Danfoss VLT HVAC Drive FC 102 FC-102N110T4E5MH2TGCXXXSXXXXALB4CXXXXD0
134N4390

Danfoss 134N4390 - VLT HVAC Drive FC 102 (110 kW / 150 HP, IP54, 380-480V)

  • Frequency Converter
  • VLT® HVAC Drive FC-102
  • (N110) 110 KW / 150 HP,
  • Three phase, 380 - 480 VAC,IP54/Type 12+main shield
  • RFI Filter
  • Safe Stop
  • Graphical Loc. Cont. Panel
  • Coated PCB, No Mains Option
  • Latest release std. SW.
  • Frame: D1H
  • PROFINET MCA 120, MCB-114 VLT Sensor Input
  • No C1 option, MCB-107 24V DC backup
Model code:
FC-102N110T4E5MH2TGCXXXSXXXXALB4CXXXXD0
Similar products
  • Genuine Danfoss products
  • Danfoss manufacturer warranty
  • Reply within one business day

Product details

Product GroupFC-VLT® HVAC Drive FC-
Series102
Power RatingN110(N110) 110 KW / 150 HP
PhaseTThree phase
Mains Voltage4380 - 480 VAC
EnclosureE5MIP54/Type 12+main shield
RFI FilterH2RFI Filter
Brake - Safe StopTSafe Stop
LCPGGraphical Loc. Cont. Panel
Coating PCBCCoated PCB
Mains OptionXNo Mains Option
Adaptation AXStandard Cable Entries
Adaptation BXNo adaptation
Software ReleaseSXXXLatest release std. SW.
Software Language PackXStandard Language Pack
A OptionALPROFINET MCA 120
B OptionB4MCB-114 VLT Sensor Input
C0 Option MCOCXNo C0 option
C1 OptionXNo C1 option
C Option SoftwareXXNo software option
D OptionD0MCB-107 24V DC backup
Frame SizeD1H
Power 110% (NO) [KW]110
Height [mm]901,0
Width w/ no C options [mm]325,0
Depth [mm]378,0
Depth with Option A/B [mm]378,0
kVA147
Power Loss NO [W]2555
Power Loss NO [W]2257
Continuous Current (NO) [A]212
Intermittent Current (NO) [A]233
Continuous Current (NO) [A]190
Intermittent Current (NO) [A]209

Technical data

Motor power110 kW / 150 HP
Mains voltage380 - 480 VAC
PhaseThree-phase
Protection ratingIP54/Type 12+main shield
Frame sizeD1H
RFI filterClass A2 (EMC C3)
Brake chopperNo
Safe Torque OffYes
Control panelGraphical LCP
PCB coatingCoated PCB
Mains optionNone
FieldbusPROFINET MCA 120
Product typeFrequency converter
Continuous output current212 A
Continuous current (high line)190 A
Intermittent output current233 A
Apparent power147 kVA
Power loss2555 W
Power, normal overload110 kW
Height901 mm
Width325 mm
Depth378 mm
Depth with A/B options378 mm
Net weight129 kg
Gross weight129.3 kg
EAN5710107896431
ECCN (EU)Y901
ECCN (US)3A999.a

Documents

Operating guides, design guides, certificates and CAD drawings for 134N4390 are available on request. Ask for documents →

Other 110 kW / 150 HP variants in VLT HVAC Drive FC 102

Request a quote

Price and delivery time, usually within one business day.

Genuine Danfoss · Manufacturer warranty