Danfoss VLT Refrigeration Drive FC 103 FC-103P90KT4P55H1TGC1XXLX1XXAQB5CXRXXD0
132X9219

Danfoss 132X9219 - VLT Refrigeration Drive FC 103 (90 kW / 125 HP, IP55, 380-480V)

  • Frequency converter
  • VLT® Refrigeration Drive FC-103
  • 90 KW / 125 HP,
  • Three phase, 380 - 480 VAC, IP55 / Type12 Backplate
  • RFI filter Class A1 / B
  • Safe Stop
  • Graphical Loc. Cont. Panel
  • Coated PCB, Mains Disconnect
  • No adaptation
  • Condition Based Monitoring CBM
  • Modbus TCP MCA 122, MCB-115 Programmable I/O
  • MCB-113 Ext. Relay Card, 24V DC backup
  • Frame: C2
Model code:
FC-103P90KT4P55H1TGC1XXLX1XXAQB5CXRXXD0
Similar products
  • Genuine Danfoss products
  • Danfoss manufacturer warranty
  • Reply within one business day

Product details

Product GroupFC-VLT® Refrigeration Drive
Series103
Power RatingP90K90 KW / 125 HP
PhaseTThree phase
Mains Voltage4380 - 480 VAC
EnclosureP55IP55 / Type12 Backplate
RFI FilterH1RFI filter Class A1 / B
Brake - Safe StopTSafe Stop
LCPGGraphical Loc. Cont. Panel
Coating PCBCCoated PCB
Mains Option1Mains Disconnect
Adaptation AXStandard Cable Entries
Adaptation BXNo adaptation
Software ReleaseLX1XCondition Based Monitoring CBM
Software Language PackXStandard Language Pack
A OptionAQModbus TCP MCA 122
B OptionB5MCB-115 Programmable I/O
C0 Option MCOCXNo C0 option
C1 OptionRMCB-113 Ext. Relay Card
C Option SoftwareXXNo software option
D OptionD024V DC backup
Frame SizeC2
Power 110% (NO) [KW]90
kVA123
Power Loss NO [W]1474
Continuous Current (NO) [A]177
Intermittent Current (NO) [A]195
Continuous Current (NO) [A]160
Intermittent Current (NO) [A]176
Height [mm]780,0
Width w/ no C options [mm]370,0
Depth [mm]332,0
Depth with Option A/B [mm]332,0

Technical data

Motor power90 kW / 125 HP
Mains voltage380 - 480 VAC
PhaseThree-phase
Protection ratingIP55 / Type12 Backplate
Frame sizeC2
RFI filterClass A1/B (EMC C1)
Brake chopperNo
Safe Torque OffYes
Control panelGraphical LCP
PCB coatingCoated PCB
Mains optionMains Disconnect
FieldbusModbus TCP MCA 122
Product typeFrequency converter
Continuous output current177 A
Continuous current (high line)160 A
Intermittent output current195 A
Apparent power123 kVA
Power loss1474 W
Power, normal overload90 kW
Height780 mm
Width370 mm
Depth332 mm
Depth with A/B options332 mm
Net weight62.11 kg
Gross weight65.45 kg
Packed volume207.4 L
EAN5715253244723
ECCN (US)3A999.a

Documents

Operating guides, design guides, certificates and CAD drawings for 132X9219 are available on request. Ask for documents →

Other 90 kW / 125 HP variants in VLT Refrigeration Drive FC 103

Request a quote

Price and delivery time, usually within one business day.

Genuine Danfoss · Manufacturer warranty

We only use your details to answer this request. See our privacy policy.