132N7670
Danfoss 132N7670 - VLT AQUA Drive FC 202 (1000 kW / 1350 HP, IP54, 525-690V)
- Frequency converter
- VLT® AQUA Drive FC-202
- (P1M0) 1.0 MW / 1350 HP, Three phase
- 525 - 690 VAC *, (E54) IP54 / Type 12
- 12 Pulse + Class A2 RFI
- Safe Stop
- Graphical Loc. Cont. Panel
- Coated PCB, Mains Disconnect + Fuse
- Latest release std. SW.
- Frame: F13
- No C1 option, MCB-107 24V DC backup
- PROFIBUS DP MCA 101, MCB-101 General purp. I/O
Model code:
FC-202P1M0T7E54B2TGC3XKSXXXXA0BKCXXXXD0
FC-202P1M0T7E54B2TGC3XKSXXXXA0BKCXXXXD0
Similar products
- Genuine Danfoss products
- Danfoss manufacturer warranty
- Reply within one business day
Product details
| Product Group | FC- | VLT® AQUA Drive FC- |
| Series | 202 | |
| Power Rating | P1M0 | (P1M0) 1.0 MW / 1350 HP |
| Phase | T | Three phase |
| Mains Voltage | 7 | 525 - 690 VAC * |
| Enclosure | E54 | (E54) IP54 / Type 12 |
| RFI Filter | B2 | 12 Pulse + Class A2 RFI |
| Brake - Safe Stop | T | Safe Stop |
| LCP | G | Graphical Loc. Cont. Panel |
| Coating PCB | C | Coated PCB |
| Mains Option | 3 | Mains Disconnect + Fuse |
| Adaptation A | X | Standard Cable Entries |
| Adaptation B | K | F Frame Common Motor Term |
| Software Release | SXXX | Latest release std. SW. |
| Software Language Pack | X | Standard Language Pack |
| A Option | A0 | PROFIBUS DP MCA 101 |
| B Option | BK | MCB-101 General purp. I/O |
| C0 Option MCO | CX | No C0 option |
| C1 Option | X | No C1 option |
| C Option Software | XX | No software option |
| D Option | D0 | MCB-107 24V DC backup |
| Frame Size | F13 | |
| Power 150% (HO) [KW] | 900 | |
| Power 110% (NO) [KW] | 1000 | |
| Height [mm] | 2280,0 | |
| Width w/ no C options [mm] | 2802,0 | |
| Depth [mm] | 607,0 | |
| Depth with Option A/B [mm] | 607,0 | |
| kVA | 1267 | |
| Power Loss NO [W] | 13731 | |
| Power Loss NO [W] | 14250 | |
| Power Loss HO [W] | 12062 | |
| Power Loss HO [W] | 12524 | |
| Continuous Current (NO) [A] | 1108 | |
| Intermittent Current (NO) [A] | 1219 | |
| Continuous Current (NO) [A] | 1060 | |
| Intermittent Current (NO) [A] | 1166 | |
| Continuous Current (HO) [A] | 988 | |
| Intermittent Current (HO) [A] | 1482 | |
| Continuous Current (HO) [A] | 945 | |
| Intermittent Current (HO) [A] | 1418 |
Technical data
| Motor power | 1000 kW / 1350 HP | |
| Mains voltage | 525 - 690 VAC * | |
| Phase | Three-phase | |
| Protection rating | IP54 / Type 12 | |
| Frame size | F13 | |
| RFI filter | Class A2 (EMC C3) | |
| Brake chopper | No | |
| Safe Torque Off | Yes | |
| Control panel | Graphical LCP | |
| PCB coating | Coated PCB | |
| Mains option | Mains Disconnect + Fuse | |
| Fieldbus | PROFIBUS DP MCA 101 | |
| Product type | Frequency converter | |
| Continuous output current | 1108 A | |
| Continuous current (high line) | 1060 A | |
| Intermittent output current | 1219 A | |
| Continuous current (high overload) | 988 A | |
| Apparent power | 1267 kVA | |
| Power loss | 13731 W | |
| Power, normal overload | 1000 kW | |
| Power, high overload | 900 kW | |
| Height | 2280 mm | |
| Width | 2802 mm | |
| Depth | 607 mm | |
| Depth with A/B options | 607 mm | |
| Net weight | 1037 kg | |
| Gross weight | 1037.3 kg | |
| Packed volume | 0 L | |
| EAN | 5715253117713 | |
| ECCN (EU) | X.A.I.003 | |
| ECCN (US) | 3A999 | |
Documents
Operating guides, design guides, certificates and CAD drawings for 132N7670 are available on request. Ask for documents →
Other 1000 kW / 1350 HP variants in VLT AQUA Drive FC 202
- 135N8596 IP54 · Class A2 · F4