Danfoss VLT Refrigeration Drive FC 103 FC-103N160T4E20H2TGC7XXSXXXXA0BXCXXXXDX
134X0162

Danfoss 134X0162 - VLT Refrigeration Drive FC 103 (160 kW / 250 HP, IP20, 380-480V)

  • Frequency converter
  • VLT® Refrigeration Drive FC-103
  • (N160) 160 KW / 250 HP,
  • Three phase, 380 - 480 VAC,(E20) IP20 / Chassis
  • RFI filter Class A2
  • Safe Stop
  • Graphical Loc. Cont. Panel
  • Coated PCB, Fuse
  • Latest release std. SW.
  • PROFIBUS DP MCA 101, No B Option
  • No C1 option, No D option
  • Frame: D3H
Model code:
FC-103N160T4E20H2TGC7XXSXXXXA0BXCXXXXDX
Similar products
  • Genuine Danfoss products
  • Danfoss manufacturer warranty
  • Reply within one business day

Product details

Product GroupFC-VLT® Refrigeration Drive
Series103
Power RatingN160(N160) 160 KW / 250 HP
PhaseTThree phase
Mains Voltage4380 - 480 VAC
EnclosureE20(E20) IP20 / Chassis
RFI FilterH2RFI filter Class A2
Brake - Safe StopTSafe Stop
LCPGGraphical Loc. Cont. Panel
Coating PCBCCoated PCB
Mains Option7Fuse
Adaptation AXStandard Cable Entries
Adaptation BXNo adaptation
Software ReleaseSXXXLatest release std. SW.
Software Language PackXStandard Language Pack
A OptionA0PROFIBUS DP MCA 101
B OptionBXNo B Option
C0 Option MCOCXNo C0 option
C1 OptionXNo C1 option
C Option SoftwareXXNo software option
D OptionDXNo D option
Frame SizeD3H
Power 110% (NO) [KW]160
Height w/ Regen/Loadshare [mm]1004,0
Height [mm]909,0
Width w/ no C options [mm]250,0
Depth [mm]375,0
Depth with Option A/B [mm]375,0
kVA218
Power Loss NO [W]3764
Power Loss NO [W]3628
Continuous Current (NO) [A]315
Intermittent Current (NO) [A]346
Continuous Current (NO) [A]302
Intermittent Current (NO) [A]332

Technical data

Motor power160 kW / 250 HP
Mains voltage380 - 480 VAC
PhaseThree-phase
Protection ratingIP20 / Chassis
Frame sizeD3H
RFI filterClass A2 (EMC C3)
Brake chopperNo
Safe Torque OffYes
Control panelGraphical LCP
PCB coatingCoated PCB
Mains optionIntegrated Fuse
FieldbusPROFIBUS DP MCA 101
Product typeFrequency converter
Continuous output current315 A
Continuous current (high line)302 A
Intermittent output current346 A
Apparent power218 kVA
Power loss3764 W
Power, normal overload160 kW
Height909 mm
Height with regen/loadshare1004 mm
Width250 mm
Depth375 mm
Depth with A/B options375 mm
Net weight62 kg
Gross weight62.3 kg
EAN5710108062286
ECCN (EU)Y901
ECCN (US)3A999.a

Documents

Operating guides, design guides, certificates and CAD drawings for 134X0162 are available on request. Ask for documents →

Other 160 kW / 250 HP variants in VLT Refrigeration Drive FC 103

Request a quote

Price and delivery time, usually within one business day.

Genuine Danfoss · Manufacturer warranty · Worldwide delivery

We only use your details to answer this request. See our privacy policy.