134L1972
Danfoss 134L1972 - VLT HVAC Drive FC 102 (1200 kW / 1600 HP, IP54, 525-690V)
- Frequency Converter
- VLT® HVAC Drive FC-102
- (P1M2) 1.2 MW / 1600 HP, Three phase
- 525 - 690 VAC *, (E54) IP54 / Type 12
- 12 Pulse + Class A2 RFI
- No brake chopper
- Graphical Loc. Cont. Panel
- Coated PCB, No Mains Option
- Latest release std. SW.
- Frame:
- No C1 option, No D option
- No A Option, No B Option
Model code:
FC-102P1M2T7E54B2XGCXXXSXXXXAXBXCXXXXDX
FC-102P1M2T7E54B2XGCXXXSXXXXAXBXCXXXXDX
Similar products
- Genuine Danfoss products
- Danfoss manufacturer warranty
- Reply within one business day
Product details
| Product Group | FC- | VLT® HVAC Drive FC- |
| Series | 102 | |
| Power Rating | P1M2 | (P1M2) 1.2 MW / 1600 HP |
| Phase | T | Three phase |
| Mains Voltage | 7 | 525 - 690 VAC * |
| Enclosure | E54 | (E54) IP54 / Type 12 |
| RFI Filter | B2 | 12 Pulse + Class A2 RFI |
| Brake - Safe Stop | X | No brake chopper |
| LCP | G | Graphical Loc. Cont. Panel |
| Coating PCB | C | Coated PCB |
| Mains Option | X | No Mains Option |
| Adaptation A | X | Standard Cable Entries |
| Adaptation B | X | No adaptation |
| Software Release | SXXX | Latest release std. SW. |
| Software Language Pack | X | Standard Language Pack |
| A Option | AX | No A Option |
| B Option | BX | No B Option |
| C0 Option MCO | CX | No C0 option |
| C1 Option | X | No C1 option |
| C Option Software | XX | No software option |
| D Option | DX | No D option |
| Power 110% (NO) [KW] | 1200 | |
| kVA | 1506 | |
| Power Loss NO [W] | 16190 | |
| Power Loss NO [W] | 16821 | |
| Continuous Current (NO) [A] | 1317 | |
| Intermittent Current (NO) [A] | 1449 | |
| Continuous Current (NO) [A] | 1260 | |
| Intermittent Current (NO) [A] | 1386 |
Technical data
| Motor power | 1200 kW / 1600 HP | |
| Mains voltage | 525 - 690 VAC * | |
| Phase | Three-phase | |
| Protection rating | IP54 / Type 12 | |
| RFI filter | Class A2 (EMC C3) | |
| Brake chopper | No | |
| Control panel | Graphical LCP | |
| PCB coating | Coated PCB | |
| Mains option | None | |
| Fieldbus | None | |
| Product type | Frequency converter | |
| Continuous output current | 1317 A | |
| Continuous current (high line) | 1260 A | |
| Intermittent output current | 1449 A | |
| Apparent power | 1506 kVA | |
| Power loss | 16190 W | |
| Power, normal overload | 1200 kW | |
| Net weight | 1260 kg | |
| Gross weight | 1260.3 kg | |
| Packed volume | 0 L | |
| EAN | 5710107771271 | |
| ECCN (US) | 3A999 | |
Documents
Operating guides, design guides, certificates and CAD drawings for 134L1972 are available on request. Ask for documents →
Other 1200 kW / 1600 HP variants in VLT HVAC Drive FC 102
- 134F6177 IP21 · Class A2 · F13
- 134H0226 IP21 · Class A2 · F13
- 134H2067 IP21 · Class A2
- 134N0025 IP21 · Class A2 · F13
- 131N6917 IP21 · Class A2 · F4
- 131N4864 IP21 · Class A2 · F2
- 131X0507 IP21 · Class A2 · F4
- 134H1916 IP21 · Class A2 · F4
- 136Z2694 IP21 · Class A2 · F4
- 131G6723 IP21 · Class A2 · F4
- 137G4352 IP21 · Class A2 · F2
- 131G6718 IP21 · Class A2 · F2
- 136Z2693 IP21 · Class A2 · F2
- 135U5594 IP21 · Class A2 · F4
- 131X3962 IP21 · Class A2 · F4
- 132L6913 IP21 · Class A2 · F4
- 131X1725 IP21 · Class A2 · F4
- 131U9492 IP21 · Class A2 · F4
- 131L9394 IP21 · Class A2 · F4
- 131X3961 IP21 · Class A2 · F2
- 131N1462 IP21 · Class A2 · F2
- 134N6503 IP21 · Class A2 · F2
- 131N0780 IP21 · Class A2 · F4
- 131X5990 IP21 · Class A2 · F4