Danfoss VLT HVAC Drive FC 102 FC-102P1M2T7E54B2UGC3XXSXXXXA0BPCXXXXDX
134N7413

Danfoss 134N7413 - VLT HVAC Drive FC 102 (1200 kW / 1600 HP, IP54, 525-690V)

  • Frequency Converter
  • VLT® HVAC Drive FC-102
  • (P1M2) 1.2 MW / 1600 HP, Three phase
  • 525 - 690 VAC *, (E54) IP54 / Type 12
  • 12 Pulse + Class A2 RFI
  • Brake chopper + Safe stop
  • Graphical Loc. Cont. Panel
  • Coated PCB, Mains Disconnect + Fuse
  • Latest release std. SW.
  • Frame: F13
  • No C1 option, No D option
  • PROFIBUS DP MCA 101, MCB-105 Relay Card
Model code:
FC-102P1M2T7E54B2UGC3XXSXXXXA0BPCXXXXDX
Similar products
  • Genuine Danfoss products
  • Danfoss manufacturer warranty
  • Reply within one business day

Product details

Product GroupFC-VLT® HVAC Drive FC-
Series102
Power RatingP1M2(P1M2) 1.2 MW / 1600 HP
PhaseTThree phase
Mains Voltage7525 - 690 VAC *
EnclosureE54(E54) IP54 / Type 12
RFI FilterB212 Pulse + Class A2 RFI
Brake - Safe StopUBrake chopper + Safe stop
LCPGGraphical Loc. Cont. Panel
Coating PCBCCoated PCB
Mains Option3Mains Disconnect + Fuse
Adaptation AXStandard Cable Entries
Adaptation BXNo adaptation
Software ReleaseSXXXLatest release std. SW.
Software Language PackXStandard Language Pack
A OptionA0PROFIBUS DP MCA 101
B OptionBPMCB-105 Relay Card
C0 Option MCOCXNo C0 option
C1 OptionXNo C1 option
C Option SoftwareXXNo software option
D OptionDXNo D option
Frame SizeF13
Power 110% (NO) [KW]1200
Height [mm]2280,0
Width w/ no C options [mm]2802,0
Depth [mm]607,0
Depth with Option A/B [mm]607,0
kVA1506
Power Loss NO [W]16190
Power Loss NO [W]16821
Continuous Current (NO) [A]1317
Intermittent Current (NO) [A]1449
Continuous Current (NO) [A]1260
Intermittent Current (NO) [A]1386

Technical data

Motor power1200 kW / 1600 HP
Mains voltage525 - 690 VAC *
PhaseThree-phase
Protection ratingIP54 / Type 12
Frame sizeF13
RFI filterClass A2 (EMC C3)
Brake chopperYes
Safe Torque OffYes
Control panelGraphical LCP
PCB coatingCoated PCB
Mains optionMains Disconnect + Fuse
FieldbusPROFIBUS DP MCA 101
Product typeFrequency converter
Continuous output current1317 A
Continuous current (high line)1260 A
Intermittent output current1449 A
Apparent power1506 kVA
Power loss16190 W
Power, normal overload1200 kW
Height2280 mm
Width2802 mm
Depth607 mm
Depth with A/B options607 mm
Net weight1260 kg
Gross weight1260.3 kg
Packed volume0 L
EAN5710107926961
ECCN (US)3A999

Documents

Operating guides, design guides, certificates and CAD drawings for 134N7413 are available on request. Ask for documents →

Other 1200 kW / 1600 HP variants in VLT HVAC Drive FC 102

Request a quote

Price and delivery time, usually within one business day.

Genuine Danfoss · Manufacturer warranty · Worldwide delivery

We only use your details to answer this request. See our privacy policy.