Danfoss VLT HVAC Drive FC 102 FC-102N315T7E5MH2XGC7XXSXXXXAXB0CXXXXDX
134U0149

Danfoss 134U0149 - VLT HVAC Drive FC 102 (315 kW / 450 HP, IP54, 525-690V)

  • Frequency Converter
  • VLT® HVAC Drive FC-102
  • (N315) 315 KW / 450 HP, Specific Ratings: 250kW@525-550V, 350HP@575V, 315kW@690V
  • Three phase, 525 - 690 VAC *,IP54/Type 12+main shield
  • RFI Filter
  • No brake chopper
  • Graphical Loc. Cont. Panel
  • Coated PCB, Fuse
  • Latest release std. SW.
  • Frame: D2H
  • No A Option, MCB-109 I/O, RTC Back-up
  • No C1 option, No D option
Model code:
FC-102N315T7E5MH2XGC7XXSXXXXAXB0CXXXXDX
Similar products
  • Genuine Danfoss products
  • Danfoss manufacturer warranty
  • Reply within one business day

Product details

Product GroupFC-VLT® HVAC Drive FC-
Series102
Power RatingN315(N315) 315 KW / 450 HP
PhaseTThree phase
Mains Voltage7525 - 690 VAC *
EnclosureE5MIP54/Type 12+main shield
RFI FilterH2RFI Filter
Brake - Safe StopXNo brake chopper
LCPGGraphical Loc. Cont. Panel
Coating PCBCCoated PCB
Mains Option7Fuse
Adaptation AXStandard Cable Entries
Adaptation BXNo adaptation
Software ReleaseSXXXLatest release std. SW.
Software Language PackXStandard Language Pack
A OptionAXNo A Option
B OptionB0MCB-109 I/O, RTC Back-up
C0 Option MCOCXNo C0 option
C1 OptionXNo C1 option
C Option SoftwareXXNo software option
D OptionDXNo D option
Frame SizeD2H
Power 110% (NO) [KW]315
Height [mm]1060,0
Width w/ no C options [mm]420,0
Depth [mm]378,0
Depth with Option A/B [mm]378,0
kVA411
Power Loss NO [W]4460
Power Loss NO [W]4610
Continuous Current (NO) [A]360
Intermittent Current (NO) [A]396
Continuous Current (NO) [A]344
Intermittent Current (NO) [A]378
Power Rating at 525-550V250kW
Power Rating at 575V350HP
Power Rating at 690V315kW

Technical data

Motor power315 kW / 450 HP
Mains voltage525 - 690 VAC *
PhaseThree-phase
Protection ratingIP54/Type 12+main shield
Frame sizeD2H
RFI filterClass A2 (EMC C3)
Brake chopperNo
Control panelGraphical LCP
PCB coatingCoated PCB
Mains optionIntegrated Fuse
FieldbusNone
Product typeFrequency converter
Continuous output current360 A
Continuous current (high line)344 A
Intermittent output current396 A
Apparent power411 kVA
Power loss4460 W
Power, normal overload315 kW
Height1060 mm
Width420 mm
Depth378 mm
Depth with A/B options378 mm
Net weight119 kg
Gross weight139 kg
EAN5710107961351
ECCN (EU)Y901
ECCN (US)3A999.a

Documents

Operating guides, design guides, certificates and CAD drawings for 134U0149 are available on request. Ask for documents →

Other 315 kW / 450 HP variants in VLT HVAC Drive FC 102

Request a quote

Price and delivery time, usually within one business day.

Genuine Danfoss · Manufacturer warranty

We only use your details to answer this request. See our privacy policy.