Danfoss VLT AutomationDrive FC 302 FC-302P2K2T6P55HXXGCXXXSXXXXA0B2CXXXXD0
134X4055

Danfoss 134X4055 - VLT AutomationDrive FC 302 (2.2 kW / 3 HP, IP55, 525-600V)

  • Frequency converter
  • VLT® AutomationDrive FC-302
  • (P2K2) 2.2 KW / 3.0 HP,
  • Three phase, 525 - 600 VAC,IP55 / Type12 Backplate
  • No RFI Filter
  • No brake chopper
  • Graphical Loc. Cont. Panel
  • Coated PCB, No Mains Option
  • Latest release std. SW.
  • Frame: A5
  • PROFIBUS DP MCA 101, MCB-112 PTC Therm. Card
  • No C1 option, MCB-107 24V DC backup
  • ATEX: II (2) G [Ex eb Gb] [Ex db Gb] / II (2) D [Ex tb Db]
Model code:
FC-302P2K2T6P55HXXGCXXXSXXXXA0B2CXXXXD0
Similar products
  • Genuine Danfoss products
  • Danfoss manufacturer warranty
  • Reply within one business day

Product details

Product GroupFC-VLT® AutomationDrive FC-
Series302
Power RatingP2K2(P2K2) 2.2 KW / 3.0 HP
PhaseTThree phase
Mains Voltage6525 - 600 VAC
EnclosureP55IP55 / Type12 Backplate
RFI FilterHXNo RFI Filter
Brake - Safe StopXNo brake chopper
LCPGGraphical Loc. Cont. Panel
Coating PCBCCoated PCB
Mains OptionXNo Mains Option
Adaptation AXStandard Cable Entries
Adaptation BXNo adaptation
Software ReleaseSXXXLatest release std. SW.
Software Language PackXStandard Language Pack
A OptionA0PROFIBUS DP MCA 101
B OptionB2MCB-112 PTC Therm. Card
C0 Option MCOCXNo C0 option
C1 OptionXNo C1 option
C Option SoftwareXXNo software option
D OptionD0MCB-107 24V DC backup
Frame SizeA5
Power 160% (HO) [KW]2.2
Height [mm]420,0
Width w/ no C options [mm]242,0
Depth [mm]200,0
Depth with Option A/B [mm]200,0
kVA3.88
Power Loss HO [W]92
Continuous Current (HO) [A]4.1
Intermittent Current (HO) [A]6.56
Continuous Current (HO) [A]3.9
Intermittent Current (HO) [A]6.24
ATEX Marking 1ATEX: II (2) G [Ex eb Gb] [Ex
ATEX Marking 2db Gb] / II (2) D [Ex tb Db]

Technical data

Motor power2.2 kW / 3 HP
Mains voltage525 - 600 VAC
PhaseThree-phase
Protection ratingIP55 / Type12 Backplate
Frame sizeA5
RFI filterNone
Brake chopperNo
Safe Torque OffYes
Control panelGraphical LCP
PCB coatingCoated PCB
Mains optionNone
FieldbusPROFIBUS DP MCA 101
Product typeFrequency converter
Continuous output current4.1 A
Intermittent output current6.56 A
Apparent power3.88 kVA
Power loss92 W
Power, high overload2.2 kW
Height420 mm
Width242 mm
Depth200 mm
Depth with A/B options200 mm
Net weight12.58 kg
Gross weight13.2 kg
EAN5710108101800
ECCN (EU)Y901
ECCN (US)3A999.a

Documents

Operating guides, design guides, certificates and CAD drawings for 134X4055 are available on request. Ask for documents →

Other 2.2 kW / 3 HP variants in VLT AutomationDrive FC 302

Request a quote

Price and delivery time, usually within one business day.

Genuine Danfoss · Manufacturer warranty

We only use your details to answer this request. See our privacy policy.