w/ no C options [mm]420,0
Depth [mm]386,0
Depth with Option A/B [mm]386,0
kVA407
Power Loss NO [W]6663
Power Loss NO [W]5703
Continuous Current (NO) [A]588
Intermittent Current (NO) [A]647
Continuous Current (NO) [A]535
Intermittent Current (NO) [A]588

Technical data

Motor power315 kW / 450 HP
Mains voltage380 - 480 VAC
PhaseThree-phase
Protection ratingIP54/Type 12+main shield
Frame sizeD7H
RFI filterClass A2 (EMC C3)
Brake chopperNo
Safe Torque OffYes
Control panelGraphical LCP + USB
PCB coatingCoated PCB
Mains optionMains Disconnect + Fuse
FieldbusModbus TCP MCA 122
Product typeFrequency converter
Continuous output current588 A
Continuous current (high line)535 A
Intermittent output current647 A
Apparent power407 kVA
Power loss6663 W
Power, normal overload315 kW
Height1978 mm
Width420 mm
Depth386 mm
Depth with A/B options386 mm
Net weight185 kg
Gross weight235 kg
EAN5714853377978
ECCN (EU)Y901
ECCN (US)3A999.a

Documents

Operating guides, design guides, certificates and CAD drawings for 132H8652 are available on request. Ask for documents →

Other 315 kW / 450 HP variants in VLT Refrigeration Drive FC 103

Request a quote

Price and delivery time, usually within one business day.

Genuine Danfoss · Manufacturer warranty · Worldwide delivery

We only use your details to answer this request. See our privacy policy.