134F9727
Danfoss 134F9727 - VLT AQUA Drive FC 202 (110 kW / 150 HP, IP54, 380-480V)
- Frequency converter
- VLT® AQUA Drive FC-202
- (N110) 110 KW / 150 HP,
- Three phase, 380 - 480 VAC,IP54/Type 12+main shield
- RFI class A1 (C2)
- No brake chopper
- Graphical Loc. Cont. Panel
- Coated PCB, Fuse
- Latest release std. SW.
- Frame: D1H
- No A Option, No B Option
- No C1 option, No D option
Model code:
FC-202N110T4E5MH4XGC7XXSXXXXAXBXCXXXXDX
FC-202N110T4E5MH4XGC7XXSXXXXAXBXCXXXXDX
Similar products
- Genuine Danfoss products
- Danfoss manufacturer warranty
- Reply within one business day
Product details
| Product Group | FC- | VLT® AQUA Drive FC- |
| Series | 202 | |
| Power Rating | N110 | (N110) 110 KW / 150 HP |
| Phase | T | Three phase |
| Mains Voltage | 4 | 380 - 480 VAC |
| Enclosure | E5M | IP54/Type 12+main shield |
| RFI Filter | H4 | RFI class A1 (C2) |
| Brake - Safe Stop | X | No brake chopper |
| LCP | G | Graphical Loc. Cont. Panel |
| Coating PCB | C | Coated PCB |
| Mains Option | 7 | Fuse |
| Adaptation A | X | Standard Cable Entries |
| Adaptation B | X | No adaptation |
| Software Release | SXXX | Latest release std. SW. |
| Software Language Pack | X | Standard Language Pack |
| A Option | AX | No A Option |
| B Option | BX | No B Option |
| C0 Option MCO | CX | No C0 option |
| C1 Option | X | No C1 option |
| C Option Software | XX | No software option |
| D Option | DX | No D option |
| Frame Size | D1H | |
| Power 150% (HO) [KW] | 90 | |
| Power 110% (NO) [KW] | 110 | |
| Height [mm] | 901,0 | |
| Width w/ no C options [mm] | 325,0 | |
| Depth [mm] | 378,0 | |
| Depth with Option A/B [mm] | 378,0 | |
| kVA | 147 | |
| Power Loss NO [W] | 2559 | |
| Power Loss NO [W] | 2261 | |
| Power Loss HO [W] | 2031 | |
| Power Loss HO [W] | 1828 | |
| Continuous Current (NO) [A] | 212 | |
| Intermittent Current (NO) [A] | 233 | |
| Continuous Current (NO) [A] | 190 | |
| Intermittent Current (NO) [A] | 209 | |
| Continuous Current (HO) [A] | 177 | |
| Intermittent Current (HO) [A] | 266 | |
| Continuous Current (HO) [A] | 160 | |
| Intermittent Current (HO) [A] | 240 |
Technical data
| Motor power | 110 kW / 150 HP | |
| Mains voltage | 380 - 480 VAC | |
| Phase | Three-phase | |
| Protection rating | IP54/Type 12+main shield | |
| Frame size | D1H | |
| RFI filter | Class A1 (EMC C2) | |
| Brake chopper | No | |
| Control panel | Graphical LCP | |
| PCB coating | Coated PCB | |
| Mains option | Integrated Fuse | |
| Fieldbus | None | |
| Product type | Frequency converter | |
| Continuous output current | 212 A | |
| Continuous current (high line) | 190 A | |
| Intermittent output current | 233 A | |
| Continuous current (high overload) | 177 A | |
| Apparent power | 147 kVA | |
| Power loss | 2559 W | |
| Power, normal overload | 110 kW | |
| Power, high overload | 90 kW | |
| Height | 901 mm | |
| Width | 325 mm | |
| Depth | 378 mm | |
| Depth with A/B options | 378 mm | |
| Net weight | 75 kg | |
| Gross weight | 80 kg | |
| EAN | 5710107500192 | |
| ECCN (EU) | Y901 | |
| ECCN (US) | 3A999.a | |
Documents
Operating guides, design guides, certificates and CAD drawings for 134F9727 are available on request. Ask for documents →
Other 110 kW / 150 HP variants in VLT AQUA Drive FC 202
- 137X5946 IP20 · Class A2 · D3H
- 137L3158 IP20 · Class A2 · D3H
- 132N4798 IP20 · Class A2 · D3H
- 134H9411 IP20 · Class A1 · D3H
- 134G5423 IP20 · Class A2 · D3H
- 137G4503 IP20 · Class A2 · D3H
- 137N1442 IP20 · Class A2 · D3H
- 137H9202 IP20 · Class A2 · D3H
- 136G7717 IP20 · Class A2 · D3H
- 134H5842 IP20 · Class A2 · D3H
- 134F7803 IP20 · Class A2 · D3H
- 134U7997 IP20 · Class A2 · D3H
- 132X7273 IP20 · Class A2 · D3H
- 137X6621 IP20 · Class A2 · D3H
- 137U1511 IP20 · Class A2 · D3H
- 167F8541 IP20 · Class A2 · D3H
- 137N5199 IP20 · Class A2 · D3H
- 137L8940 IP20 · Class A2 · D3H
- 134F0407 IP20 · Class A2 · D3H
- 132X0504 IP20 · Class A2 · D3H
- 137G6932 IP20 · Class A2 · D3H
- 132X3694 IP20 · Class A2 · D3H
- 132N9209 IP20 · Class A2 · D3H
- 137N2663 IP20 · Class A2 · D3H