Danfoss VLT Decentral Drive FCD 302 FCD302P2K2T4W66H1X3XMECXXXXXA0BXXXXXXDX
134L3352

Danfoss 134L3352 - VLT Decentral Drive FCD 302 (2.2 kW / 3 HP, IP66, 380-480V)

  • VLT® Decentral Drive FCD 302
  • 2.2 kW / 3.0 HP, 380-480VAC (Three phased),Standard White IP66/NEMA4X,
  • RFI Class A1/C2, No brake, Compl. large stand alone, No brackets,
  • Metric threads, Service switch mains side, With display connector
Model code:
FCD302P2K2T4W66H1X3XMECXXXXXA0BXXXXXXDX
Similar products
  • Genuine Danfoss products
  • Danfoss manufacturer warranty
  • Reply within one business day

Product details

Product GroupFCDVLT® DecentralDrive FCD
VLT Series302
Power RatingP2K22.2 kW / 3.0 HP
Mains VoltageT4380-480VAC (Three phased)
EnclosureW66Standard White IP66/NEMA4X
RFI FilterH1RFI Class A1/C2
BrakeXNo brake
Hardware Configuration3Compl. large stand alone
BracketsXNo brackets
ThreadsMMetric threads
Switch OptionEService switch mains side
DisplayCWith display connector
Sensor PlugsXNo sensor plugs
Motor PlugXNo motor plug
Mains PlugXNo mains plug
Fieldbus PlugXNo fieldbus plug
ReservedXReserved
A OptionA0Profibus DP
B OptionBXNo B option
Reserved for SWXXXXXReserved for SW
D OptionDXNo option
FCD302 Frame SizeMF2(MF2) MF2

Technical data

Motor power2.2 kW / 3 HP
Mains voltage380-480VAC (Three phased)
PhaseThree-phase
Protection ratingStandard White IP66/NEMA4X
Frame sizeMF2
RFI filterClass A1 (EMC C2)
Brake chopperNo
Control panelDisplay connector
FieldbusProfibus DP
Product typeDecentral drive
Net weight13.9 kg
Gross weight14.2 kg
EAN5710107785117
ECCN (EU)Y901
ECCN (US)3A999.a

Documents

Operating guides, design guides, certificates and CAD drawings for 134L3352 are available on request. Ask for documents →

Other 2.2 kW / 3 HP variants in VLT Decentral Drive FCD 302

Request a quote

Price and delivery time, usually within one business day.

Genuine Danfoss · Manufacturer warranty · Worldwide delivery

We only use your details to answer this request. See our privacy policy.