134F9008
Danfoss 134F9008 - VLT Refrigeration Drive FC 103 (37 kW / 50 HP, IP55, 200-240V)
- Frequency converter
- VLT® Refrigeration Drive FC-103
- 37 KW / 50 HP,
- Three phase, 200 - 240 VAC,IP55 / Type 12
- RFI filter Class A2
- No brake chopper
- Graphical Loc. Cont. Panel
- Not coated PCB, No Mains Option
- Latest release std. SW.
- No A Option, No B Option
- No C1 option, No D option
- Frame: C2
Model code:
FC-103P37KT2E55H2XGXXXXSXXXXAXBXCXXXXDX
FC-103P37KT2E55H2XGXXXXSXXXXAXBXCXXXXDX
Similar products
- Genuine Danfoss products
- Danfoss manufacturer warranty
- Reply within one business day
Product details
| Product Group | FC- | VLT® Refrigeration Drive |
| Series | 103 | |
| Power Rating | P37K | 37 KW / 50 HP |
| Phase | T | Three phase |
| Mains Voltage | 2 | 200 - 240 VAC |
| Enclosure | E55 | IP55 / Type 12 |
| RFI Filter | H2 | RFI filter Class A2 |
| Brake - Safe Stop | X | No brake chopper |
| LCP | G | Graphical Loc. Cont. Panel |
| Coating PCB | X | Not coated PCB |
| Mains Option | X | No Mains Option |
| Adaptation A | X | Standard Cable Entries |
| Adaptation B | X | No adaptation |
| Software Release | SXXX | Latest release std. SW. |
| Software Language Pack | X | Standard Language Pack |
| A Option | AX | No A Option |
| B Option | BX | No B Option |
| C0 Option MCO | CX | No C0 option |
| C1 Option | X | No C1 option |
| C Option Software | XX | No software option |
| D Option | DX | No D option |
| Frame Size | C2 | |
| Power 110% (NO) [KW] | 37 | |
| Height [mm] | 780,0 | |
| Width w/ no C options [mm] | 370,0 | |
| Depth [mm] | 332,0 | |
| Depth with Option A/B [mm] | 332,0 | |
| kVA | 51.5 | |
| Power Loss NO [W] | 1353 | |
| Continuous Current (NO) [A] | 143 | |
| Intermittent Current (NO) [A] | 157 |
Technical data
| Motor power | 37 kW / 50 HP | |
| Mains voltage | 200 - 240 VAC | |
| Phase | Three-phase | |
| Protection rating | IP55 / Type 12 | |
| Frame size | C2 | |
| RFI filter | Class A2 (EMC C3) | |
| Brake chopper | No | |
| Control panel | Graphical LCP | |
| PCB coating | Uncoated | |
| Mains option | None | |
| Fieldbus | None | |
| Product type | Frequency converter | |
| Continuous output current | 143 A | |
| Intermittent output current | 157 A | |
| Apparent power | 51.5 kVA | |
| Power loss | 1353 W | |
| Power, normal overload | 37 kW | |
| Height | 780 mm | |
| Width | 370 mm | |
| Depth | 332 mm | |
| Depth with A/B options | 332 mm | |
| Net weight | 65 kg | |
| Gross weight | 65.3 kg | |
| Packed volume | 228.1 L | |
| EAN | 5710107492770 | |
| ECCN (EU) | Y901 | |
| ECCN (US) | 3A999.a | |
Documents
Operating guides, design guides, certificates and CAD drawings for 134F9008 are available on request. Ask for documents →
Other 37 kW / 50 HP variants in VLT Refrigeration Drive FC 103
- 134G4216 IP20 · Class A1/B · C4
- 134G6094 IP20 · Class A1/B · C4
- 134G4228 IP20 · Class A1/B · C4
- 136H4590 IP20 · Class A1/B · C4
- 134G5191 IP20 · Class A2 · C4
- 135N9293 IP20 · Class A2 · C4
- 134G9602 IP20 · Class A2 · C4
- 134F8179 IP20 · Class A2 · C4
- 134L3673 IP20 · Class A2 · C4
- 134L9065 IP20 · Class A2 · C4
- 137U3747 IP20 · None · C4
- 136N9621 IP20 · Class A1/B · C4
- 136H6104 IP20 · Class A2 · C4
- 136N3400 IP21 · Class A1/B · C2
- 134G9761 IP21 · Class A2 · C2
- 134G9762 IP21 · Class A2 · C2
- 136F8085 IP21 · Class A2 · C2
- 134H4085 IP21 · Class A2 · C2
- 134H4094 IP21 · Class A2 · C2
- 134G4172 IP55 · Class A1/B · C2
- 136L4898 IP55 · Class A1/B · C2
- 136Z7596 IP55 · Class A1/B · C2
- 134F7387 IP55 · Class A1/B · C2
- 135X1036 IP55 · Class A2 · C2