134F5875
Danfoss 134F5875 - VLT HVAC Drive FC 102 (75 kW / 100 HP, IP21, 525-690V)
- Frequency Converter
- VLT® HVAC Drive FC-102
- (P75K) 75 KW / 100 HP, Specific Ratings: 55kW@525-550V, 75HP@575V, 75kW@690V
- Three phase, 525 - 690 VAC *,IP21 / Type 1
- RFI class A1 (C2)
- No brake chopper
- Graphical Loc. Cont. Panel
- Coated PCB, No Mains Option
- Latest release std. SW.
- Frame: C2
- No A Option, No B Option
- No C1 option, No D option
Model code:
FC-102P75KT7E21H4XGCXXXSXXXXAXBXCXXXXDX
FC-102P75KT7E21H4XGCXXXSXXXXAXBXCXXXXDX
Similar products
- Genuine Danfoss products
- Danfoss manufacturer warranty
- Reply within one business day
Product details
| Product Group | FC- | VLT® HVAC Drive FC- |
| Series | 102 | |
| Power Rating | P75K | (P75K) 75 KW / 100 HP |
| Phase | T | Three phase |
| Mains Voltage | 7 | 525 - 690 VAC * |
| Enclosure | E21 | IP21 / Type 1 |
| RFI Filter | H4 | RFI class A1 (C2) |
| Brake - Safe Stop | X | No brake chopper |
| LCP | G | Graphical Loc. Cont. Panel |
| Coating PCB | C | Coated PCB |
| Mains Option | X | No Mains Option |
| Adaptation A | X | Standard Cable Entries |
| Adaptation B | X | No adaptation |
| Software Release | SXXX | Latest release std. SW. |
| Software Language Pack | X | Standard Language Pack |
| A Option | AX | No A Option |
| B Option | BX | No B Option |
| C0 Option MCO | CX | No C0 option |
| C1 Option | X | No C1 option |
| C Option Software | XX | No software option |
| D Option | DX | No D option |
| Frame Size | C2 | |
| Power 110% (NO) [KW] | 75 | |
| Height [mm] | 780,0 | |
| Width w/ no C options [mm] | 370,0 | |
| Depth [mm] | 332,0 | |
| Depth with Option A/B [mm] | 332,0 | |
| kVA | 99.2 | |
| Power Loss NO [W] | 1200 | |
| Continuous Current (NO) [A] | 87 | |
| Intermittent Current (NO) [A] | 95.7 | |
| Continuous Current (NO) [A] | 83 | |
| Intermittent Current (NO) [A] | 91.3 | |
| Power Rating at 525-550V | 55kW | |
| Power Rating at 575V | 75HP | |
| Power Rating at 690V | 75kW |
Technical data
| Motor power | 75 kW / 100 HP | |
| Mains voltage | 525 - 690 VAC * | |
| Phase | Three-phase | |
| Protection rating | IP21 / Type 1 | |
| Frame size | C2 | |
| RFI filter | Class A1 (EMC C2) | |
| Brake chopper | No | |
| Control panel | Graphical LCP | |
| PCB coating | Coated PCB | |
| Mains option | None | |
| Fieldbus | None | |
| Product type | Frequency converter | |
| Continuous output current | 87 A | |
| Continuous current (high line) | 83 A | |
| Intermittent output current | 95.7 A | |
| Apparent power | 99.2 kVA | |
| Power loss | 1200 W | |
| Power, normal overload | 75 kW | |
| Height | 780 mm | |
| Width | 370 mm | |
| Depth | 332 mm | |
| Depth with A/B options | 332 mm | |
| Net weight | 57.09 kg | |
| Gross weight | 60.43 kg | |
| Packed volume | 228.1 L | |
| EAN | 5710107457335 | |
| ECCN (EU) | Y901 | |
| ECCN (US) | 3A999.a | |
Documents
Operating guides, design guides, certificates and CAD drawings for 134F5875 are available on request. Ask for documents →
Other 75 kW / 100 HP variants in VLT HVAC Drive FC 102
- 134N3504 IP20 · Class A2 · D3H
- 134N9762 IP20 · Class A2 · D3H
- 134X3686 IP20 · Class A2 · D3H
- 134L3567 IP20 · Class A2 · D3H
- 134N1304 IP20 · Class A2 · D3H
- 132N0212 IP20 · Class A2 · D3H
- 134L4698 IP20 · Class A2 · D3H
- 137X2985 IP20 · Class A2 · D3H
- 136G7840 IP20 · Class A2 · D3H
- 134L8330 IP20 · Class A2 · D3H
- 134L2656 IP20 · Class A2 · D3H
- 134H6754 IP20 · Class A2 · D3H
- 134L6798 IP20 · Class A2 · D3H
- 136G0592 IP20 · Class A2 · D3H
- 136G3383 IP21 · Class A2 · D5H
- 134N2680 IP21 · Class A2 · D6H
- 134N1883 IP21 · Class A2 · D1H
- 132X2708 IP21 · Class A2 · D5H
- 134G6373 IP21 · Class A2 · D6H
- 134G5951 IP21 · Class A2 · D1H
- 132X3429 IP21 · Class A2 · D1H
- 134H4807 IP21 · Class A2 · D1H
- 134F0278 IP21 · Class A2 · C2
- 137X3378 IP21 · Class A2 · C2