134U5587
Danfoss 134U5587 - VLT HVAC Drive FC 102 (18.5 kW / 25 HP, IP55, 525-690V)
- Frequency Converter
- VLT® HVAC Drive FC-102
- (P18K) 18.5 KW / 25 HP, Specific Ratings: 15kW@525-550V, 20HP@575V, 18.5kW@690V
- Three phase, 525 - 690 VAC *,IP55 / Type 12
- RFI Filter
- Brake chopper + Safe stop
- Graphical Loc. Cont. Panel
- Coated PCB, No Mains Option
- Latest release std. SW.
- Frame: B2
- No A Option, No B Option
- No C1 option, No D option
Model code:
FC-102P18KT7E55H2UGCXOXSXXXXAXBXCXXXXDX
FC-102P18KT7E55H2UGCXOXSXXXXAXBXCXXXXDX
Similar products
- Genuine Danfoss products
- Danfoss manufacturer warranty
- Reply within one business day
Product details
| Product Group | FC- | VLT® HVAC Drive FC- |
| Series | 102 | |
| Power Rating | P18K | (P18K) 18.5 KW / 25 HP |
| Phase | T | Three phase |
| Mains Voltage | 7 | 525 - 690 VAC * |
| Enclosure | E55 | IP55 / Type 12 |
| RFI Filter | H2 | RFI Filter |
| Brake - Safe Stop | U | Brake chopper + Safe stop |
| LCP | G | Graphical Loc. Cont. Panel |
| Coating PCB | C | Coated PCB |
| Mains Option | X | No Mains Option |
| Adaptation A | O | Metric thread cable entry |
| Adaptation B | X | No adaptation |
| Software Release | SXXX | Latest release std. SW. |
| Software Language Pack | X | Standard Language Pack |
| A Option | AX | No A Option |
| B Option | BX | No B Option |
| C0 Option MCO | CX | No C0 option |
| C1 Option | X | No C1 option |
| C Option Software | XX | No software option |
| D Option | DX | No D option |
| Frame Size | B2 | |
| Power 110% (NO) [KW] | 18.5 | |
| Height [mm] | 664,0 | |
| Width w/ no C options [mm] | 243,0 | |
| Depth [mm] | 261,0 | |
| Depth with Option A/B [mm] | 261,0 | |
| kVA | 26.3 | |
| Power Loss NO [W] | 335 | |
| Continuous Current (NO) [A] | 23 | |
| Intermittent Current (NO) [A] | 25.3 | |
| Continuous Current (NO) [A] | 22 | |
| Intermittent Current (NO) [A] | 24.2 | |
| Power Rating at 525-550V | 15kW | |
| Power Rating at 575V | 20HP | |
| Power Rating at 690V | 18.5kW |
Technical data
| Motor power | 18.5 kW / 25 HP | |
| Mains voltage | 525 - 690 VAC * | |
| Phase | Three-phase | |
| Protection rating | IP55 / Type 12 | |
| Frame size | B2 | |
| RFI filter | Class A2 (EMC C3) | |
| Brake chopper | Yes | |
| Safe Torque Off | Yes | |
| Control panel | Graphical LCP | |
| PCB coating | Coated PCB | |
| Mains option | None | |
| Fieldbus | None | |
| Product type | Frequency converter | |
| Continuous output current | 23 A | |
| Continuous current (high line) | 22 A | |
| Intermittent output current | 25.3 A | |
| Apparent power | 26.3 kVA | |
| Power loss | 335 W | |
| Power, normal overload | 18.5 kW | |
| Height | 664 mm | |
| Width | 243 mm | |
| Depth | 261 mm | |
| Depth with A/B options | 261 mm | |
| Net weight | 26.44 kg | |
| Gross weight | 30 kg | |
| Packed volume | 105.7 L | |
| EAN | 5710108016241 | |
| ECCN (EU) | Y901 | |
| ECCN (US) | 3A999.a | |
Documents
Operating guides, design guides, certificates and CAD drawings for 134U5587 are available on request. Ask for documents →
Other 18.5 kW / 25 HP variants in VLT HVAC Drive FC 102
- 136X2600 IP20 · Class A1 · B4
- 135N9156 IP20 · Class A1 · B4
- 134L6812 IP20 · Class A1 · B4
- 134U4447 IP20 · Class A1 · B4
- 136G0588 IP20 · Class A1 · B4
- 135X5144 IP20 · Class A2 · B4
- 136N2523 IP20 · Class A2 · B4
- 134U3229 IP20 · Class A2 · B4
- 134L8438 IP20 · Class A2 · B4
- 135X5765 IP21 · Class A2 · B2
- 134G4585 IP21 · Class A2 · B2
- 132L3828 IP21 · Class A2 · B2
- 131X9263 IP21 · Class A2 · B2
- 137H8051 IP21 · Class A2 · B2
- 134N9729 IP21 · Class A2 · B2
- 131Z4260 IP21 · Class A2 · B2
- 134G2862 IP21 · Class A2 · B2
- 134F3746 IP21 · Class A1 · B2
- 134F3815 IP21 · Class A1 · B2
- 134X4765 IP21 · Class A1 · B2
- 134U0162 IP21 · Class A1 · B2
- 134F1854 IP21 · Class A1 · B2
- 134N9804 IP21 · Class A2 · B2
- 131Z5363 IP21 · Class A2 · B2