Danfoss VLT HVAC Drive FC 102 FC-102N160T4E54H4XGR3XXSXXXXAKBXCXXXXD1
132X0787

Danfoss 132X0787 - VLT HVAC Drive FC 102 (160 kW / 250 HP, IP54, 380-480V)

  • Frequency Converter
  • VLT® HVAC Drive FC-102
  • (N160) 160 KW / 250 HP,
  • Three phase, 380 - 480 VAC,(E54) IP54 / Type 12
  • RFI class A1 (C2)
  • No brake chopper
  • Graphical Loc. Cont. Panel
  • Coated PCB 3C3 + Ruggedised, Mains Disconnect + Fuse
  • Latest release std. SW.
  • Frame: D5H
  • MCA 125 BACnet/IP, No B Option
  • No C1 option, MCB-117 Real time clock option
Model code:
FC-102N160T4E54H4XGR3XXSXXXXAKBXCXXXXD1
Similar products
  • Genuine Danfoss products
  • Danfoss manufacturer warranty
  • Reply within one business day

Product details

Product GroupFC-VLT® HVAC Drive FC-
Series102
Power RatingN160(N160) 160 KW / 250 HP
PhaseTThree phase
Mains Voltage4380 - 480 VAC
EnclosureE54(E54) IP54 / Type 12
RFI FilterH4RFI class A1 (C2)
Brake - Safe StopXNo brake chopper
LCPGGraphical Loc. Cont. Panel
Coating PCBRCoated PCB 3C3 + Ruggedised
Mains Option3Mains Disconnect + Fuse
Adaptation AXStandard Cable Entries
Adaptation BXNo adaptation
Software ReleaseSXXXLatest release std. SW.
Software Language PackXStandard Language Pack
A OptionAKMCA 125 BACnet/IP
B OptionBXNo B Option
C0 Option MCOCXNo C0 option
C1 OptionXNo C1 option
C Option SoftwareXXNo software option
D OptionD1MCB-117 Real time clock option
Frame SizeD5H
Power 110% (NO) [KW]160
Height [mm]1324,0
Width w/ no C options [mm]325,0
Depth [mm]381,0
Depth with Option A/B [mm]381,0
kVA218
Power Loss NO [W]3764
Power Loss NO [W]3628
Continuous Current (NO) [A]315
Intermittent Current (NO) [A]346
Continuous Current (NO) [A]302
Intermittent Current (NO) [A]332
Allowed PlantsD902 F605(D902) Kimpo Distribution (F605) Loves Park SAles

Technical data

Motor power160 kW / 250 HP
Mains voltage380 - 480 VAC
PhaseThree-phase
Protection ratingIP54 / Type 12
Frame sizeD5H
RFI filterClass A1 (EMC C2)
Brake chopperNo
Control panelGraphical LCP
PCB coatingCoated PCB 3C3 + Ruggedised
Mains optionMains Disconnect + Fuse
FieldbusMCA 125 BACnet/IP
Product typeFrequency converter
Continuous output current315 A
Continuous current (high line)302 A
Intermittent output current346 A
Apparent power218 kVA
Power loss3764 W
Power, normal overload160 kW
Height1324 mm
Width325 mm
Depth381 mm
Depth with A/B options381 mm
Net weight166 kg
Gross weight166.3 kg
EAN5715253155173
ECCN (EU)Y901
ECCN (US)3A999.a

Documents

Operating guides, design guides, certificates and CAD drawings for 132X0787 are available on request. Ask for documents →

Other 160 kW / 250 HP variants in VLT HVAC Drive FC 102

Request a quote

Price and delivery time, usually within one business day.

Genuine Danfoss · Manufacturer warranty · Worldwide delivery

We only use your details to answer this request. See our privacy policy.