Danfoss VLT HVAC Drive FC 102 FC-102P1K1T4Z55H1TNX1XXSXXXXAXB2CXXXXDX
134H6208

Danfoss 134H6208 - VLT HVAC Drive FC 102 (1.1 kW / 1.5 HP, IP55, 380-480V)

  • Frequency Converter
  • VLT® HVAC Drive FC-102
  • (P1K1) 1.1 KW / 1.5 HP,
  • Three phase, 380 - 480 VAC,IP55 / Type 12 A4 Frame
  • (H1) RFI Class A1/B (C1)
  • Safe Stop
  • Numerical Loc. Cont. Panel
  • Not coated PCB, Mains Disconnect
  • Latest release std. SW.
  • Frame: A4
  • No A Option, MCB-112 PTC Therm. Card
  • No C1 option, No D option
  • ATEX: II (2) G [Ex eb Gb] [Ex db Gb] / II (2) D [Ex tb Db]
Model code:
FC-102P1K1T4Z55H1TNX1XXSXXXXAXB2CXXXXDX
Similar products
  • Genuine Danfoss products
  • Danfoss manufacturer warranty
  • Reply within one business day

Product details

Product GroupFC-VLT® HVAC Drive FC-
Series102
Power RatingP1K1(P1K1) 1.1 KW / 1.5 HP
PhaseTThree phase
Mains Voltage4380 - 480 VAC
EnclosureZ55IP55 / Type 12 A4 Frame
RFI FilterH1(H1) RFI Class A1/B (C1)
Brake - Safe StopTSafe Stop
LCPNNumerical Loc. Cont. Panel
Coating PCBXNot coated PCB
Mains Option1Mains Disconnect
Adaptation AXStandard Cable Entries
Adaptation BXNo adaptation
Software ReleaseSXXXLatest release std. SW.
Software Language PackXStandard Language Pack
A OptionAXNo A Option
B OptionB2MCB-112 PTC Therm. Card
C0 Option MCOCXNo C0 option
C1 OptionXNo C1 option
C Option SoftwareXXNo software option
D OptionDXNo D option
Frame SizeA4
Power 110% (NO) [KW]1.1
Height [mm]391,0
Width w/ no C options [mm]200,0
Depth [mm]177,0
Depth with Option A/B [mm]177,0
kVA2.08
Power Loss NO [W]58
Continuous Current (NO) [A]3
Intermittent Current (NO) [A]3.3
Continuous Current (NO) [A]2.7
Intermittent Current (NO) [A]2.97
ATEX Marking 1ATEX: II (2) G [Ex eb Gb] [Ex
ATEX Marking 2db Gb] / II (2) D [Ex tb Db]

Technical data

Motor power1.1 kW / 1.5 HP
Mains voltage380 - 480 VAC
PhaseThree-phase
Protection ratingIP55 / Type 12 A4 Frame
Frame sizeA4
RFI filterClass A1/B (EMC C1)
Brake chopperNo
Safe Torque OffYes
Control panelNumerical LCP
PCB coatingUncoated
Mains optionMains Disconnect
FieldbusNone
Product typeFrequency converter
Continuous output current3 A
Continuous current (high line)2.7 A
Intermittent output current3.3 A
Apparent power2.08 kVA
Power loss58 W
Power, normal overload1.1 kW
Height391 mm
Width200 mm
Depth177 mm
Depth with A/B options177 mm
Net weight8.28 kg
Gross weight9.05 kg
Packed volume52.4 L
EAN5710107713356
ECCN (EU)Y901
ECCN (US)3A999.a

Documents

Operating guides, design guides, certificates and CAD drawings for 134H6208 are available on request. Ask for documents →

Other 1.1 kW / 1.5 HP variants in VLT HVAC Drive FC 102

Request a quote

Price and delivery time, usually within one business day.

Genuine Danfoss · Manufacturer warranty