Danfoss VLT Refrigeration Drive FC 103 FC-103P90KT4E55H1XGXXXXSXXXXAZBXCXXXXDX
134G1906

Danfoss 134G1906 - VLT Refrigeration Drive FC 103 (90 kW / 125 HP, IP55, 380-480V)

  • Frequency converter
  • VLT® Refrigeration Drive FC-103
  • 90 KW / 125 HP,
  • Three phase, 380 - 480 VAC,IP55 / Type 12
  • RFI filter Class A1 / B
  • No brake chopper
  • Graphical Loc. Cont. Panel
  • Not coated PCB, No Mains Option
  • Latest release std. SW.
  • AK-LonWorks MCA 107, No B Option
  • No C1 option, No D option
  • Frame: C2
Model code:
FC-103P90KT4E55H1XGXXXXSXXXXAZBXCXXXXDX
Similar products
  • Genuine Danfoss products
  • Danfoss manufacturer warranty
  • Reply within one business day

Product details

Product GroupFC-VLT® Refrigeration Drive
Series103
Power RatingP90K90 KW / 125 HP
PhaseTThree phase
Mains Voltage4380 - 480 VAC
EnclosureE55IP55 / Type 12
RFI FilterH1RFI filter Class A1 / B
Brake - Safe StopXNo brake chopper
LCPGGraphical Loc. Cont. Panel
Coating PCBXNot coated PCB
Mains OptionXNo Mains Option
Adaptation AXStandard Cable Entries
Adaptation BXNo adaptation
Software ReleaseSXXXLatest release std. SW.
Software Language PackXStandard Language Pack
A OptionAZAK-LonWorks MCA 107
B OptionBXNo B Option
C0 Option MCOCXNo C0 option
C1 OptionXNo C1 option
C Option SoftwareXXNo software option
D OptionDXNo D option
Frame SizeC2
Power 110% (NO) [KW]90
Height [mm]780,0
Width w/ no C options [mm]370,0
Depth [mm]332,0
Depth with Option A/B [mm]332,0
kVA123
Power Loss NO [W]1474
Continuous Current (NO) [A]177
Intermittent Current (NO) [A]195
Continuous Current (NO) [A]160
Intermittent Current (NO) [A]176

Technical data

Motor power90 kW / 125 HP
Mains voltage380 - 480 VAC
PhaseThree-phase
Protection ratingIP55 / Type 12
Frame sizeC2
RFI filterClass A1/B (EMC C1)
Brake chopperNo
Control panelGraphical LCP
PCB coatingUncoated
Mains optionNone
FieldbusAK-LonWorks MCA 107
Product typeFrequency converter
Continuous output current177 A
Continuous current (high line)160 A
Intermittent output current195 A
Apparent power123 kVA
Power loss1474 W
Power, normal overload90 kW
Height780 mm
Width370 mm
Depth332 mm
Depth with A/B options332 mm
Net weight63.2 kg
Gross weight63.8 kg
Packed volume228.1 L
EAN5710107522064
ECCN (EU)Y901
ECCN (US)3A999.a

Documents

Operating guides, design guides, certificates and CAD drawings for 134G1906 are available on request. Ask for documents →

Other 90 kW / 125 HP variants in VLT Refrigeration Drive FC 103

Request a quote

Price and delivery time, usually within one business day.

Genuine Danfoss · Manufacturer warranty · Worldwide delivery

We only use your details to answer this request. See our privacy policy.