Danfoss VLT AutomationDrive FC 302 FC-302P400T5E5MN2XGC7XXSXXXXA0BRCXXXXD0
134N1215

Danfoss 134N1215 - VLT AutomationDrive FC 302 (400 kW / 550 HP, IP54, 380-500V)

  • Frequency converter
  • VLT® AutomationDrive FC-302
  • (P400) 400 KW / 550 HP, Three phase
  • 380 - 500 VAC, IP54/Type 12+main shield
  • LHD - AAF006 filter + A2 RFI
  • No brake chopper
  • Graphical Loc. Cont. Panel
  • Coated PCB, Fuse
  • Latest release std. SW.
  • Frame: E9
  • No C1 option, MCB-107 24V DC backup
  • PROFIBUS DP MCA 101, MCB-102 Encoder Option
Model code:
FC-302P400T5E5MN2XGC7XXSXXXXA0BRCXXXXD0
Similar products
  • Genuine Danfoss products
  • Danfoss manufacturer warranty
  • Reply within one business day

Product details

Product GroupFC-VLT® AutomationDrive FC-
Series302
Power RatingP400(P400) 400 KW / 550 HP
PhaseTThree phase
Mains Voltage5380 - 500 VAC
EnclosureE5MIP54/Type 12+main shield
RFI FilterN2LHD - AAF006 filter + A2 RFI
Brake - Safe StopXNo brake chopper
LCPGGraphical Loc. Cont. Panel
Coating PCBCCoated PCB
Mains Option7Fuse
Adaptation AXStandard Cable Entries
Adaptation BXNo adaptation
Software ReleaseSXXXLatest release std. SW.
Software Language PackXStandard Language Pack
A OptionA0PROFIBUS DP MCA 101
B OptionBRMCB-102 Encoder Option
C0 Option MCOCXNo C0 option
C1 OptionXNo C1 option
C Option SoftwareXXNo software option
D OptionD0MCB-107 24V DC backup
Frame SizeE9
Power 150% (HO) [KW]400
Power 110% (NO) [KW]450
Height [mm]2000,0
Width w/ no C options [mm]1200,0
Depth [mm]500,0
Depth with Option A/B [mm]500,0
kVA482
Power Loss NO [W]18447
Power Loss NO [W]16962
Continuous Current (NO) [A]800
Intermittent Current (NO) [A]880
Continuous Current (NO) [A]730
Intermittent Current (NO) [A]803
Continuous Current (HO) [A]695
Intermittent Current (HO) [A]1042
Continuous Current (HO) [A]678
Intermittent Current (HO) [A]1017

Technical data

Motor power400 kW / 550 HP
Mains voltage380 - 500 VAC
PhaseThree-phase
Protection ratingIP54/Type 12+main shield
Frame sizeE9
RFI filterClass A2 (EMC C3)
Brake chopperNo
Safe Torque OffYes
Control panelGraphical LCP
PCB coatingCoated PCB
Mains optionIntegrated Fuse
FieldbusPROFIBUS DP MCA 101
Product typeFrequency converter
Continuous output current800 A
Continuous current (high line)730 A
Intermittent output current880 A
Continuous current (high overload)695 A
Apparent power482 kVA
Power loss18447 W
Power, normal overload450 kW
Power, high overload400 kW
Height2000 mm
Width1200 mm
Depth500 mm
Depth with A/B options500 mm
Net weight313 kg
Gross weight313.3 kg
Packed volume0 L
EAN5710107864393
ECCN (EU)X.A.I.003
ECCN (US)3A999

Documents

Operating guides, design guides, certificates and CAD drawings for 134N1215 are available on request. Ask for documents →

Other 400 kW / 550 HP variants in VLT AutomationDrive FC 302

Request a quote

Price and delivery time, usually within one business day.

Genuine Danfoss · Manufacturer warranty · Worldwide delivery