Danfoss VLT HVAC Drive FC 102 FC-102P45KT4P55H1TGXXXXSXXXXANB2CXXXXD0
132L6872

Danfoss 132L6872 - VLT HVAC Drive FC 102 (45 kW / 60 HP, IP55, 380-480V)

  • Frequency Converter
  • VLT® HVAC Drive FC-102
  • (P45K) 45 KW / 60 HP,
  • Three phase, 380 - 480 VAC,IP55 / Type12 Backplate
  • (H1) RFI Class A1/B (C1)
  • Safe Stop
  • Graphical Loc. Cont. Panel
  • Not coated PCB, No Mains Option
  • Latest release std. SW.
  • Frame: C1
  • EtherNet/IP MCA 121, MCB-112 PTC Therm. Card
  • No C1 option, MCB-107 24V DC backup
  • ATEX: II (2) G [Ex eb Gb] [Ex db Gb] / II (2) D [Ex tb Db]
Model code:
FC-102P45KT4P55H1TGXXXXSXXXXANB2CXXXXD0
Similar products
  • Genuine Danfoss products
  • Danfoss manufacturer warranty
  • Reply within one business day

Product details

Product GroupFC-VLT® HVAC Drive FC-
Series102
Power RatingP45K(P45K) 45 KW / 60 HP
PhaseTThree phase
Mains Voltage4380 - 480 VAC
EnclosureP55IP55 / Type12 Backplate
RFI FilterH1(H1) RFI Class A1/B (C1)
Brake - Safe StopTSafe Stop
LCPGGraphical Loc. Cont. Panel
Coating PCBXNot coated PCB
Mains OptionXNo Mains Option
Adaptation AXStandard Cable Entries
Adaptation BXNo adaptation
Software ReleaseSXXXLatest release std. SW.
Software Language PackXStandard Language Pack
A OptionANEtherNet/IP MCA 121
B OptionB2MCB-112 PTC Therm. Card
C0 Option MCOCXNo C0 option
C1 OptionXNo C1 option
C Option SoftwareXXNo software option
D OptionD0MCB-107 24V DC backup
Frame SizeC1
Power 110% (NO) [KW]45
Height [mm]685,0
Width w/ no C options [mm]308,0
Depth [mm]311,0
Depth with Option A/B [mm]311,0
kVA62.4
Power Loss NO [W]843
Continuous Current (NO) [A]90
Intermittent Current (NO) [A]99
Continuous Current (NO) [A]80
Intermittent Current (NO) [A]88
ATEX Marking 1ATEX: II (2) G [Ex eb Gb] [Ex
ATEX Marking 2db Gb] / II (2) D [Ex tb Db]

Technical data

Motor power45 kW / 60 HP
Mains voltage380 - 480 VAC
PhaseThree-phase
Protection ratingIP55 / Type12 Backplate
Frame sizeC1
RFI filterClass A1/B (EMC C1)
Brake chopperNo
Safe Torque OffYes
Control panelGraphical LCP
PCB coatingUncoated
Mains optionNone
FieldbusEtherNet/IP MCA 121
Product typeFrequency converter
Continuous output current90 A
Continuous current (high line)80 A
Intermittent output current99 A
Apparent power62.4 kVA
Power loss843 W
Power, normal overload45 kW
Height685 mm
Width308 mm
Depth311 mm
Depth with A/B options311 mm
Net weight42.84 kg
Gross weight45.84 kg
Packed volume228.1 L
EAN5714853884070
ECCN (EU)Y901
ECCN (US)3A999.a

Documents

Operating guides, design guides, certificates and CAD drawings for 132L6872 are available on request. Ask for documents →

Other 45 kW / 60 HP variants in VLT HVAC Drive FC 102

Request a quote

Price and delivery time, usually within one business day.

Genuine Danfoss · Manufacturer warranty · Worldwide delivery

We only use your details to answer this request. See our privacy policy.