132X5097
Danfoss 132X5097 - VLT HVAC Drive FC 102 (450 kW / 600 HP, IP54, 380-480V)
- Frequency Converter
- VLT® HVAC Drive FC-102
- (N450) 450 KW / 600 HP,
- Three phase, 380 - 480 VAC,IP54/Type 12+main shield
- RFI Filter
- Safe Stop
- Graphical LCP + USB
- Coated PCB, Mains Disconnect + Fuse
- Latest release std. SW.
- Frame: E1H
- No A Option, MCB-114 VLT Sensor Input
- No C1 option, No D option
Model code:
FC-102N450T4E5MH2TLC3XQSXXXXAXB4CXXXXDX
FC-102N450T4E5MH2TLC3XQSXXXXAXB4CXXXXDX
Similar products
- Genuine Danfoss products
- Danfoss manufacturer warranty
- Reply within one business day
Product details
| Product Group | FC- | VLT® HVAC Drive FC- |
| Series | 102 | |
| Power Rating | N450 | (N450) 450 KW / 600 HP |
| Phase | T | Three phase |
| Mains Voltage | 4 | 380 - 480 VAC |
| Enclosure | E5M | IP54/Type 12+main shield |
| RFI Filter | H2 | RFI Filter |
| Brake - Safe Stop | T | Safe Stop |
| LCP | L | Graphical LCP + USB |
| Coating PCB | C | Coated PCB |
| Mains Option | 3 | Mains Disconnect + Fuse |
| Adaptation A | X | Standard Cable Entries |
| Adaptation B | Q | Heat-sink access |
| Software Release | SXXX | Latest release std. SW. |
| Software Language Pack | X | Standard Language Pack |
| A Option | AX | No A Option |
| B Option | B4 | MCB-114 VLT Sensor Input |
| C0 Option MCO | CX | No C0 option |
| C1 Option | X | No C1 option |
| C Option Software | XX | No software option |
| D Option | DX | No D option |
| Frame Size | E1H | |
| Power 110% (NO) [KW] | 450 | |
| Height [mm] | 2000,0 | |
| Width w/ no C options [mm] | 600,0 | |
| Depth [mm] | 510,0 | |
| Depth with Option A/B [mm] | 510,0 | |
| kVA | 554 | |
| Power Loss NO [W] | 8783 | |
| Power Loss NO [W] | 7969 | |
| Continuous Current (NO) [A] | 800 | |
| Intermittent Current (NO) [A] | 880 | |
| Continuous Current (NO) [A] | 730 | |
| Intermittent Current (NO) [A] | 803 |
Technical data
| Motor power | 450 kW / 600 HP | |
| Mains voltage | 380 - 480 VAC | |
| Phase | Three-phase | |
| Protection rating | IP54/Type 12+main shield | |
| Frame size | E1H | |
| RFI filter | Class A2 (EMC C3) | |
| Brake chopper | No | |
| Safe Torque Off | Yes | |
| Control panel | Graphical LCP + USB | |
| PCB coating | Coated PCB | |
| Mains option | Mains Disconnect + Fuse | |
| Fieldbus | None | |
| Product type | Frequency converter | |
| Continuous output current | 800 A | |
| Continuous current (high line) | 730 A | |
| Intermittent output current | 880 A | |
| Apparent power | 554 kVA | |
| Power loss | 8783 W | |
| Power, normal overload | 450 kW | |
| Height | 2000 mm | |
| Width | 600 mm | |
| Depth | 510 mm | |
| Depth with A/B options | 510 mm | |
| Net weight | 295 kg | |
| Gross weight | 295.3 kg | |
| EAN | 5715253200767 | |
| ECCN (EU) | Y901 | |
| ECCN (US) | 3A999.a | |
Documents
Operating guides, design guides, certificates and CAD drawings for 132X5097 are available on request. Ask for documents →
Other 450 kW / 600 HP variants in VLT HVAC Drive FC 102
- 136G1004 IP00 · Class A2 · E3H
- 167F2828 IP00 · Class A2 · E3H
- 167F0908 IP00 · Class A2 · E3H
- 136U7950 IP00 · Class A2 · E3H
- 135U5325 IP00 · Class A2 · E3H
- 135U5248 IP00 · Class A2 · E3H
- 136F7198 IP00 · Class A1 · E3H
- 135X2769 IP00 · Class A1 · E3H
- 136G1029 IP00 · Class A1 · E3H
- 135N1733 IP00 · Class A2 · DB2
- 135N1732 IP00 · Class A2 · DB2
- 136U9510 IP20 · Class A2 · E3H
- 136U9506 IP20 · Class A2 · E3H
- 136U9502 IP20 · Class A2 · E3H
- 136U9499 IP20 · Class A2 · E3H
- 135U2899 IP20 · Class A2 · E3H
- 132L6398 IP20 · Class A2 · E3H
- 137X5063 IP20 · Class A2 · E3H
- 136F8226 IP20 · Class A2 · E3H
- 136F8156 IP20 · Class A2 · E3H
- 137X6557 IP20 · Class A2 · E3H
- 136Z1428 IP20 · Class A2 · E3H
- 167F8839 IP20 · Class A2 · E3H
- 137L4502 IP20 · Class A2 · E3H