Danfoss VLT Refrigeration Drive FC 103 FC-103N132T4E5MH4XGC3XXSXXXXAXBKCXXXXDX
132X0694

Danfoss 132X0694 - VLT Refrigeration Drive FC 103 (132 kW / 200 HP, IP54, 380-480V)

  • Frequency converter
  • VLT® Refrigeration Drive FC-103
  • (N132) 132 KW / 200 HP,
  • Three phase, 380 - 480 VAC,IP54/Type 12+main shield
  • RFI filter Class A1
  • No brake chopper
  • Graphical Loc. Cont. Panel
  • Coated PCB, Mains Disconnect + Fuse
  • Latest release std. SW.
  • No A Option, MCB-101 General purpose I/O
  • No C1 option, No D option
  • Frame: D5H
Model code:
FC-103N132T4E5MH4XGC3XXSXXXXAXBKCXXXXDX
Similar products
  • Genuine Danfoss products
  • Danfoss manufacturer warranty
  • Reply within one business day

Product details

Product GroupFC-VLT® Refrigeration Drive
Series103
Power RatingN132(N132) 132 KW / 200 HP
PhaseTThree phase
Mains Voltage4380 - 480 VAC
EnclosureE5MIP54/Type 12+main shield
RFI FilterH4RFI filter Class A1
Brake - Safe StopXNo brake chopper
LCPGGraphical Loc. Cont. Panel
Coating PCBCCoated PCB
Mains Option3Mains Disconnect + Fuse
Adaptation AXStandard Cable Entries
Adaptation BXNo adaptation
Software ReleaseSXXXLatest release std. SW.
Software Language PackXStandard Language Pack
A OptionAXNo A Option
B OptionBKMCB-101 General purpose I/O
C0 Option MCOCXNo C0 option
C1 OptionXNo C1 option
C Option SoftwareXXNo software option
D OptionDXNo D option
Frame SizeD5H
Power 110% (NO) [KW]132
Height [mm]1324,0
Width w/ no C options [mm]325,0
Depth [mm]381,0
Depth with Option A/B [mm]381,0
kVA180
Power Loss NO [W]2949
Power Loss NO [W]2719
Continuous Current (NO) [A]260
Intermittent Current (NO) [A]286
Continuous Current (NO) [A]240
Intermittent Current (NO) [A]264

Technical data

Motor power132 kW / 200 HP
Mains voltage380 - 480 VAC
PhaseThree-phase
Protection ratingIP54/Type 12+main shield
Frame sizeD5H
RFI filterClass A1 (EMC C2)
Brake chopperNo
Control panelGraphical LCP
PCB coatingCoated PCB
Mains optionMains Disconnect + Fuse
FieldbusNone
Product typeFrequency converter
Continuous output current260 A
Continuous current (high line)240 A
Intermittent output current286 A
Apparent power180 kVA
Power loss2949 W
Power, normal overload132 kW
Height1324 mm
Width325 mm
Depth381 mm
Depth with A/B options381 mm
Net weight166 kg
Gross weight166.3 kg
EAN5715253154244
ECCN (EU)Y901
ECCN (US)3A999.a

Documents

Operating guides, design guides, certificates and CAD drawings for 132X0694 are available on request. Ask for documents →

Other 132 kW / 200 HP variants in VLT Refrigeration Drive FC 103

Request a quote

Price and delivery time, usually within one business day.

Genuine Danfoss · Manufacturer warranty · Worldwide delivery

We only use your details to answer this request. See our privacy policy.