Danfoss VLT AutomationDrive FC 302 FC-302N132T5E5MH2BGRJXXSXXXXANBRCXXXXD0
135N8435

Danfoss 135N8435 - VLT AutomationDrive FC 302 (132 kW / 200 HP, IP54, 380-500V)

  • Frequency converter
  • VLT® AutomationDrive FC-302
  • (N132) 132 KW / 200 HP,
  • Three phase, 380 - 500 VAC,IP54/Type 12+main shield
  • RFI Filter
  • Brake chopper
  • Graphical Loc. Cont. Panel
  • Coated PCB 3C3 + Ruggedised, Circuit Breaker + Fuse
  • Latest release std. SW.
  • Frame: D6H
  • EtherNet/IP MCA 121, MCB-102 Encoder Option
  • No C1 option, MCB-107 24V DC backup
Model code:
FC-302N132T5E5MH2BGRJXXSXXXXANBRCXXXXD0
Similar products
  • Genuine Danfoss products
  • Danfoss manufacturer warranty
  • Reply within one business day

Product details

Product GroupFC-VLT® AutomationDrive FC-
Series302
Power RatingN132(N132) 132 KW / 200 HP
PhaseTThree phase
Mains Voltage5380 - 500 VAC
EnclosureE5MIP54/Type 12+main shield
RFI FilterH2RFI Filter
Brake - Safe StopBBrake chopper
LCPGGraphical Loc. Cont. Panel
Coating PCBRCoated PCB 3C3 + Ruggedised
Mains OptionJCircuit Breaker + Fuse
Adaptation AXStandard Cable Entries
Adaptation BXNo adaptation
Software ReleaseSXXXLatest release std. SW.
Software Language PackXStandard Language Pack
A OptionANEtherNet/IP MCA 121
B OptionBRMCB-102 Encoder Option
C0 Option MCOCXNo C0 option
C1 OptionXNo C1 option
C Option SoftwareXXNo software option
D OptionD0MCB-107 24V DC backup
Frame SizeD6H
Power 150% (HO) [KW]132
Power 110% (NO) [KW]160
Height [mm]1663,0
Width w/ no C options [mm]325,0
Depth [mm]381,0
Depth with Option A/B [mm]381,0
kVA180
Power Loss NO [W]3770
Power Loss NO [W]3628
Power Loss HO [W]2923
Power Loss HO [W]2689
Continuous Current (NO) [A]315
Intermittent Current (NO) [A]346
Continuous Current (NO) [A]302
Intermittent Current (NO) [A]332
Continuous Current (HO) [A]260
Intermittent Current (HO) [A]390
Continuous Current (HO) [A]240
Intermittent Current (HO) [A]360

Technical data

Motor power132 kW / 200 HP
Mains voltage380 - 500 VAC
PhaseThree-phase
Protection ratingIP54/Type 12+main shield
Frame sizeD6H
RFI filterClass A2 (EMC C3)
Brake chopperYes
Safe Torque OffYes
Control panelGraphical LCP
PCB coatingCoated PCB 3C3 + Ruggedised
Mains optionCircuit Breaker + Fuse
FieldbusEtherNet/IP MCA 121
Product typeFrequency converter
Continuous output current315 A
Continuous current (high line)302 A
Intermittent output current346 A
Continuous current (high overload)260 A
Apparent power180 kVA
Power loss3770 W
Power, normal overload160 kW
Power, high overload132 kW
Height1663 mm
Width325 mm
Depth381 mm
Depth with A/B options381 mm
Net weight62 kg
Gross weight62.3 kg
EAN5710108246198
ECCN (EU)Y901
ECCN (US)3A999.a

Documents

Operating guides, design guides, certificates and CAD drawings for 135N8435 are available on request. Ask for documents →

Other 132 kW / 200 HP variants in VLT AutomationDrive FC 302

Request a quote

Price and delivery time, usually within one business day.