135N7147
Danfoss 135N7147 - VLT Refrigeration Drive FC 103 (110 kW / 150 HP, IP21, 380-480V)
- Frequency converter
- VLT® Refrigeration Drive FC-103
- (N110) 110 KW / 150 HP,
- Three phase, 380 - 480 VAC,IP21/Type 1+mains shield
- RFI filter Class A2
- Safe Stop
- Graphical Loc. Cont. Panel
- Coated PCB, Mains Disconnect + Fuse
- Latest release std. SW.
- AK-LonWorks MCA 107, No B Option
- No C1 option, 24V DC backup
- Frame: D5H
Model code:
FC-103N110T4E2MH2TGC3XQSXXXXAZBXCXXXXD0
FC-103N110T4E2MH2TGC3XQSXXXXAZBXCXXXXD0
Similar products
- Genuine Danfoss products
- Danfoss manufacturer warranty
- Reply within one business day
Product details
| Product Group | FC- | VLT® Refrigeration Drive |
| Series | 103 | |
| Power Rating | N110 | (N110) 110 KW / 150 HP |
| Phase | T | Three phase |
| Mains Voltage | 4 | 380 - 480 VAC |
| Enclosure | E2M | IP21/Type 1+mains shield |
| RFI Filter | H2 | RFI filter Class A2 |
| Brake - Safe Stop | T | Safe Stop |
| LCP | G | Graphical Loc. Cont. Panel |
| Coating PCB | C | Coated PCB |
| Mains Option | 3 | Mains Disconnect + Fuse |
| Adaptation A | X | Standard Cable Entries |
| Adaptation B | Q | Heat-sink access |
| Software Release | SXXX | Latest release std. SW. |
| Software Language Pack | X | Standard Language Pack |
| A Option | AZ | AK-LonWorks MCA 107 |
| B Option | BX | No B Option |
| C0 Option MCO | CX | No C0 option |
| C1 Option | X | No C1 option |
| C Option Software | XX | No software option |
| D Option | D0 | 24V DC backup |
| Frame Size | D5H | |
| Power 110% (NO) [KW] | 110 | |
| Height [mm] | 1324,0 | |
| Width w/ no C options [mm] | 325,0 | |
| Depth [mm] | 381,0 | |
| Depth with Option A/B [mm] | 381,0 | |
| kVA | 147 | |
| Power Loss NO [W] | 2555 | |
| Power Loss NO [W] | 2557 | |
| Continuous Current (NO) [A] | 212 | |
| Intermittent Current (NO) [A] | 233 | |
| Continuous Current (NO) [A] | 190 | |
| Intermittent Current (NO) [A] | 209 |
Technical data
| Motor power | 110 kW / 150 HP | |
| Mains voltage | 380 - 480 VAC | |
| Phase | Three-phase | |
| Protection rating | IP21/Type 1+mains shield | |
| Frame size | D5H | |
| RFI filter | Class A2 (EMC C3) | |
| Brake chopper | No | |
| Safe Torque Off | Yes | |
| Control panel | Graphical LCP | |
| PCB coating | Coated PCB | |
| Mains option | Mains Disconnect + Fuse | |
| Fieldbus | AK-LonWorks MCA 107 | |
| Product type | Frequency converter | |
| Continuous output current | 212 A | |
| Continuous current (high line) | 190 A | |
| Intermittent output current | 233 A | |
| Apparent power | 147 kVA | |
| Power loss | 2555 W | |
| Power, normal overload | 110 kW | |
| Height | 1324 mm | |
| Width | 325 mm | |
| Depth | 381 mm | |
| Depth with A/B options | 381 mm | |
| Net weight | 166 kg | |
| Gross weight | 166.3 kg | |
| EAN | 5710108232894 | |
| ECCN (EU) | Y901 | |
| ECCN (US) | 3A999.a | |
Documents
Operating guides, design guides, certificates and CAD drawings for 135N7147 are available on request. Ask for documents →
Other 110 kW / 150 HP variants in VLT Refrigeration Drive FC 103
- 132N7175 IP20 · Class A2 · D3H
- 167F1096 IP20 · Class A2 · D3H
- 132H6990 IP20 · Class A2 · D3H
- 132H0135 IP20 · Class A2 · D3H
- 136X1412 IP20 · Class A2 · D3H
- 134L1400 IP20 · Class A2 · D3H
- 134N9770 IP20 · Class A2 · D3H
- 134X5251 IP20 · Class A2 · D3H
- 134U5069 IP20 · Class A2 · D3H
- 137X9581 IP20 · Class A2 · D3H
- 137U0770 IP20 · Class A2 · D3H
- 134U7442 IP20 · Class A2 · D3H
- 137X8903 IP20 · Class A2 · D3H
- 134N6223 IP20 · Class A2 · D3H
- 132N5863 IP20 · Class A2 · D3H
- 132N8135 IP20 · Class A2 · D3H
- 134N0960 IP20 · Class A2 · D3H
- 136X1034 IP20 · Class A2 · D3H
- 135X5112 IP20 · Class A2 · D3H
- 134L5164 IP20 · Class A2 · D3H
- 134U5068 IP20 · Class A2 · D3H
- 136U8925 IP20 · Class A2 · D3H
- 136U3565 IP20 · Class A2 · D3H
- 134H1341 IP20 · Class A2 · D3H