Danfoss VLT AutomationDrive FC 302 FC-302N90KT7E5MH2XGC7XXSXXXXA0BXCXXXXD0
134H7988

Danfoss 134H7988 - VLT AutomationDrive FC 302 (90 kW / 125 HP, IP54, 525-690V)

  • Frequency converter
  • VLT® AutomationDrive FC-302
  • (N90K) 90 KW / 125 HP, Specific Ratings: 75kW@525-550V, 100HP@575V, 90kW@690V
  • Three phase, 525 - 690 VAC *,IP54/Type 12+main shield
  • RFI Filter
  • No brake chopper
  • Graphical Loc. Cont. Panel
  • Coated PCB, Fuse
  • Latest release std. SW.
  • Frame: D1H
  • PROFIBUS DP MCA 101, No B Option
  • No C1 option, MCB-107 24V DC backup
Model code:
FC-302N90KT7E5MH2XGC7XXSXXXXA0BXCXXXXD0
Similar products
  • Genuine Danfoss products
  • Danfoss manufacturer warranty
  • Reply within one business day

Product details

Product GroupFC-VLT® AutomationDrive FC-
Series302
Power RatingN90K(N90K) 90 KW / 125 HP
PhaseTThree phase
Mains Voltage7525 - 690 VAC *
EnclosureE5MIP54/Type 12+main shield
RFI FilterH2RFI Filter
Brake - Safe StopXNo brake chopper
LCPGGraphical Loc. Cont. Panel
Coating PCBCCoated PCB
Mains Option7Fuse
Adaptation AXStandard Cable Entries
Adaptation BXNo adaptation
Software ReleaseSXXXLatest release std. SW.
Software Language PackXStandard Language Pack
A OptionA0PROFIBUS DP MCA 101
B OptionBXNo B Option
C0 Option MCOCXNo C0 option
C1 OptionXNo C1 option
C Option SoftwareXXNo software option
D OptionD0MCB-107 24V DC backup
Frame SizeD1H
Power 150% (HO) [KW]90
Power 110% (NO) [KW]110
Height [mm]901,0
Width w/ no C options [mm]325,0
Depth [mm]378,0
Depth with Option A/B [mm]378,0
kVA129
Power Loss NO [W]1740
Power Loss NO [W]1798
Power Loss HO [W]1430
Power Loss HO [W]1480
Continuous Current (NO) [A]137
Intermittent Current (NO) [A]151
Continuous Current (NO) [A]131
Intermittent Current (NO) [A]144
Continuous Current (HO) [A]113
Intermittent Current (HO) [A]170
Continuous Current (HO) [A]108
Intermittent Current (HO) [A]162
Power Rating at 525-550V75kW
Power Rating at 575V100HP
Power Rating at 690V90kW

Technical data

Motor power90 kW / 125 HP
Mains voltage525 - 690 VAC *
PhaseThree-phase
Protection ratingIP54/Type 12+main shield
Frame sizeD1H
RFI filterClass A2 (EMC C3)
Brake chopperNo
Safe Torque OffYes
Control panelGraphical LCP
PCB coatingCoated PCB
Mains optionIntegrated Fuse
FieldbusPROFIBUS DP MCA 101
Product typeFrequency converter
Continuous output current137 A
Continuous current (high line)131 A
Intermittent output current151 A
Continuous current (high overload)113 A
Apparent power129 kVA
Power loss1740 W
Power, normal overload110 kW
Power, high overload90 kW
Height901 mm
Width325 mm
Depth378 mm
Depth with A/B options378 mm
Net weight71 kg
Gross weight76 kg
EAN5710107731206
ECCN (EU)Y901
ECCN (US)3A999.a

Documents

Operating guides, design guides, certificates and CAD drawings for 134H7988 are available on request. Ask for documents →

Other 90 kW / 125 HP variants in VLT AutomationDrive FC 302

Request a quote

Price and delivery time, usually within one business day.

Genuine Danfoss · Manufacturer warranty · Worldwide delivery

We only use your details to answer this request. See our privacy policy.