Danfoss VLT HVAC Drive FC 102 FC-102P45KT4P66H3XGX1XXSXXXXAKBXCXXXXD0
132X6003

Danfoss 132X6003 - VLT HVAC Drive FC 102 (45 kW / 60 HP, IP66, 380-480V)

  • Frequency Converter
  • VLT® HVAC Drive FC-102
  • (P45K) 45 KW / 60 HP,
  • Three phase, 380 - 480 VAC,(P66) IP66 / NEMA 4X Backplate
  • (H3) RFI Class A1/B (C1)
  • No brake chopper
  • Graphical Loc. Cont. Panel
  • Not coated PCB, Mains Disconnect
  • Latest release std. SW.
  • Frame: C1
  • MCA 125 BACnet/IP, No B Option
  • No C1 option, MCB-107 24V DC backup
Model code:
FC-102P45KT4P66H3XGX1XXSXXXXAKBXCXXXXD0
Similar products
  • Genuine Danfoss products
  • Danfoss manufacturer warranty
  • Reply within one business day

Product details

Product GroupFC-VLT® HVAC Drive FC-
Series102
Power RatingP45K(P45K) 45 KW / 60 HP
PhaseTThree phase
Mains Voltage4380 - 480 VAC
EnclosureP66(P66) IP66 / NEMA 4X Backplate
RFI FilterH3(H3) RFI Class A1/B (C1)
Brake - Safe StopXNo brake chopper
LCPGGraphical Loc. Cont. Panel
Coating PCBXNot coated PCB
Mains Option1Mains Disconnect
Adaptation AXStandard Cable Entries
Adaptation BXNo adaptation
Software ReleaseSXXXLatest release std. SW.
Software Language PackXStandard Language Pack
A OptionAKMCA 125 BACnet/IP
B OptionBXNo B Option
C0 Option MCOCXNo C0 option
C1 OptionXNo C1 option
C Option SoftwareXXNo software option
D OptionD0MCB-107 24V DC backup
Frame SizeC1
Power 110% (NO) [KW]45
Height [mm]685,0
Width w/ no C options [mm]308,0
Depth [mm]311,0
Depth with Option A/B [mm]311,0
kVA62.4
Power Loss NO [W]843
Continuous Current (NO) [A]90
Intermittent Current (NO) [A]99
Continuous Current (NO) [A]80
Intermittent Current (NO) [A]88

Technical data

Motor power45 kW / 60 HP
Mains voltage380 - 480 VAC
PhaseThree-phase
Protection ratingIP66 / NEMA 4X Backplate
Frame sizeC1
RFI filterClass A1/B (EMC C1)
Brake chopperNo
Control panelGraphical LCP
PCB coatingUncoated
Mains optionMains Disconnect
FieldbusMCA 125 BACnet/IP
Product typeFrequency converter
Continuous output current90 A
Continuous current (high line)80 A
Intermittent output current99 A
Apparent power62.4 kVA
Power loss843 W
Power, normal overload45 kW
Height685 mm
Width308 mm
Depth311 mm
Depth with A/B options311 mm
Net weight43.52 kg
Gross weight46.52 kg
Packed volume228.1 L
EAN5715253210094
ECCN (EU)Y901
ECCN (US)3A999.a

Documents

Operating guides, design guides, certificates and CAD drawings for 132X6003 are available on request. Ask for documents →

Other 45 kW / 60 HP variants in VLT HVAC Drive FC 102

Request a quote

Price and delivery time, usually within one business day.

Genuine Danfoss · Manufacturer warranty

We only use your details to answer this request. See our privacy policy.