Danfoss VLT Refrigeration Drive FC 103 FC-103N450T4E20H2TGC7XXSXXXXAXBXCXXXXD0
132L0942

Danfoss 132L0942 - VLT Refrigeration Drive FC 103 (450 kW / 600 HP, IP20, 380-480V)

  • Frequency converter
  • VLT® Refrigeration Drive FC-103
  • (N450)450 KW / 600 HP,
  • Three phase, 380 - 480 VAC,(E20) IP20 / Chassis
  • RFI filter Class A2
  • Safe Stop
  • Graphical Loc. Cont. Panel
  • Coated PCB, Fuse
  • Latest release std. SW.
  • No A Option, No B Option
  • No C1 option, 24V DC backup
  • Frame: E3H
Model code:
FC-103N450T4E20H2TGC7XXSXXXXAXBXCXXXXD0
Similar products
  • Genuine Danfoss products
  • Danfoss manufacturer warranty
  • Reply within one business day

Product details

Product GroupFC-VLT® Refrigeration Drive
Series103
Power RatingN450(N450)450 KW / 600 HP
PhaseTThree phase
Mains Voltage4380 - 480 VAC
EnclosureE20(E20) IP20 / Chassis
RFI FilterH2RFI filter Class A2
Brake - Safe StopTSafe Stop
LCPGGraphical Loc. Cont. Panel
Coating PCBCCoated PCB
Mains Option7Fuse
Adaptation AXStandard Cable Entries
Adaptation BXNo adaptation
Software ReleaseSXXXLatest release std. SW.
Software Language PackXStandard Language Pack
A OptionAXNo A Option
B OptionBXNo B Option
C0 Option MCOCXNo C0 option
C1 OptionXNo C1 option
C Option SoftwareXXNo software option
D OptionD024V DC backup
Frame SizeE3H
Power 110% (NO) [KW]450
Height [mm]1578,0
Width w/ no C options [mm]507,0
Depth [mm]482,0
Depth with Option A/B [mm]482,0
kVA554
Power Loss NO [W]8783
Power Loss NO [W]7969
Continuous Current (NO) [A]800
Intermittent Current (NO) [A]880
Continuous Current (NO) [A]730
Intermittent Current (NO) [A]803

Technical data

Motor power450 kW / 600 HP
Mains voltage380 - 480 VAC
PhaseThree-phase
Protection ratingIP20 / Chassis
Frame sizeE3H
RFI filterClass A2 (EMC C3)
Brake chopperNo
Safe Torque OffYes
Control panelGraphical LCP
PCB coatingCoated PCB
Mains optionIntegrated Fuse
FieldbusNone
Product typeFrequency converter
Continuous output current800 A
Continuous current (high line)730 A
Intermittent output current880 A
Apparent power554 kVA
Power loss8783 W
Power, normal overload450 kW
Height1578 mm
Width507 mm
Depth482 mm
Depth with A/B options482 mm
Net weight272 kg
Gross weight272.3 kg
EAN5714853402182
ECCN (EU)Y901
ECCN (US)3A999.a

Documents

Operating guides, design guides, certificates and CAD drawings for 132L0942 are available on request. Ask for documents →

Other 450 kW / 600 HP variants in VLT Refrigeration Drive FC 103

Request a quote

Price and delivery time, usually within one business day.

Genuine Danfoss · Manufacturer warranty · Worldwide delivery

We only use your details to answer this request. See our privacy policy.